Pella 802Q0102 User manual

Part Number: 802Q0102© 2012 Pella Corporation
INSTALLATION INSTRUCTIONS
SLIDING, SINGLE-HUNG and FIXED WINDOW
WITH FINS
Installation Instructions for Typical Wood Frame Construction.
These instructions were developed and tested for use with typical wood frame wall
construction in a wall system designed to manage water. These instructions are not to
be used with any other construction method. Installation instructions for use with other
construction methods or multiple units may be obtained from Pella Corporation or a local
Pella retailer. Building designs, construction methods, building materials, and site conditions
unique to your project may require an installation method different from these instructions and
additional care. Determining the appropriate installation method is the responsibility of you,
your architect, or construction professional.
Always read the Pella Impervia Limited Warranty before purchasing or installing
Pella Impervia products. By installing this product, you are acknowledging that this Limited
Warranty is part of the terms of the sale. Failure to comply with all Pella Impervia installation and
maintenance instructions may void your Pella Impervia product warranty. See Limited Warranty
for complete details on http://warranty.pellaimpervia.com.
Top
Flashing
Tape
Nailing Fin
Sill Flashing Tape #2
Sill Flashing Tape #1
Side
Flashing
Tape
Weep
Valves
Weather Resistive Barrier
Sheathing
Framing
Side
Flashing
Tape
Corner
Flashing
Tape
Corner
Flashing
Tape
YOU WILL NEED TO SUPPLY:
Ř&HGDURU,PSHUYLRXVVKLPVVSDFHUVWR
ŘJDOYDQL]HGURRŵQJQDLOVOE
Ř&ORVHGFHOOIRDPEDFNHUURGVHDODQWEDFNHU
WRIW
Ř3HOODp6PDUW)ODVKŠIRLOEDFNHGEXW\OZLQGRZ
and door flashing tape or equivalent
Ř3HOOD:LQGRZDQG'RRU,QVWDOODWLRQ6HDODQWRU
equivalent high quality, multi-purpose sealant
WXEHSHUZLQGRZ
Ř/RZH[SDQVLRQORZSUHVVXUHSRO\XUHWKDQHLQVXODWLQJ
window and door foam sealant - DO NOT use high
SUHVVXUHRUODWH[IRDPV
TOOLS REQUIRED:
Ř7DSHPHDVXUH
Ř/HYHO
Ř6TXDUH
Ř+DPPHU
Ř6WDSOHU
Ř6HDODQWJXQ
Ř6FLVVRUVRUXWLOLW\NQLIH
Ř6PDOOŶDWEODGHVFUHZGULYHU
Ř5XEEHUPDOOHW
Installation will require two or more persons for safety reasons.
4&"-"/5
4&"-"/5
REMEMBER TO USE APPROPRIATE
PERSONAL PROTECTIVE EQUIPMENT

A. Confirm the opening is plumb and level.
Note: It is critical the bottom is level.
B. Confirm the window will fit the opening. Measure all
IRXUVLGHVRIWKHRSHQLQJWRPDNHVXUHLWLVODUJHU
than the window in both width and height. On larger
openings measure the width and height in several places
to ensure the header or studs are not bowed.
Note: 1-1/2" or more of solid wood blocking is
required around the perimeter of the opening. Fix any
problems with the rough opening before proceeding.
C. Cut the water resistive barrier.
D. Fold the water resistive barrier. Fold side flaps into
the opening and staple to the inside wall. Fold the top
flap up and temporarily fasten with flashing tape.
E. Apply sill flashing tape #1.&XWDSLHFHRIŶDVKLQJ
longer than the opening width. Apply at the bottom of the
RSHQLQJDVVKRZQVRLWRYHUKDQJVWRWKHH[WHULRU
Note: The tape is cut 12" longer than the width of the
opening so it will extend up each side approximately 6".
F. Tab the sill flashing tape and fold.&XWZLGHWDEVDW
HDFKFRUQHUIURPHDFKVLGHRIFRUQHU)ROGWDSH
WRWKHH[WHULRUDQGSUHVVŵUPO\WRDGKHUHLWWRWKHZDWHU
resistive barrier.
G. Apply sill flashing tape #2. Cut a piece of flashing tape
ORQJHUWKDQWKHRSHQLQJZLGWK$SSO\DWWKHERWWRP
RYHUODSSLQJWDSHE\DWOHDVW'2127DOORZWKH
WDSHWRH[WHQGSDVWWKHLQWHULRUIDFHRIWKHIUDPH
Note: The flashing tape does not need to extend all
the way to the interior of the framing.
1F
1"
1/2"
1/2"
6"
1E
1"
1G
Interior
1A
$
Interior
1B
%
TUDVU
OEDVU
SEDVU
8BUFS3FTJTUJWF#BSSJFS
$
UIDVU
.BLFBODVUVQGSPN
FBDIUPQDPSOFSBUB¡
BOHMFUPBMMPXUIFXBUFS
SFTJTUJWFCBSSJFSUPCF
MBQQFEPWFSUIFmOBUUIF
IFBEPGUIFXJOEPX
&
1D
Exterior
'
(
)
*
1ROUGH OPENING
PREPARATION

2A
A. Install and level shims.3ODFHZLGHE\WKLFNVKLPV
RQWKHERWWRPRIWKHRSHQLQJIURPHDFKVLGHEHQHDWK
WUDQVLWLRQEDUVDQGPXOOLRQMRLQWV.HHSVKLPVEDFNIURP
interior face of window. Adjust shims as necessary to ensure the
sill is level. Once level, attach shims to prevent movement.
Note: Improper placement of shims may result in bowing
the bottom of the window.
B. Remove plastic wrap and cardboard packaging from
window. DO NOT open the window until it is fully fastened.
Note: For best results, install the window with the sash
closed and locked with the shipping spacers in place.
TWO OR MORE PEOPLE WILL BE REQUIRED
FOR THE FOLLOWING STEPS.
Note: If fins are to be installed to no fin
units, go to the Applying Installation Fin
instructions on the back before proceeding
to step C.
C. Insert the windowIURPWKHH[WHULRURIWKHEXLOGLQJ
Place the bottom of the window on the spacers at the
bottom of the opening, then tilt the top into position.
Center the window between the sides of the opening to
DOORZFOHDUDQFHIRUVKLPPLQJDQGLQVHUWRQHURRŵQJQDLO
LQWKHŵUVWKROHIURPWKHFRUQHURQHDFKHQGRIWKHWRS
QDLOLQJŵQ7KHVHDUHXVHGWRKROGWKHZLQGRZLQSODFH
while shimming it plumb and square.
D. Plumb and square window.3ODFHVKLPVIURPWKH
bottom and top of the window between the window and
WKHVLGHVRIWKHRSHQLQJ.HHSVKLPVEDFNIURP
interior face of window. Adjust the shims as required to
plumb and square the window in the opening. If the frame
KHLJKWH[FHHGVSODFHVKLPVDWWKHTXDUWHUSRLQWVRI
the window sides.
Note: DO NOT shim above the window or in the space
between the spacers at the bottom of the window. DO
NOT over shim.
E. Check the interior reveal. Make sure the measurement from
the interior face of the window to the interior face of the wall is
equal at several points around the window.
F. Fasten the window to openingE\GULYLQJJDOYDQL]HG
URRŵQJQDLOVLQWRHDFKSUHSXQFKHGKROHLQWKHQDLOLQJŵQ
G. Check the window operation.5HPRYHWKHSODVWLF
spacers located between the bottom of the vent panel and
the frame sill. Open and close the window a few times to
check for proper operation. Close and lock the window.
Note: If there are any problems with the operations
of the window, recheck shim locations and adjust for
plumb and square.
2C
Interior View
2D
2D
2E
2E
1
20 30 40 50 60 70
23
INCHES
mm
$
&
'
'
(
(
2
SETTING AND FASTENING THE WINDOW

A. Apply side flashing tape. Cut two pieces of flashing
WDSHORQJHUWKDQWKHIUDPHKHLJKWRIWKHZLQGRZ
$SSO\RQHSLHFHWRHDFKVLGHRQWRWKHIUDPH
RYHUWKHQDLOLQJŵQDQGRQWRWKHZDWHUUHVLVWLYH
EDUULHU7KHWDSHVKRXOGH[WHQGDERYHWKHWRSRI
WKHZLQGRZDQGEHORZWKHERWWRPRIWKHZLQGRZ
3UHVVWKHWDSHGRZQŵUPO\ZKLOHIROGLQJGRZQWKH
H[FHVVWDSHDWWKHWRSDQGERWWRPRIWKHZLQGRZ
B. Apply top flashing tape. Cut a piece of flashing tape
long enough to go across the top of the window and
H[WHQGDWOHDVWSDVWWKHVLGHIODVKLQJWDSHRQERWK
VLGHV$SSO\WKHWDSHRQWRWKHIUDPHRYHUWKH
top nailing fin as shown. Fold the overlapping tape
down, and press all tape down firmly.
Note: DO NOT tape or seal the bottom nailing fin.
C. Fold down top flap of the water resistive barrier.
D. Apply flashing tape to diagonal cuts. Cut pieces of
IODVKLQJWDSHDWOHDVWORQJHUWKDQWKHGLDJRQDOFXWV
in the water resistive barrier. Apply the tape covering
the entire diagonal cut in the water resistive barrier at
both upper corners of the window.
Note: Be sure to overlap the top corners.
Caution: Ensure use of low pressure polyurethane window and door insulating foams
and strictly follow the foam manufacturer’s recommendations for application. Use
of high pressure foams or improper application of the foam may cause the window
frame to bow and hinder operation.
A. Apply insulating foam sealant. From the interior, insert
WKHQR]]OHRIWKHDSSOLFDWRUDSSUR[LPDWHO\GHHSLQWR
the space between the window and the rough opening
DQGDSSO\DGHHSEHDGRIIRDP7KLVZLOODOORZURRP
IRUH[SDQVLRQRIWKHIRDPDQGZLOOPLQLPL]HVTXHH]H
out. Apply sealant across interior surface of shims
to create a continuous seal. For windows with jamb
H[WHQVLRQVLQVWDOOHGHQVXUHWKHIRDPLVSODFHGEHWZHHQ
the window frame and the rough opening, not between
WKHMDPEH[WHQVLRQDQGWKHURXJKRSHQLQJ)ROORZIRDP
manufacturer's instructions.
Note: It may be necessary to squeeze the end of the tube with pliers to be able to
insert into the space between the window frame and the rough opening. DO NOT
completely fill the space from the back of the fin to the interior face of the opening.
B. Check window operationYHQWXQLWVRQO\E\RSHQLQJDQGFORVLQJWKHZLQGRZ
Note: If the window does not operate correctly, check to make sure it is still plumb,
level, square and that the sides are not bowed. If adjustments are required, remove the
foam with a serrated knife. Adjust the shims, and reapply the insulating foam sealant.
Interior View
4A
3A
3B
#
3C
3D
3D
$
%
%
'
'
&
$
3INTEGRATING THE WINDOW TO THE WATER
RESISTIVE BARRIER
4
INTERIOR SEAL

When applying siding, brick veneer or other exterior finish material, leave adequate
space between the window frame and the material for sealant. Refer to the illustration
corresponding to your finish material.
Note: The sealant details shown are standard recommendations from the sealant industry.
Contact your sealant supplier for recommendations and instructions for these and any
other applications.
A. Insert closed cell foam backer rod into the space
around the window as deep as it will go. This should
SURYLGHDWOHDVWDŔFOHDUDQFHEHWZHHQWKHEDFNHU
URGDQGWKHH[WHULRUIDFHRIWKHZLQGRZ
Note: Backer rod adds shape and depth for the
sealant line.
B. Apply a bead of high quality exterior grade
sealant to the entire perimeter of the window.
C. Shape, tool and clean excess sealant. When
ŵQLVKHGWKHVHDODQWVKRXOGEHWKHVKDSHRIDQKRXUJODVV
Note: This method creates a more flexible sealant line capable
of expanding and contracting.
5A
5B
VINYL/STEEL
SIDING
Insulate
and seal
Backer rod
and
sealant
typical
Sealant
typical
Insulate
and seal
BRICK VENEER
Backer rod
and
sealant
typical
Insulate
and seal
1/4"
1/4"
min.
WOOD
SIDING
1/4"
1/4"
min.
1/8"
STUCCO WITH
INSULATION BOARD
SOUTHWESTERN WALL
WITH STUCCO
1/4"
1/4"
min.
1/4"
1/4"
min.
$ %
5SEALING THE WINDOW TO THE
EXTERIOR WALL CLADDING

APPLYING INSTALLATION FINS
$ 6OLGHWKHSUHFXWERWWRPŵQLQWRWKH
frame sill groove located on the
bottom window frame member.
Frame
sill groove
Frame jamb groove
Frame head groove
C
B
B
A
% ,QVWDOOWKHSUHFXWVLGHŵQV
into the top of the frame jamb
grooves located on the side frame
members of the window. Slide the
ŵQVLQWRSODFH
Note: The side fins must overlap
the exterior of the bottom fin.
C. Install and slide the precut top
ŵQLQWRWKHIUDPHKHDGJURRYH
located in the top frame member.
Note: The top fin must overlap
the exterior of the side fins.
' 6HDOWKHRYHUODSSLQJŵQMRLQWVZLWKVHDODQW
TO INSTALL THE WINDOW(S) PROCEED TO STEP 2C.
B
B
C
A

FINISH
7KHLQWHULRUDQGH[WHULRUIUDPHDQGVDVKDUHSURWHFWHGE\DSRZGHUFRDWEDNHGRQIDFWRU\ŵQLVK
that requires no painting. Clean this surface with mild soap and water. Stubborn stains and
deposits may be removed with mineral spirts. DO NOT use abrasives. DO NOT scrape or use tools
that might damage the surface.
Use of inappropriate solvents, brickwash or cleaning chemicals will cause adverse reactions with
window and door materials and voids the Limited Warranty.
CARE AND MAINTENANCE
Care and maintenance information is available by contacting your local Pella retailer. This
information is also available at www.pellaimpervia.com.
IMPORTANT NOTICE
%HFDXVHDOOFRQVWUXFWLRQPXVWDQWLFLSDWHVRPHZDWHULQŵOWUDWLRQLWLVLPSRUWDQWWKDWWKHZDOOV\VWHP
be designed and constructed to properly manage moisture. Pella Corporation is not responsible
IRUFODLPVRUGDPDJHVFDXVHGE\DQWLFLSDWHGDQGXQDQWLFLSDWHGZDWHULQŵOWUDWLRQGHŵFLHQFLHVLQ
EXLOGLQJGHVLJQFRQVWUXFWLRQDQGPDLQWHQDQFHIDLOXUHWRLQVWDOO3HOODpproducts in accordance
ZLWK3HOODLQVWDOODWLRQLQVWUXFWLRQVRUWKHXVHRI3HOODSURGXFWVLQZDOOV\VWHPVZKLFKGRQRWDOORZ
for proper management of moisture within the wall systems. The determination of the suitability of
all building components, including the use of Pella products, as well as the design and installation
of flashing and sealing systems are the responsibility of the Buyer or User, the architect, contractor,
installer, or other construction professional and are not the responsibility of Pella.
Pella products should not be used in barrier wall systems which do not allow for proper
PDQDJHPHQWRIPRLVWXUHZLWKLQWKHZDOOV\VWHPVVXFKDVEDUULHU([WHULRU,QVXODWLRQDQG)LQLVK
6\VWHPV(,)6DOVRNQRZQDVV\QWKHWLFVWXFFRRURWKHUQRQZDWHUPDQDJHGV\VWHPV([FHSW
LQWKHVWDWHVRI&DOLIRUQLD1HZ0H[LFR$UL]RQD1HYDGD8WDKDQG&RORUDGRPella makes no
warranty of any kind and assumes no responsibility for Pella windows and doors installed
in barrier wall systems. In the states listed above, the installation of Pella products in barrier
wall or similar systems must be in accordance with Pella installation instructions.
3URGXFWPRGLŵFDWLRQVWKDWDUHQRWDSSURYHGE\3HOOD&RUSRUDWLRQZLOOYRLGWKH/LPLWHG:DUUDQW\
Table of contents
Other Pella Household Appliance manuals

Pella
Pella 812W0100 User manual

Pella
Pella 80GZ0102 User manual

Pella
Pella 80AT0102 User manual

Pella
Pella 80WW0101 Guide

Pella
Pella 816G0101 User manual

Pella
Pella 802X0104 User manual

Pella
Pella HURRICANESHIELD 80GY0102 User manual

Pella
Pella 80YW0102 Guide

Pella
Pella 81CP0101 User manual

Pella
Pella HURRICANESHIELD 80ED0101 User manual