manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pentair
  6. •
  7. Control System
  8. •
  9. Pentair EasyTouch User manual

Pentair EasyTouch User manual

Other manuals for EasyTouch

1

This manual suits for next models

3

Other Pentair Control System manuals

Pentair SCREENLOGIC INTERFACE User manual

Pentair

Pentair SCREENLOGIC INTERFACE User manual

Pentair Intellitouch ScreenLogic User manual

Pentair

Pentair Intellitouch ScreenLogic User manual

Pentair EasyTouch Pool/Spa Control System LX-100EZ Installation instructions

Pentair

Pentair EasyTouch Pool/Spa Control System LX-100EZ Installation instructions

Pentair INTELLITOUCH User manual

Pentair

Pentair INTELLITOUCH User manual

Pentair IntelliSync 523404 User manual

Pentair

Pentair IntelliSync 523404 User manual

Pentair Pool and Spa Control System SunTouch User manual

Pentair

Pentair Pool and Spa Control System SunTouch User manual

Pentair SunTouch User manual

Pentair

Pentair SunTouch User manual

Pentair EasyTouch 8 and 4 User manual

Pentair

Pentair EasyTouch 8 and 4 User manual

Pentair Hypro ProStop-E Quad 4216N-3404VPSQ User manual

Pentair

Pentair Hypro ProStop-E Quad 4216N-3404VPSQ User manual

Pentair PENTEK DEFENDER CSC-LINK User manual

Pentair

Pentair PENTEK DEFENDER CSC-LINK User manual

Pentair EASYTOUCH PL4 User manual

Pentair

Pentair EASYTOUCH PL4 User manual

Pentair ProValve User manual

Pentair

Pentair ProValve User manual

Pentair IntelliCenter 522039Z User manual

Pentair

Pentair IntelliCenter 522039Z User manual

Pentair EasyTouch Installation and operation manual

Pentair

Pentair EasyTouch Installation and operation manual

Pentair EasyTouch 8 User manual

Pentair

Pentair EasyTouch 8 User manual

Pentair INTELLICENTER User manual

Pentair

Pentair INTELLICENTER User manual

Pentair INTELLICONNECT User manual

Pentair

Pentair INTELLICONNECT User manual

Pentair SPACOMMAND CP3800 Series User manual

Pentair

Pentair SPACOMMAND CP3800 Series User manual

Pentair INTELLICENTER User manual

Pentair

Pentair INTELLICENTER User manual

Pentair SunTouch User manual

Pentair

Pentair SunTouch User manual

Pentair AUTOTROL 460i User manual

Pentair

Pentair AUTOTROL 460i User manual

Pentair IntelliSync 523404 User manual

Pentair

Pentair IntelliSync 523404 User manual

Pentair EASYTOUCH PL4 User manual

Pentair

Pentair EASYTOUCH PL4 User manual

Pentair INTELLICENTER User manual

Pentair

Pentair INTELLICENTER User manual

Popular Control System manuals by other brands

Comunello BORDER 400 Installation and user manual

Comunello

Comunello BORDER 400 Installation and user manual

Verlinde EUROBLOC Variator VTN Service manual

Verlinde

Verlinde EUROBLOC Variator VTN Service manual

Diginet DGOZ-TCSW-LR35 installation guide

Diginet

Diginet DGOZ-TCSW-LR35 installation guide

VADDIO ControlVIEW Xtreme manual

VADDIO

VADDIO ControlVIEW Xtreme manual

Duke HSHU 13 SERIES Installation and operation manual

Duke

Duke HSHU 13 SERIES Installation and operation manual

AIRTRONICS Blazer Sport manual

AIRTRONICS

AIRTRONICS Blazer Sport manual

Pentair Pool Products Compool Installation and user guide

Pentair Pool Products

Pentair Pool Products Compool Installation and user guide

ComfortNET CTK04 manual

ComfortNET

ComfortNET CTK04 manual

CAME G3000 installation manual

CAME

CAME G3000 installation manual

Idemia MorphoAccess VP MD installation guide

Idemia

Idemia MorphoAccess VP MD installation guide

Doosan DVF Series Operation user's manual

Doosan

Doosan DVF Series Operation user's manual

Axis P1445-LE-3 user manual

Axis

Axis P1445-LE-3 user manual

CNC-Step High-Z T-Series operating instructions

CNC-Step

CNC-Step High-Z T-Series operating instructions

Honeywell KAP 140 Maintenance manual

Honeywell

Honeywell KAP 140 Maintenance manual

Honeywell vk41 series Handbook

Honeywell

Honeywell vk41 series Handbook

Cypress HHR-3160 product manual

Cypress

Cypress HHR-3160 product manual

Zonex GEN II -VVT Installation and application manual

Zonex

Zonex GEN II -VVT Installation and application manual

Altronics K 9650 quick start guide

Altronics

Altronics K 9650 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

EASYTOUCH®/ INTELLITOUCH®
CONTROL SYSTEM UPGRADE
TO INTELLICENTER™ CONTROL SYSTEM
(For Systems 2012 or Newer)
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
INSTALLATION GUIDE
Pool Spa Features Lights
Air Temp 65° F
Schedule Usage Chemistry Status
3 3
8:00 A.M.
6.50
0
4
84°
78°
ii
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
P/N 523455 Rev. A 10/2019
Contents
IMPORTANT WARNING AND SAFETY INSTRUCTIONS......................................................................ii-vi
OVERVIEW / SUMMARY .....................................................................................................................1-2
BOX CONTENTS ..................................................................................................................................... 3
REMOVING THE EXISTING OUTDOOR CONTROL PANEL............................................................ 4
INSTALL THE NEW 4A AND 5A LOW VOLTAGE CIRCUIT BREAKERS AND SYSTEM
TRANSFORMER ..................................................................................................................................6-9
INSTALLING THE INTELLICENTER CONTROL SYSTEM OUTDOOR CONTROL PANEL....... 10
CONNECTING AND CONFIGURING POOL AND SPA EQUIPMENT .......................................... 10
INSTALLING THE WIRING LABEL ON THE ENCLOSURE FRONT DOOR................................. 11
Note: INSTALLING THE WIRELESS ANTENNA KIT.
(See IntelliCenter Control System Installation Guide).
Customer Service
8 AM to 5.30 PM — Eastern and Pacific Times
Phone: (800) 831-7133
Fax: (800) 284-4151
Visit www.pentair.com
Technical Support
Sanford, North Carolina (8 A.M. to 8.30 PM ET)
Phone: (919) 566-8000
Fax: (919) 566-8920
Moorpark, California (8 A.M. to 5.30 PM PT)
Phone: (805) 553-5000 (Ext. 5591)
Fax: (805) 553-5515
CUSTOMER SERVICE /TECHNICAL SUPPORT
General Installation Information
1. All work must be performed by a licensed electrician, and must conform to all national, state, and local
codes.
2. Install to provide drainage of compartment for electrical components.
3. If this system is used to control underwater lighting fixtures, a ground-fault interrupter (GFCI) must be
provided for these fixtures. Conductors on the load side of the ground-fault circuit-interrupter shall not
occupy conduit, junction boxes or enclosures containing other conductors unless such conductors are
also protected by a ground-fault circuit-interrupter. Refer to local codes for details.
4. A terminal bar stamped is located inside the supply terminal box.To reduce the risk of electric
shock, this terminal must be connected to the grounding means provided in the electric supply service
panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment
(no smaller than 12 AWG or 3.3 mm). The bonding lug(s) provided on this unit are intended to connect
a minimum of one No. 8 AWG for US installation and two No. 6 AWG for Canadian installations solid
copper conductor between this unit and any metal equipment, metal enclosures or electrical equipment,
metal water pipe, or conduit within 5 feet (1.5 m) of the unit.
5. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all
ungrounded supply conductors to comply with in accordance with the current National Electrical Code
(NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installation
codes and ordinances must also be adhered to. The disconnecting means must be readily accessible to
the tub occupant but installed at least 10 ft. (3.05 m) from the inside wall of the pool.
6. GAS HEATER: This automation control system is designed to supply high voltage (120 VAC / 240 VAC)
to a gas heater and override the thermostat in the heater’s control circuit.This automation control
system is intended to control gas heaters with a high temperature limit switch(s) safety circuit.
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
iii
This product is designed and manufactured for safe and reliable service when installed, operated and
maintained according to the information and installation codes referred to in this Guide.
Risk of Electrical Shock or Electrocution!
- Always disconnect power at the circuit breaker before servicing the load center.
Improper installation can create an electrical shock hazard that can result in death or
serious injury.
This product must be installed by a licensed or certified electrician or a qualified pool
professional in accordance with the current National Electrical Code (NEC), NFPA 70
or the Canadian Electrical Code (CEC), CSA C22.1. All applicable local installation
codes and ordinances must also be adhered to. Improper installation will create an
electrical hazard which could result in death or serious injury to pool users, installers
or others due to electrical shock, and may also cause damage to property. Always
disconnect the power to the pool light at the circuit breaker before servicing the light. Failure to do so
could result in death or serious injury to serviceman, pool users or others due to electrical shock.
READ AND FOLLOW ALL WARNING AND SAFETY INSTRUCTIONS
SERIOUS BODILY INJURY OR DEATH CAN RESULT IFTHIS PRODUCT (UNIT) IS NOT
INSTALLED AND USED CORRECTLY.
INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READTHESE
WARNINGS AND ALL INSTRUCTIONS BEFORE USINGTHIS PRODUCT.This Guide pro-
vides installation and operation instructions for the product. Consult Pentair
Water Pool and Spa, Inc. (“Pentair”) with any questions regarding this
product.
This product is intended for use in swimming pool applications only.
Most states and local codes regulate the construction, installation, and operation of public pools and spas, and
the construction of residential pools and spas. It is important to comply with these codes, many of which directly
regulate the installation and use of this product. Consult your local building and health codes for more information.
This guide provides installation and operation instructions for the IntelliCenter™Control System. Consult
Pentair Water Pool and Spa, Inc. with any questions regarding this equipment (see “Customer Service/Technical
Support”, page ii).
Attention Installer: This guide contains important information about the installation,
operation and safe usage of this product. Give this guide to the owner and/or operator of this equipment after
installation.
Attention User: This manual contains important information that will help you in operating and maintaining this
filter. Please save it for future reference.
Attention User: This Guide contains important information that will help you in operating and maintaining this
product. Please retain it for future reference. Read the entire Installation Guide and all related warning labels
before installing this product or attempting to use, service or adjust the IntelliCenter® Control System. Read the op-
erating instructions and warnings for all equipment in the pool circulating system before operating. Failure to follow
safety warnings and instructions can result in severe injury, death, or property damage.
Call (800) 831-7133 for additional free copies of this Guide or replacement safety labels.
This is a safety alert symbol. When you see this symbol in this manual or on the product, look for one of
the following signal words; DANGER, WARNING, CAUTION and NOTICE and comply with the information.
Be alert to the potential hazard. Ensure to read and comply with all of the warnings and cautions in this
manual.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
iv
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
Water temperature in excess of 100° F (37.7° C) may be hazardous to your health.
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs
when the internal temperature of the body reaches a level several degrees above normal
body temperature of 98.6° F (37° C.). Effects of hyperthermia include: (1) Unawareness
of impending danger. (2) Failure to perceive heat.(3) Failure to recognize the need to
leave the spa. (4) Physical inability to exit the spa. (5) Fetal damage in pregnant women.
(6) Unconsciousness resulting in danger of drowning.The use of alcohol, drugs, or
medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas.
A pool or spa pump must be installed by a qualified pool and spa service professional in
accordance with the current National Electrical Code and all applicable local codes and
ordinances. Improper installation may create an electrical hazard which could result in
death or serious injury to pool users, installers, or others due to electrical shock, and may
also cause damage to property.
The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia
in hot tubs and spas.This product is intended to control heaters with built-in high limit circuits
ONLY. Failure to do so may cause property damage or personal injury.
Do not use this product to control an automatic pool cover. Swimmers may become entrapped
underneath the cover.
For units intended for use in other than single-family dwellings, a clearly labeled
emergency switch shall be provided as part of the installation. The switch shall be readily
accessible to the occupants and shall be installed at least five (5) feet (1.52 m) away, adjacent
to, and within sight of, the unit.
Except for listed spa-side remote controls, install a minimum of five (5) feet (1.52 m) from the
inside wall of the pool and spa.
For information about the Virginia Graeme Baker Pool and Spa Safety Act, contact the Consumer Product Safety
Commission at (301) 504-7908 or visit www.cpsc.gov.
NOTE: Always turn off all power to the pool pump before installing the cover or working on any suction outlet.
Two Speed Pump Controls Notice (Title 20 Compliance)
Please read the following important Safety Instructions - When using two-speed pumps manufactured
on or after January 1, 2008, the pump’s default circulation speed MUST be set to the LOWEST SPEED, with
a high speed override capability being for a temporary period not to exceed one normal cycle, or two hours,
whichever is less.
The electrical supply for this product must include a suitably rated switch or circuit breaker
to open all ungrounded supply conductors to comply with the current National Electrical
Code (NEC), NFPA 70 or the Canadian Electrical Code (CEC), CSA C22.1. All applicable
local installation codes and ordinances must also be adhered to. The disconnecting
means must be readily accessible to the tub occupant but installed at least five 5ft. (1.52
m), (Canada 3 m (9.75 ft) from the inside wall of the pool.
Use only copper supply conductor’s rated for 60C/75C sized based on ampacity to
support all loads (refer to NEC tables). Load center input supply to be protected by
150 Amp Maximum, 240 VAC Main Circuit Breaker.
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
v
IMPORTANT WARNING AND SAFETY INSTRUCTIONS
Canada - Industry Canada (IC) - The IntelliCenter Control System complies with RSS210 of Industry Canada. (1999).
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause undesired operation of the device.
The device complies with industry Canada’s License Exempt RSSs. Operation is subject to the following: (1) This device
may not cause interference; and (2) This device must accept interference that may cause undesired operation of the
device.
Le dispositif est conforme à la licence d’Industrie Canada Exempt CNR.Le fonctionnement est soumis à la suivante.
(1) Ce ne doit pas provoquer d’interférences ; et (2) Cet appareil doit accepter les interférences qui peuvent causer un
mauvais fonctionnement de l’appareil.
This Class B digital apparatus complies with Canadian ICES-003.Cet appareil numérique de la classe B est conforme à
la norme NMB-003 du Canada.The term “IC” before the certification / registration number only signifies that the Industry
Canada technical specifications were met.
FCC Regulatory Safety Notice
FCC non-modification statement:
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
FCC RF Exposure requirements:
FCC Standard - 47 CFR Part 15, Subpart C (Section 15.247).This version is limited to chapter 1 to chapter 11 by specified
firmware controlled in the U.S.A.
Notice: In order to comply with FCC RF Exposure requirements, a minimum separation distance of 8 in (20 cm) must be
maintained between the equipment and all persons during normal operation.
Instruction to user - The IntelliCenter™ Control System device has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful
interference in a residential installation. The IntelliCenter Control System generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this device does cause harmful
interference to radio or television reception, which can be determined by switching the device off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Note: The user is cautioned that changes and modifications made to the IntelliCenter Control System without the approval of the
manufacturer could void the user’s authority to operate this equipment.
Industry Canada (IC) Regulatory Notice – RSS210:
InstructionTo User: This device complies with RSS210 of Innovation, Science and Economic Development Canada (ISED). Under
ISED regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for
the transmitter by ISED.To reduce potential radio interference to other users, the antenna type and its gain should be so chosen
that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.This device
complies with Innovation, Science and Economic Development Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions:(1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Conformément à la réglementation d’Innovation, Sciences et Developpment Economique Canada (ISED), le présent émetteur radio
peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par ISED. Dans le but
de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain
vi
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
Qualifications for Installers and Users
This product must be installed by a qualified pool technician in accordance with all applicable
local codes and ordinances.It must be serviced by someone who fully understands its operation.
Improper installation or servicing could result in death or serious injury to pool users, installers,
servicers, or others and may also cause damage to property.
If you are not familiar with your pool filtering system and/or heater, do NOT attempt to adjust or
service without consulting your dealer or a qualified pool technician.
Do not permit children to use this product.
Pentair Water Pool and Spa
IMPORTANT SAFETY INSTRUCTIONS
For Installation of Electrical Controls at Equipment Pad
(ON/OFF Switches,Timers, and Automation Control Systems)
Install all electrical controls at equipment pad, such as on/off switches, timers,
and control systems, etc. to allow the operation (start-up, shut-down, or
servicing) of any pump or filter so the user does not place any portion of his/
her body over or near the pump strainer lid, filter lid or valve closures. This
installation should allow the user enough space to stand clear of the filter and
pump during system start-up, shut down or servicing of the system filter.
HAZARDOUS PRESSURE: STAND CLEAR OF PUMP AND FILTER
DURING START-UP
CAUTION! INSTALL POWER CENTERTO ALLOW USER ENOUGH SPACETO
STAND CLEAR OF PUMP AND FILTER WHEN SERVICING.
1
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
Overview
This manual describes how to upgrade an EasyTouch or IntelliTouch Control System to the IntelliCenter
Control System.
The Upgrade Installation Kits apply to the following:
• EasyTouch®PL4/PSL4 Control Systems, EasyTouch®Control Systems
• IntelliTouch®Control Systems
Systems using the following Load Center or Power Center use the following kit part numbers:
• 2012 or newer (square low voltage circuit breaker configuration)
• P/N 522047 for i10P
• P/N 522048 for i10PS
• P/N 523049 for i10D
• System must be marked as UL listed/certified
EasyTouch®and IntelliTouch®Control System
Upgrade Installation Kits
IntelliCenter™ Control System Outdoor Control Panel
Pool Spa Features Lights
Air Temp 65° F
Schedule Usage Chemistry Status
3 3
8:00 A.M.
6.50
0
4
84°
78°
IntelliCenter Control System Outdoor Control Panel for EasyTouch or IntelliTouch Load Center or Power Center
2
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
IntelliCenter™ Control System Installation Instructions Summary
Required Tools:
• Medium size flat blade screwdriver or 1/4” and 5/16” sockets
• Needle nose pliers
REMOVING THE EXISTING OUTDOOR CONTROL PANEL............................................................ 4
INSTALL THE NEW 4A AND 5A LOW VOLTAGE CIRCUIT BREAKERS AND SYSTEM
TRANSFORMER ..................................................................................................................................6-9
INSTALLING THE INTELLICENTER CONTROL SYSTEM OUTDOOR CONTROL PANEL....... 10
CONNECTING AND CONFIGURING POOL AND SPA EQUIPMENT .......................................... 10
INSTALLING THE WIRING LABEL ON THE ENCLOSURE FRONT DOOR................................. 11
Note: INSTALLING THE WIRELESS ANTENNA KIT. See IntelliCenter Control System
Installation Guide.
CAUTION: If there are EasyTouch or IntelliTouch Control System installed accessories, such as an
Indoor Control Panel or Wireless Remote, they will no longer function after installing the IntelliCenter
Control System Upgrade Kit.In addition to the free IntelliCenter Control System phone app, the following
optional accessories can also be purchased.
• IntelliCenter Indoor Control Panel, White Faceplate - P/N 522035
• IntelliCenter Indoor Control Panel, Tan Faceplate - P/N 523058.
• IntelliCenter Indoor Control Panel, Black Faceplate - P/N 523059.
• IntelliCenter Wireless Remote with Transceiver -P/N 522036.
3
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
1. P/N 521938, Outdoor Control Panel.
2. Kit P/N 522047: P/N 521993Z, i10P
Personality Board, Shared Equipment.
Kit P/N 522048: P/N 521873Z, i10PS Personality Board,
Shared Equipment.
Kit P/N 523049: P/N 523029Z, i10D Personality
Board, Shared Equipment.
3. (3a) P/N 522338, Circuit Breaker 4 AMP.
(3b) P/N 522339, Circuit Breaker 5 AMP.
4. P/N 521090, Circuit Breaker Plug.
5. P/N 522337, Label Circuit Breaker.
6. P/N 522102, System Transformer.
7. P/N 520222, Six (6) screws.
8. P/N 522475, Wireless Antenna Kit.
9. P/N 522612, Wiring Label, IntelliCenter Control System.
IntelliCenter Control System manuals (not shown):
• Installation Guide (P/N 522989)
• User’s Guide (P/N 522990)
• Quick Reference Guide (P/N 522988)
• Wi-Fi Remote Installation Guide (P/N 523350)
BOX CONTENTS




Kit P/N 522047, 522048, 523049
P/N 522102
SystemTransformer
P/N 522337
Circuit Breaker
Label
P/N 521090
Circuit
Breaker
Plug
(3a) P/N 522338
4 AMP Circuit
Breaker
(3b) P/N 522339
5 AMP Circuit
Breaker
P/N 520222
Six (6) Screws
Outdoor Control Panel
PCBA
i10P / i10PS / i10D



Wireless Antenna Kit P/N 522475
Figure 1. IntelliCenter Control System Upgrade Kits Contents
Wiring Label,
Intellicenter Control System
9.
AUX5 AUX6
AUX7 AUX8 AUX9
*522612*
Wiring Diagram label for IntelliCenter Control System Upgrade Kit.
4
Note: Refer to page 3 where (parts index number) is shown
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
Removing the Existing Outdoor Control Panel
The following upgrade installation instructions are for EasyTouch® PL4/PSL4, EasyTouch or IntelliTouch
Control Systems using the 2012 or later (square low voltage circuit breakers configuration on bezel) Load
Center or Power Center.
1. TURN OFF POWER TO ALL POOL AND SPA EQUIPMENT BEFORE STARTING.
CAUTION! DO NOT PLUG IN OR UNPLUG ANY SYSTEM COMPONENTS WITH THE
POWER ON. THIS MAY DAMAGE THE SYSTEM COMPONENTS.
2. Unlatch the front door latch. Open the door of the Load Center or Power Center.
3. Remove the two screws securing the High Voltage Cover Panel. Remove the panel and set
aside.
4. Loosen the two retaining screws securing the existing control panel. Fold down the panel to
access the circuit board low voltage connections and transformer connector.
Continue to next page
WARNING!
RISK OF ELECTRICAL SHOCK. BEFORE REMOVINGTHE HIGH VOLTAGE
COVER PANEL FROMTHE ENCLOSURE SWITCH OFFTHE
MAIN POWER ATTHE HOME AT THE MAIN CIRCUIT BREAKER BOX.
Figure 2. Load Center or Power Center (2012 or later)
Retaining screw Retaining screw
Bezel screw Bezel screw
High Voltage
Cover Panel
Retaining screws
(for High Voltage Cover
Panel)
Front
door
Three Tabs/Slots