logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Pentair
  6. •
  7. Control Unit
  8. •
  9. Pentair FLECK 125 User manual

Pentair FLECK 125 User manual

Other Pentair Control Unit manuals

Pentair Fleck 9000-SXT User manual

Pentair

Pentair Fleck 9000-SXT User manual

Pentair AURORA CBV-S5 User manual

Pentair

Pentair AURORA CBV-S5 User manual

Pentair SPEEDEO SB-PF-SPO-003C User manual

Pentair

Pentair SPEEDEO SB-PF-SPO-003C User manual

Pentair HYPRO PROSTOP-E User manual

Pentair

Pentair HYPRO PROSTOP-E User manual

Pentair FLECK 5000 User manual

Pentair

Pentair FLECK 5000 User manual

Pentair HYPRO PROSTOP-E User manual

Pentair

Pentair HYPRO PROSTOP-E User manual

Pentair AUTOTROL LOGIX 742 User manual

Pentair

Pentair AUTOTROL LOGIX 742 User manual

Pentair FLECK 5810 User manual

Pentair

Pentair FLECK 5810 User manual

Pentair FLECK 2900S User manual

Pentair

Pentair FLECK 2900S User manual

Pentair ERICO CADWELD PLUS User manual

Pentair

Pentair ERICO CADWELD PLUS User manual

Pentair Fleck 5800 LXT User manual

Pentair

Pentair Fleck 5800 LXT User manual

Pentair Fleck 4600 MECH User manual

Pentair

Pentair Fleck 4600 MECH User manual

Pentair AUTOTROL 604 User guide

Pentair

Pentair AUTOTROL 604 User guide

Pentair AUTOTROL368 User guide

Pentair

Pentair AUTOTROL368 User guide

Pentair Fleck 5800 LXT User guide

Pentair

Pentair Fleck 5800 LXT User guide

Pentair Raychem PMKG-LE User manual

Pentair

Pentair Raychem PMKG-LE User manual

Pentair Fleck 2850 NXT User guide

Pentair

Pentair Fleck 2850 NXT User guide

Pentair FLECK PROFLOSXT DOWNFLOW User manual

Pentair

Pentair FLECK PROFLOSXT DOWNFLOW User manual

Pentair FLECK NXT User manual

Pentair

Pentair FLECK NXT User manual

Pentair AUTOTROL 368 User manual

Pentair

Pentair AUTOTROL 368 User manual

Pentair 2510 User manual

Pentair

Pentair 2510 User manual

Pentair FLECK 5800 User manual

Pentair

Pentair FLECK 5800 User manual

Pentair FLECK 3150 NXT User guide

Pentair

Pentair FLECK 3150 NXT User guide

Pentair F783E User manual

Pentair

Pentair F783E User manual

Popular Control Unit manuals by other brands

Festo Compact Performance CP-FB6-E Brief description

Festo

Festo Compact Performance CP-FB6-E Brief description

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

Elo TouchSystems

Elo TouchSystems DMS-SA19P-EXTME Quick installation guide

JS Automation MPC3034A user manual

JS Automation

JS Automation MPC3034A user manual

JAUDT SW GII 6406 Series Translation of the original operating instructions

JAUDT

JAUDT SW GII 6406 Series Translation of the original operating instructions

Spektrum Air Module System manual

Spektrum

Spektrum Air Module System manual

BOC Edwards Q Series instruction manual

BOC Edwards

BOC Edwards Q Series instruction manual

KHADAS BT Magic quick start

KHADAS

KHADAS BT Magic quick start

Etherma eNEXHO-IL Assembly and operating instructions

Etherma

Etherma eNEXHO-IL Assembly and operating instructions

PMFoundations Attenuverter Assembly guide

PMFoundations

PMFoundations Attenuverter Assembly guide

GEA VARIVENT Operating	 instruction

GEA

GEA VARIVENT Operating instruction

Walther Systemtechnik VMS-05 Assembly instructions

Walther Systemtechnik

Walther Systemtechnik VMS-05 Assembly instructions

Altronix LINQ8PD Installation and programming manual

Altronix

Altronix LINQ8PD Installation and programming manual

Eaton Powerware Series user guide

Eaton

Eaton Powerware Series user guide

WAGO 750-407/040-000 manual

WAGO

WAGO 750-407/040-000 manual

Sony CCU-590 Operation manual

Sony

Sony CCU-590 Operation manual

Graco 25D614 instructions

Graco

Graco 25D614 instructions

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Task Force Tips

Task Force Tips YE-RF-900 Instructions for installation, safe operation and maintenance

Shini SPV-U Series manual

Shini

Shini SPV-U Series manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

COMPONENTS
A) Pentair® Fleck 125 In-And-Out Valve
B) Bypass
C) Connector
B
A
B
1
3
4
4
3
2
1
2
TITLE
SIZE
SCALE
SHEET 1 OF 1
DWG NO.
REV
Pentair Residential
Filtration, LLC
CHECKED
APPROVED
APPROVALS
DATE
THIRD ANGLE
PROJECTION
DRAWN
B
1:2
REVISIONS
DATE
APP'D
DESCRIPTION
REV.
PCO
ZONE
A
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
UNLESS OTHERWISE SPECIFIED:
ALL FINISHED MACHINED SURFACES 125 OR BETTER.
TOLERANCES:
ANGLES :
1
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
BR42887
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS
B
A
B
1
3
4
4
3
2
1
2
TITLE
SIZE
SCALE
SHEET 1 OF 1
DWG NO.
REV
Pentair Residential
Filtration, LLC
CHECKED
APPROVED
APPROVALS
DATE
THIRD ANGLE
PROJECTION
DRAWN
B
1:2
REVISIONS
DATE
APP'D
DESCRIPTION
REV.
PCO
ZONE
A
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
UNLESS OTHERWISE SPECIFIED:
ALL FINISHED MACHINED SURFACES 125 OR BETTER.
TOLERANCES:
ANGLES :
1
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
BR42887
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS
B
A
B
1
3
4
4
3
2
1
2
TITLE
SIZE
SCALE
SHEET 1 OF 1
DWG NO.
REV
Pentair Residential
Filtration, LLC
CHECKED
APPROVED
APPROVALS
DATE
THIRD ANGLE
PROJECTION
DRAWN
B
1:2
REVISIONS
DATE
APP'D
DESCRIPTION
REV.
PCO
ZONE
A
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
UNLESS OTHERWISE SPECIFIED:
ALL FINISHED MACHINED SURFACES 125 OR BETTER.
TOLERANCES:
ANGLES :
1
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
BR42887
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS
A B C
PRODUCT SPECIFICATIONS AND OPERATION
Specication Description
Minimum Pressure 20 PSI
Maximum Pressure 125 PSI
Minimum Water Temperature 34°F (1°C)
Maximum Water Temperature 110°F (43°C)
Minimum Ambient Temperature 34°F (1°C)
Maximum Ambient Temperature 125°F (52°C)
Flow Rate 62134-01 62134-02
Downow Upow Downow Upow
Continuous
(15 psid drop)
54.9 GPM
[12.5 m3/hr]
47.4 GPM
[10.8 m3/hr]
62.3 GPM
[14.2 m3/hr]
62.6 GPM
[14.2 m3/hr]
Peak
(25 psid drop)
70.9 GPM
[16.1 m3/hr]
61.2 GPM
[13.9 m3/hr]
80.4 GPM
[18.3 m3/hr]
80.7 GPM
[18.3 m3/hr]
Cv
(Flow at 1 psi drop) 14.2 12.2 16.1 16.2
FLECK® 125 IN-AND-OUT VALVE
Installation Instructions
B
A
B
1
3
4
4
3
2
1
2
TITLE
SIZE
SCALE
SHEET 1 OF 1
DWG NO.
REV
Pentair Residential
Filtration, LLC
CHECKED
APPROVED
APPROVALS
DATE
THIRD ANGLE
PROJECTION
DRAWN
B
1:24
REVISIONS
DATE
APP'D
DESCRIPTION
REV.
PCO
ZONE
A
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
UNLESS OTHERWISE SPECIFIED:
ALL FINISHED MACHINED SURFACES 125 OR BETTER.
TOLERANCES:
ANGLES :
1
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
BR42887
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS
TOP VIEW
4006337 MY22
13845 Bishops Dr. | Suite 200 | Brookeld, WI 53005 | United States
P: 262.238.4400 | Customer Service: 800.279.9404 | tech-support@pentair.com | pentair.com
All indicated Pentair trademarks and logos are property of Pentair. Third party registered and unregistered
trademarks and logos are the property of their respective owners.
© 2022 Pentair. All rights reserved.
BYPASS OPERATION
1. Valve is in service when blue handles are turned parallel to inlet and out.
2. Valve is in bypass when both handles are turned clockwise and are perpendicular to inlet and outlet ports.
3.Todepressurizeadownowsystem:
a. Turn blue handle of supply side clockwise to be perpendicular to port.
 b.Openadownstreamwatertap/faucettorelievepressure.
c. Turn blue handle on treated water side clockwise so it is perpendicular to the port.
 d.RemovetheFleck125In-and-OutValvebyslowlyunthreadingthecouplingnuts.
4.Todepressurizeanupowsystem:
 a.Turnoffmainwatersupply.
 b.Openadownstreamwatertaptorelievepressure.
c. Turn both blue handles clockwise so they are perpendicular to the ports.
 d.Turnmainwatersupplybackon.
 e.RemovetheFleck125In-and-OutValvebyslowlyunthreadingthecouplingnuts.
As an option, a relief valve can be installed in either of the two ¼”-18 NPT ports and used to relieve pressure in the Fleck 125 In-and-Out
Valve afterthebypassvalvehasbeenputinthebypassposition.Followtheinstructionsbelow,items7and8,forpreparingthese
ports for use.
DIMENSIONAL DRAWINGS
29.6
1.17
47.8
1.88
69.7
2.74
25.4
1.00
36.8
1.45
55.8
2.20
68.6
2.70
120.7
4.75
133.2
5.24
1/4"-18 NPT FEMALE THREAD
TWO PLACES
TO OPEN, DRILL THROUGH
WITH 5/16" DRILL MAX.
36.8
1.45
47.9
1.89
25.4
1.00
69.7
2.74
68.6
2.70
138.4
5.45
36.8
1.45
55.8
2.20
145.8
5.74
1/4"-18 NPT FEMALE THREAD
TWO PLACES
TO OPEN, DRILL THROUGH
WITH 5/16" DRILL MAX.
62134-01 62134-02
B
A
B
1
3
4
4
3
2
1
2
TITLE
SIZE
SCALE
SHEET 1 OF 1
DWG NO.
REV
Pentair Residential
Filtration, LLC
CHECKED
APPROVED
APPROVALS
DATE
THIRD ANGLE
PROJECTION
DRAWN
LINE DRWG IN OUT HEAD ASSY
C
1:2
PS
5
5
C
D
D
C
REVISIONS
DATE
APP'D
DESCRIPTION
REV.
PCO
ZONE
B
A
DO NOT SCALE DRAWING. DIMS. ARE IN INCHES [mm]
INTERPRET DIMS AND TOLERANCES PER ASME Y14.5M -2009
UNLESS OTHERWISE SPECIFIED:
ALL FINISHED MACHINED SURFACES 125 OR BETTER.
TOLERANCES:
ANGLES :
1
1 PLACE .X:
.015 [0.38]
2 PLACE .XX:
.01 [0.3]
3 PLACE .XXX:
.005 [0.13]
BR42888
09/02/2020
THIS DOCUMENT IS SOLELY THE PROPERTY OF PENTAIR
RESIDENTIAL FILTRATION, LLC. REPRODUCTION, USE
DISCLOSURE, OR TRANSMISSION OF THIS DOCUMENT OR
DETAILS CONTAINED HEREIN, IN PART OR IN WHOLE, IS
PROHIBITED WITHOUT THE WRITTEN CONSENT OF PENTAIR
RESIDENTIAL FILTRATION, LLC ENGINEERING. THIS
DOCUMENT AND ANY COPIES SHALL BE RETURNED TO
PENTAIR RESIDENTIAL FILTRATION, LLC UPON REQUEST.
COMPONENTS / ASSEMBLIES TO BE COMPLIANT AND COMPATIBLE WITH EUROPEAN UNION DIRECTIVE 2011/65/EEC (RoHS2) & REGULATION (EC)1907/2006 (REACH) REQUIREMENTS
62134LNE
1.Theinformation,specicationsandillustrationsinthemanualarebasedonthelatestinformationavailableatthetimeofrelease.
Themanufacturerreservestherighttomakechangesatanytimewithoutnotice.
2.Thisproductshouldbeinstalledbyaplumbingprofessional.
3.Thisunitisdesignedtobeinstalledonpotablewatersystemsonly.
4.CheckallapplicableplumbingandbuildingcodesforinstallationcomplianceItisestablishedthatwhendaytimewaterpressureexceeds80psi(5.5bar),
themaximumpressureratingof125psi(8.6bar)canbeexceeded.Apressureregulatormustbeinstalledonthissystemorwarrantyisvoided.
5.Donotplacetheunitindirectsunlight.Blackunitswillabsorbradiantheat,increasinginternaltemperatures.
6.Donotstrikethevalveoranyofthecomponents.
7.Donotusepetroleum-basedlubricantssuchasVaseline,oils,orhydrocarbon-basedlubricantsonanyo-rings.Useonly100%siliconelubricants.
8.Whenusingtestports:
 -Toopenports,drillthroughwithcleandrillnolargerthan5/16”priortoinstallationofFleck125In-and-OutValveontank.Useacleandrillbitfreeofoil 
anddonotuseanydrillinglubricant.
 -Besuretocleanoutanychipsordebrispriortoinstallation.
 -Donotusemorethan2wrapsofTeontapewheninstallingacomponenttotheseports.Donotusepipedope.
 -Wheninstallingcomponentintothe¼-18NPTports,donotexceed25Lb-intorque.
IMPORTANT! PLEASE READ