Certificate & Operation Manual
2 TECHNICAL SPECIFICATIONS
Rated operating voltage1........................................................................................ 12 VDC
Operating voltage limits1 ................................................................................ 10.8–14 VDC
Consumption current .................................................................................................. 1.1 A
Power consumption ............................................................................................ max. 14 W
Controller connection interface .............................................................. RS-485, Wiegand2
Card reading distance at the rated operating voltage for different card types:
HID ProxCard II cards ............................................................................ max. 60 cm
EM-Marin IL-05ELR cards .................................................................... max. 100 cm
EM-Marin EM4100 cards ........................................................................ max. 70 cm
Length of cables (power and control) ............................................................................. 3 m
Mean lifetime ........................................................................................................... 8 years
Electric shock protection class ...................................................................... III (IEC 61140)
Ingress protection rating ........................................................................... IP54 (EN 60529)
Overall dimensions of reader (with a mounting arm) .............................. 408300×266 mm
Reader weight (with a mounting arm) ............................................................... max. 2.5 kg
3 DELIVERY SET
Attention!
The completeness of the delivery set shall be checked upon receipt.
Standard delivery set
Reader ............................................................................................................................... 1
Mounting arm ..................................................................................................................... 1
Jumper ............................................................................................................................... 3
Installation kit:
plastic dowel ............................................................................................................ 4
screw ....................................................................................................................... 4
Certificate and operation manual ....................................................................................... 1
Package ............................................................................................................................. 1
Additional equipment
BH-03 post ......................................................................................................................... 1
Power supply unit .............................................................................................................. 1
1 As a power supply it is recommended to use DC source with linear voltage stabilization and
output pulsation amplitude max. 50 mV.
2Wiegand, Wiegand 26, Wiegand 37, Wiegand 42.
4