Introduction. 3
Contents
Introduction ................................................................................................................... 5
Starting .......................................................................................................................... 7
Overview ................................................................................................................................8
Flexar SQ 300 MS Status LEDs .................................................................................................9
LED Functionality .............................................................................................................9
Starting the SQ 300 MS Detector ...........................................................................................10
Checking the Position of the ESI Probe.........................................................................11
Starting Chromera........................................................................................................ 13
Configuring Chromera ...........................................................................................................14
Creating a System Database ...........................................................................................14
Creating an LCMS Instrument..........................................................................................15
Setting the Operate Method ............................................................................................19
Auto Tune on the SQ 300 MS Detector ...................................................................................22
About the Samples .........................................................................................................22
PKI Tune Mix ..............................................................................................................22
Calibrants ...................................................................................................................22
Calibrant Delivery Modes .............................................................................................22
Preparing the Calibration Vials for Auto Tuning.................................................................23
Run an Auto Tune ..........................................................................................................24
Running Auto Tune from the Calibration Vials ..................................................................25
Running Auto Tune Using the Built-in Syringe Pump .........................................................33
Initial Process to Configure an Optimal Tune and Method on the SQ 300
MS Detector............................................................................................................... 35
Process Overview..................................................................................................................36
Setting up a Sample Infusion .................................................................................................37
Creating a Peak Detection Mini-Method ..................................................................................38
Ramping Parameters- Optimizing the Capillary Exit Voltage .....................................................46
Creating Methods and Sequences ................................................................................ 53
Creating an MS Method .........................................................................................................54
Creating a Chromera Method .................................................................................................61
Creating a Chromera Sequence..............................................................................................64
Starting Data Acquisition ............................................................................................. 67
Preparing for an Analysis .......................................................................................................68
Equilibrate the System...........................................................................................................69
Running a Sequence .............................................................................................................71
Analyze Results in Post Run......................................................................................... 75
Viewing the Results in Post Run .............................................................................................76
Importing Chromera Data and Methods..................................................................................80
Using the Data Selector .........................................................................................................83
Searching a Library to Identify Unknowns...............................................................................85
Viewing Spectra Results in the SQ 300 MS Driver Window .......................................................88
About the Total Ion Chromatogram (TIC) ...............................................................................90
Creating an Extracted Ion Chromatogram (EIC) ......................................................................91
Using the EIC Dialog.......................................................................................................91
Creating a Base Ion Chromatogram (BIC)...............................................................................93
Processing of Ion Chromatograms..........................................................................................95
Displaying Statistics ........................................................................................................96
About Right Mouse Click Menus.......................................................................................96
Baseline Calculation........................................................................................................96
Setting the Chromatogram Noise Calculation Preferences..................................................97
Chromatogram Threshold ...............................................................................................97