manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Philips
  6. •
  7. Controllers
  8. •
  9. Philips dynalite DDBC120-DALI User manual

Philips dynalite DDBC120-DALI User manual

DDBC120-DALI
DALI Multi Master Controller
Installation Manual
features
Supply –100-240V 50/60Hz Single Phase at 0.25A.
1 x DALI Output –Suitable for DALI HF ballasts, electronic low-
voltage transformers and LED fixtures. Philips Dynalite multi
master enabled for use with DPMI940-DALI and DUS804C-DALI
only.
1 x Feed Thru Switched Circuit –rated at 20A
Built-in DALI Bus Power Supply of 220mA @ 16VDC –No
external DALI power supply required.
Override and Status Indicator for Switched Channel
Dry Contact Interface –Can be programmed to perform many
different functions. The factory settings will cause this input to
transmit network identification information.
Many Control Options –Control of this device can be via a
combination of methods eg. Serial control port, relay contacts,
push button control panels, infrared receivers, timeclocks and
Philips Dynalite user interfaces on the DALI network.
Simple Installation –DIN Rail mount facilitates installation.
All connection terminals accessible without disassembly.
Warning –This is a class A product. In a domestic environment this product may
cause radio interference, in which case the user may be required to take adequate
measures.
Special Programming –This device is designed for professional installation only,
and will only operate in basic modes unless programmed via a computer. If
programming is required, contact your local agent for details. Once the data cable is
connected to the devices, the factory default settings will allow any control panel to
control all channels in all dimmers.
Check Connections –Re-tighten all connections after installation.
Power Sources –This device should only be operated from the type of supply
specified on the front cover. This device must be earthed.
Output Circuit –The load on the switched circuits should not exceed the specified
capacity of 20A, these circuits should be fed via a 20A circuit breaker.
Load Control Circuit –A 2 core DALI bus cable is required to be run to the loads,
this cable is in addition to the mains feed.
Load Type –This product is intended to control DALI devices and Switched
devices.
Mounting Location –Install in a dry, well-ventilated location. Controllers may emit
some mechanical noise. Take this into account when deciding the mounting location.
Data Cable
–Use screened, stranded RS485 data cable with three twisted pairs.
Segregate from mains cable by 300mm minimum. Connect devices in a ‘daisy
chain’. A data cable connected to an energized device is live. Do not cut or terminate
live data cables.
electrical diagram
To reduce the risk of fire or electric shock, do
not expose this device to rain or moisture. Do
not energise unless the front cover is in place.
The device must be earthed. Installation,
programming and maintenance must be carried
out by qualified personnel.
WARNING: Do not connect any DALI terminals
or wires to mains power. DALI wires are NOT
SELV and should never be considered touch
safe. Basic insulation or higher is required
between DALI wires and mains cabling.
Do not connect external DALI power supply to
the same DALI bus.
product specifications:
Supply:
100-240V 50/60Hz Single Phase at 0.25A
Control Output:
Mains Output:
1 x DALI Control Output, supporting one full DALI universe of 64 channels, including backward channel and multi
master communication to Philips Dynalite user interfaces.
1 x 20 Amp feed thru switched circuit for DALI ballast mains supply
Supply Terminals:
1 x Phase, 1 x Neutral, 1 x Earth, 1 x 4mm2max conductor size
Output Terminals:
1 x Ballast power circuit –Line in, Line out, Loop, Loop - 1 x 4mm2max conductor size
1 x DALI Ballast circuit - DA-, DA+ - 1 x 4mm2max conductor size
Control Inputs:
1 x RS485 DyNet serial port consisting of 1 x RJ12 socket & 1 x 5 way terminal block
1 x AUX dry contact input and ground
DALI BUS DC Supply:
Inbuilt, Rated 220mA @ 16VDC current unit max 250mA
DyNet DC Supply:
120mA (capacity for approximately 6 panels)
Preset Scenes:
170
Compliance:
CE, C-Tick
Operating Environment:
0° to 40°C ambient temperature
0% to 90% RH non-condensing
Construction:
Polycarbonate DIN rail mount
Dimensions:
H 93 mm x W 105mm x D 75mm
Weight:
0.45kg
DDBC120-DALI Instruction Manual Rev B.doc. Specifications subject to change without notice.
Philips Dynalite manufactured by WMGD Pty Ltd (ABN 33 097 246 921) Unit 6, 691 Gardeners Road Mascot NSW 2020 Australia Tel: +61 2 8338 9899 Fax: +61 2 8338 9333
Email [email protected]om Web: Philips.com/dynalite
installation steps
Isolate Mains supply, DALI and Dynet bus prior to wiring
1. Mount the device on a DIN rail inside an approved enclosure.
2. Connect single phase supply and earth to units supply terminals: This is required for the units operation.
3. Calculate total loading of the lighting to ensure the switched output is not overloaded. The maximum loading of this device shall not exceed 20A.
Ensure load in rush current does not exceed 500A, de-rating for electronic loads may apply. Then connect load cables between the “OUT”and
“LOOP”terminals.
4. Connect 20A active supply between “IN”& “LOOP”terminals. Supply must be protected by a 20A circuit breaker maximum.
5. Connect the DALI bus cables to “DA+”and “DA-“: Use a mains rated 2 core cable to connect the DALI bus to the DALI ports on all DALI
devices. The DALI bus cable should not be longer than 300 Metres, and should have a minimum cross section area based on cable length as
follows:
- Up to 100 Metres: 0.5mm2
- 100 to 150 Metres: 0.75mm2
- 150 to 300 Metres: 1.5mm2
The DALI bus is not SELV and must be treated as a mains cable. DALI is not polarity conscious. A maximum of 64 DALI devices plus a 10
Philips Dynalite user interfaces devices (DPMI940-DALI & DUS804C-DALI) can be connected together in a DALI network.
6. Connect Dynet data cables to the device as per diagrams below. Ensure segregate between data cables and mains powered cables.
7. If the Auxiliary input is to be used, connect a dry contact device in between the AUX and GND terminals. Keep cable runs between the AUX
terminals and the dry contacts under two metres. Function of the Auxiliary input will need to be programmed at the time of commissioning.
8. Re check all terminated cables and once safe power the unit on. Correct termination of the DALI ballasts can be verified by pushing the service
switch 4 times. This will invoke a light chase, where all the correctly terminated ballasts will cycle between 100% for 3 seconds, 40% for 3
seconds and 0% for 3 seconds. This chase will repeat for 5 minutes after which all ballasts will return to their original state when first powered.
Connecting Dynet Data Cable

Other Philips Controllers manuals

Philips DYNALITE DDRC1220FR-GL User manual

Philips

Philips DYNALITE DDRC1220FR-GL User manual

Philips LFH 2305 User manual

Philips

Philips LFH 2305 User manual

Philips dynalite DALI DDBC120-DALI User manual

Philips

Philips dynalite DALI DDBC120-DALI User manual

Philips Dynalite DMRC210 User manual

Philips

Philips Dynalite DMRC210 User manual

Philips Lightolier Controls Sunrise Whispurr User manual

Philips

Philips Lightolier Controls Sunrise Whispurr User manual

Philips Dynalite DDBC1200 User manual

Philips

Philips Dynalite DDBC1200 User manual

Philips Light System Manager User manual

Philips

Philips Light System Manager User manual

Philips 9890 000 0268 Series User manual

Philips

Philips 9890 000 0268 Series User manual

Philips Strand Lighting Sixer Instruction Manual

Philips

Philips Strand Lighting Sixer Instruction Manual

Philips iPlayer3 User manual

Philips

Philips iPlayer3 User manual

Philips ISP1362 User manual

Philips

Philips ISP1362 User manual

Philips Dynalite DMAL120F User manual

Philips

Philips Dynalite DMAL120F User manual

Philips Dynalite DMC2 User manual

Philips

Philips Dynalite DMC2 User manual

Philips Dynalite Revolution DR2PE User manual

Philips

Philips Dynalite Revolution DR2PE User manual

Philips Dynalite DLE1205 User manual

Philips

Philips Dynalite DLE1205 User manual

Philips LFC7310 User manual

Philips

Philips LFC7310 User manual

Philips Dynalite Revolution Series User manual

Philips

Philips Dynalite Revolution Series User manual

Philips SC1500 User manual

Philips

Philips SC1500 User manual

Philips DYNALITE DDRC420FR User manual

Philips

Philips DYNALITE DDRC420FR User manual

Philips CoralCare User manual

Philips

Philips CoralCare User manual

Philips NOA0025 User manual

Philips

Philips NOA0025 User manual

Philips Dynalite DLE1220GL User manual

Philips

Philips Dynalite DLE1220GL User manual

Philips Dynalite DRC810DT User manual

Philips

Philips Dynalite DRC810DT User manual

Philips Dynalite DMRC210DA-RJ12 User manual

Philips

Philips Dynalite DMRC210DA-RJ12 User manual

Popular Controllers manuals by other brands

Honeywell ML6275 Product data

Honeywell

Honeywell ML6275 Product data

ABB i-bus KNX JRA/S 6.230.3.1 product manual

ABB

ABB i-bus KNX JRA/S 6.230.3.1 product manual

Cisco SCE 2000 Installation and configuration guide

Cisco

Cisco SCE 2000 Installation and configuration guide

Nexen Paper Checker PC210 User manua

Nexen

Nexen Paper Checker PC210 User manua

MICRO-EPSILON C-Box/2A operating instructions

MICRO-EPSILON

MICRO-EPSILON C-Box/2A operating instructions

Burkert 8742 Additional instructions

Burkert

Burkert 8742 Additional instructions

Yamatake SDC35 user manual

Yamatake

Yamatake SDC35 user manual

Identiv Freedom Bridge installation guide

Identiv

Identiv Freedom Bridge installation guide

Jetter JCM-501-E01 user manual

Jetter

Jetter JCM-501-E01 user manual

ICP DAS USA LP-22 Series user manual

ICP DAS USA

ICP DAS USA LP-22 Series user manual

Curtis 1313 user manual

Curtis

Curtis 1313 user manual

Honeywell 023350.17 Mounting and Connection Instructions

Honeywell

Honeywell 023350.17 Mounting and Connection Instructions

Autani CORE/Manager user manual

Autani

Autani CORE/Manager user manual

Martin maxxyz modules series user manual

Martin

Martin maxxyz modules series user manual

usi SmartStep Full user manual

usi

usi SmartStep Full user manual

MADRIX Nebula user manual

MADRIX

MADRIX Nebula user manual

Binks 84-320 Service manual

Binks

Binks 84-320 Service manual

Zamel RZB-05 quick guide

Zamel

Zamel RZB-05 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.