Physio Logic QuickScan 016-670 User manual

Instructions
016-670
ON/OFF
°C
REV. 5 0217
P/N 861-016670
Consumer Info-Line
1-800-363-2381
TM
Physio Logic and QuickScan are trademarks
®
of AMG Medical Inc.
Model / Modèle : 016-670
Made and printed in Taiwan for:
A.M.G. Medical Inc.
8505 Dalton, Montréal, QC H4T 1V5
Canada • 1-800-363-2381
AMG Medical, Inc. (USA)
8396 State Route 9, West Chazy, NY 12992,
USA • 1-888-412-4992
Australian & NZ Distributor:
HMR Healthcare PL
Melbourne, VIC, 3189 Australia • 1800 363 238
www.amgphysiologic.com
Authorised Representative
in the European Community:
M. Devices Group / E. C. REP Ltd,
Healthcare Education Centre,
Portland Street, Southport,
PR8 1HU, UK.
Tel: +44 1704 544 944
Fax: +44 1704 544 050
Email: info@ecrep.com
EC REP
016-670 instructions rev5 0217
016-670 861-016670
6,75 " x 6,25 "
3 " x 5,5 " (folded) 6 " x 5,5 " (open)
This is for a 16 page (double-sided) saddle-stitched booklet.
Jean-François Perron
®

3
Contents
Introduction ................................................................... 3
Your thermometer .......................................................... 4
Important notes ......................................................... 4-5
Operating instructions................................................. 6-7
Fever alarm .................................................................... 7
To recall memory............................................................ 8
To switch between °C and °F ......................................... 8
Screen symbols............................................................... 9
To replace the battery..................................................... 9
Error messages ............................................................. 10
Troubleshooting ...................................................... 10-11
Care and cleaning......................................................... 11
About body temperature .............................................. 12
Average body temperature per age ............................... 12
Your normal temperature readings................................ 13
Technical specifications................................................. 14
Caution........................................................................ 14
Warranty...................................................................... 15
PLEASE READ THE ENTIRE INSTRUCTION MANUAL
BEFORE USING THIS THERMOMETER.
Proper measuring technique is crucial to achieving
accurate readings. Improper use will affect results.
2
Introduction
® TM
The Physio Logic Quick-Scan thermometer offers two
convenient ways to measure body temperature instantly and
accurately. What’s more, its colour-coded backlit screen alerts
you of a fever (orange) or lets you know that the reading is
normal (green) when in poor lighting conditions.
Please keep this instruction manual handy for future reference.
Fast:
• Advanced technology allows for instant digital readings
in less than 1 second.
Accurate:
• Clinically proven accuracy for readings you can trust.
Comfortable:
• Modern and versatile, compact design makes it easier to
measure temperature.
Hygienic:
• Easy to clean.
Convenient:
• No probe covers required.
• 2 temperature measuring options: Ear or Forehead.
• Memory stores last 10 readings.
User Friendly:
• One-button easy operation and large easy-to-read LCD.

5
Your thermometer
Optical lens Probe Scan button Display On/Off button
Function switch button Battery cover Screw
• This thermometer should not be used on children under
2 years of age. For older children infrared thermometers
should not be used to manage important health concerns.
• Use of this thermometer should not replace a visit
to your doctor.
• DO NOT use this thermometer to measure rectal, oral
or underarm temperature.
• This thermometer is calibrated, ready to use and does
not require probe covers.
• The thermometer body is NOT waterproof, only the
infrared probe is. Keep the thermometer away from
water and other liquids.
!
IMPORTANT NOTES
!
• This thermometer is a delicate electronic device.
Please handle with care. Do not expose it to direct sunlight.
Store at normal room temperature.
• Earwax and other obstructions will affect the accuracy of
the readings. Before using, ensure that the optical lens is
clean. If it is covered by earwax, wipe it with a cotton swab.
If desired, moisten the swab with alcohol. If alcohol
is used, wait 5 minutes after cleaning the lens before
taking a reading.
• Do not use the thermometer if the ear canal is wet
or if the person is suffering from an ear infection.
• Do not apply force when inserting the probe into ear canal.
• Do not use the thermometer if the ambient temperature
is below 10°C (50°F) or above 40°C (104°F) or if the
ambient humidity is higher than 95%RH.
• This thermometer is intended for household use only.
Use of this thermometer is not intended as a substitute
for a medical consultation.
4

76
Operating Instructions
Wait at least 30 minutes after eating, exercising
or bathing before taking a temperature reading.
1- Make sure that the optical lens is clean. (see p.4.)
2- Press the On/Off button to turn the power on. The display
will show all screen icons and will emit a beep. When the
symbol « » appears, the thermometer is ready.
3- To change the reading mode, press the function switch
button and hold it for 3 seconds. The « » symbol
indicates that the thermometer is now in forehead mode.
To switch back to ear mode, press the function switch
button again and hold it for 3 seconds (the « »
will disappear).
To use in forehead mode
1- Ensure that forehead mode
is active (« »).
2- Place the probe at temple level leaving
1 cm between the probe and the skin.
3- Press the scan button. A beep will indicate that the
measurement is complete and that the result will appear
on the display.
Since forehead temperature is lower than ear temperature
and it is easily influenced by ambient temperature, we
recommend to also measure the ear temperature if the
forehead reading is higher than 37°C.
!
!
To use in ear mode
1- Ensure that ear mode is active (“ ”).
2- Gently pull on the top of the ear to
straighten the ear canal. This will give
the thermometer a clear path to the eardrum.
3- Press the scan button. Keep the thermometer still until a
beep is heard.
4- After the beep, remove the thermometer carefully from the
ear canal. The temperature value will appear on the display.
Fever alarm
• When the temperature detected is above
38°C (100.4°F), the backlit screen turns
orange to indicate a possible fever. When
the reading is below 38°C (100.4°F), the
screen will remain green.
36.8
oC
Correct
34.6
oC
Incorrect
Eardrum
No fever
Fever

98
To recall memory
1. Press the On/Off button to turn the unit on, then press it a
second time.
2. The display will show the number 1 and then the value
of the last reading.
3. Press the On/Off button again. The display will show the
number 2 and then the value of the previous reading.
4. Repeat the process described above to view your
last 10 readings.
Note: each time that a new reading is taken, the oldest value
in memory is deleted and the new one is kept in memory.
To switch between °C and °F
1. Press the On/Off button to turn the unit on.
2. Press the On/Off button again and hold. While holding,
press the scan button once. The scale icon will switch from
°C to °F. Press the scan button again to return to the
previous scale. After selecting the desired scale, release
the On/Off button.
Low battery. The battery should be replaced.
LCD Description
Screen symbols
°C
°F
°C
°C
°C
°C
36.8
The unit is reporting the last temperature
detected and it is also ready for the
next reading.
The thermometer is taking readings.
Ready for forehead reading. The icons
“ ” indicate that the unit is in
forehead thermometer mode.
All icons are displayed. The unit has been
turned on.
Ready for ear readings. The icon “ ”
indicates that the unit is in ear
thermometer mode.
To replace the battery
When the low battery ( ) symbol appears, it is time
to replace the old battery with a new one.
1- Use a new lithium battery, type CR2032 or equivalent.
2- Take out the screw and remove the battery cover
3- Remove the old battery.
4- Place the new battery, making sure the + side is up.
5- Replace the battery cover and secure with the screw.
CR2032
Lithium
+

1110
Troubleshooting
1. If temperature readings are consistently low:
• The waterproof lens may be dirty.
Solution:
- Thoroughly clean the lens with a soft,
alchool-moistened cotton cloth.
• The probe may not be positionned proprely in the ear
canal (if used in ear mode).
Solution:
- Verify that the ear mode icon is visible.
°C
HI
°C
LO
°C
AH
°C
AL
LCD Comments
Error messages
°C
The temperature is higher than 50°C.
The temperature is lower than 0°C.
The ambient temperature is higher than 40°C.
The ambient temperature is lower than 10°C.
The battery running low.
Please replace the battery.
Check if the unit is turned on or if the
battery has been proprely installed.
- The tip of the probe must be fully seated against
the opening of ear canal. Failure to proprely position
the probe may lead to a low temperature reading.
2. If the thermometer displays an out of range error message
(HI, LO, AH or LH).
Solutions:
• Verify that you are using the correct reading
mode (ear or forehead).
• This may occur if you press the scan button before
placing the thermometer in the ear, while the
ambient temperature is not within the measuring range
(ear mode) (see p.14). Ensure that you are following the
instructions on p. 7.
• If operating in forehead mode, ensure that the
probe is not too far or too close from the skin
(1 cm is recommended).
Care and cleaning
Clean the uniquely-designed waterproof probe with a soft,
alcohol-moistened cloth after each use.
Clean the body of the ear thermometer with a soft, dry cloth.
DO NOT RINSE THE THERMOMETER BODY USING LIQUID.
Never use an abrasive cleanser or submerge the body
of the ear thermometer in water or other liquids.

1312
About body temperature
Several factors can affect normal body temperature. It
fluctuates throughout the day, being generally lower in the
morning and higher during the afternoon. Also as we age, our
normal body temperature tends to decrease slightly (see table
below for reference). Different parts of human body also have
different temperatures: generally, ear temperature is close to
oral temperature but higher than underarm temperature.
Average body temperature per age
Normal body temperature is different from person to
person. Knowing this temperature can be important for
® TM
future situations. Use your Physio Logic Quick-Scan
Thermometer to take a normal temperature reading
of you and each member of your family and write it
down in the chart for future reference.
Age 0-2 3-10 11-65 +65
°C 36.4 - 38.0 36.1 - 37.8 35.9 - 37.6 35.8 - 37.5
°F 97.5 - 100.4 97.0 - 100.4 96.6 - 99.7 96.4 - 99.5
Family member Reading Date
Your normal temperature readings

14
Warranty
® TM
Thank you for purchasing the Physio Logic Quick-Scan
thermometer. This product is warrented to be free from
defects in material and workmanship for a period of one
year of normal use from the date of purchase. This warranty
does not cover damages resulting from abusive or improper
use and applies to covered by this warranty. All claims must
be accompanied by the original bill of sale.
Physio Logic Quick-Scan
Thermometer (016-670)
Thermopile
Between 0°C and 50°C
(32°F and 122°F)
Between 10°C and 40°C
(50°F and 104°F)
0-95% RH
Memorizes last 10 readings
CR2032 Lithium cell (x1)
5,000 measurements or 2 years.
1 minute after last use
30g (including battery)
Complies with CE
and ASTM requirements
Class IIa
Caution
Do not expose the thermometer to extreme temperature,
very high humidity, or direct sunlight. Avoid extreme shock.
Do not drop the thermometer.
Do not touch the probe tip with fingers. Do not disassemble
the thermometer.
Model:
Sensor type:
Display
temperature range:
Operating ambient
temperature range:
Operating ambient
humidity range:
Memory:
Battery type:
Battery life:
Automatic switch off:
Weight:
Standard:
CE Medical device:
Technical specifications
15
Table of contents
Other Physio Logic Thermometer manuals

Physio Logic
Physio Logic Insta-Therm User manual

Physio Logic
Physio Logic ProScan 016-660 User manual

Physio Logic
Physio Logic Accuflex 5 User manual

Physio Logic
Physio Logic Insta-Therm User manual

Physio Logic
Physio Logic Accuflexpro User manual

Physio Logic
Physio Logic Accuflex 5 VU User manual

Physio Logic
Physio Logic DiGiPro User manual

Physio Logic
Physio Logic Accuflex Pro User manual

Physio Logic
Physio Logic DiGiPro User manual

Physio Logic
Physio Logic Accuflex PRO Plus User manual