Pilz PNOZ V User manual

-~
ARTISAN
®
~I
TECHNOLOGY
GROUP
Your definitive source
for
quality
pre-owned
equipment.
Artisan Technology
Group
Full-service,
independent
repair
center
with
experienced
engineers
and
technicians
on staff.
We
buy
your
excess,
underutilized,
and
idle
equipment
along
with
credit
for
buybacks
and
trade-ins
.
Custom
engineering
so
your
equipment
works
exactly as
you
specify.
•
Critical
and
expedited
services
•
Leasing
/
Rentals/
Demos
• In
stock/
Ready-to-ship
•
!TAR-certified
secure
asset
solutions
Expert
team
ITrust
guarantee
I
100%
satisfaction
All
tr
ademarks,
br
a
nd
names, a
nd
br
a
nd
s a
pp
earing here
in
are
th
e property of
th
e
ir
r
es
pecti
ve
ow
ner
s.
Visit our website - Click HERE

PNOZ V
Operating Manual-21115-EN-07
}Safety relays

Preface
This document is the original document.
Where unavoidable, for reasons of readability, the masculine form has been selected when
formulating this document. We do assure you that all persons are regarded without discrim-
ination and on an equal basis.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for the user's internal purposes. Suggestions and comments for improving this documenta-
tion will be gratefully received.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries.
SD means Secure Digital

Contents
Operating Manual PNOZ V
21115-EN-07 | 3
Introduction ............................................................................................................................4
Validity of documentation.......................................................................................................... 4
Using the documentation .......................................................................................................... 4
Definition of symbols................................................................................................................. 4
Safety ...................................................................................................................................... 5
Intended use ............................................................................................................................. 5
Safety regulations ..................................................................................................................... 5
Safety assessment ................................................................................................................... 5
Use of qualified personnel ........................................................................................................ 6
Warranty and liability ................................................................................................................ 6
Disposal .................................................................................................................................... 6
For your safety.......................................................................................................................... 6
Unit features ...........................................................................................................................7
Safety features ....................................................................................................................... 7
Block diagram/terminal configuration ................................................................................. 7
Function Description ............................................................................................................. 8
Operating modes ...................................................................................................................... 8
Timing diagram ......................................................................................................................... 9
Installation ..............................................................................................................................9
Wiring ...................................................................................................................................... 10
Preparing for operation ......................................................................................................... 11
Operation ................................................................................................................................12
Status indicators ....................................................................................................................... 13
Faults – Interference .............................................................................................................. 13
Dimensions in mm .................................................................................................................13
Technical details ....................................................................................................................14
Safety characteristic data ......................................................................................................... 20
Supplementary data ..............................................................................................................21
Service life graph ...................................................................................................................... 21
Order reference ......................................................................................................................22
EC declaration of conformity ................................................................................................ 22
UKCA-Declaration of Conformity ......................................................................................... 22

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 4
Introduction
Validity of documentation
This documentation is valid for the product PNOZ V. It is valid until new documentation is
published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
Using the documentation
This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.
Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
NOTICE
This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 5
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The safety relay PNOZ V provides a safety-related interruption of a safety circuit.
The safety relay meets the requirements of EN 60947-5-1 and EN 60204-1 and may be
used in applications with:
}E-STOP pushbuttons
}Safety gates
Improper use
The following is deemed improper use in particular
}Any component, technical or electrical modification to the product,
}Use of the product outside the areas described in this operating manual,
}Use of the product outside the technical details (see Technical details [ 14]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a device, a safety assessment in accordance with the Machinery Directive is
required.
The product as an individual component fulfils the functional safety requirements in accord-
ance with EN ISO 13849 and EN 62061. However, this does not guarantee the functional
safety of the overall plant/machine. To achieve the relevant safety level of the overall plant/
machine’s required safety functions, each safety function needs to be considered separ-
ately.

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 6
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by persons who are competent to do so.
A competent person is a qualified and knowledgeable person who, because of their train-
ing, experience and current professional activity, has the specialist knowledge required. To
be able to inspect, assess and operate devices, systems and machines, the person has to
be informed of the state of the art and the applicable national, European and international
laws, directives and standards.
It is the company’s responsibility only to employ personnel who
}Are familiar with the basic regulations concerning health and safety / accident prevention,
}Have read and understood the information provided in the section entitled Safety
}Have a good knowledge of the generic and specialist standards applicable to the specific
application.
Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended,
}Damage can be attributed to not having followed the guidelines in the manual,
}Operating personnel are not suitably qualified,
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Disposal
}In safety-related applications, please comply with the mission time TM in the safety-related
characteristic data.
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
For your safety
The unit meets all the necessary conditions for safe operation. However, please note the
following:
}Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120
VDC) are present on the unit, connected control elements and sensors must have a rated
insulation voltage of at least 250 V.

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 7
Unit features
}Positive-guided relay outputs:
– 3 safety contacts (N/O), instantaneous
– 1 safety contact (N/O), delay-on de-energisation
– 1 auxiliary contact (N/C), instantaneous
}Connection options for:
– E-STOP pushbutton
– Safety gate limit switch
– Start button
}Selectable delay time
}LED display for:
– Supply voltage
– Switch status of the safety contacts
}See order reference for unit types
Safety features
The safety relay meets the following safety requirements:
}The circuit is redundant with built-in self-monitoring.
}The safety function remains effective in the case of a component failure.
}The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.
Block diagram/terminal configuration
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 8
Function Description
The safety relay PNOZ V provides a safety-oriented interruption of a safety circuit. When
supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation when the
feedback loop Y1-Y2 and the start circuit S33-S34 are closed.
}Input circuit is closed (e.g. E-STOP pushbutton not operated):
– The LEDs "CH.1", "CH.1 [t]" and "CH.2", "CH.2 [t]" are lit.
– Safety contacts 13-14, 23-24, 33-34 and 57-58 are closed, auxiliary contact 41-42 is
opened. The unit is active.
}Input circuit is opened (e.g. E-STOP pushbutton operated):
– The LEDs "CH.1" and "CH.2" go out.
– Safety contacts 13-14, 23-24 and 33-34 are opened redundantly, auxiliary contact
41-42 is closed.
– Once the set delay time t2 has elapsed, safety contact 57-58 opens.
– The LEDs "CH.1 [t]" and "CH.2 [t]" go out.
The delay time for safety contact 57-58 can be set on the front of the unit using a screw-
driver.
Operating modes
}Single-channel operation: No redundancy in the input circuit, earth faults in the start and
input circuit are detected.
}Dual-channel operation without detection of shorts across contacts: Redundant input cir-
cuit, detects PNOZ V
– earth faults in the start and input circuit,
– short circuits in the input circuit.
}Automatic start: Unit is active once the input circuit has been closed within the simultan-
eity period.
}Manual start: Unit is active once the input circuit and the start circuit are closed.
}Increase in the number of available contacts by connecting contact expandsion modules
or external contactors/relays.

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 9
Timing diagram
Output safe delay
v
[1] [2]
v v v
Legend
}Power: Supply voltage
}Start: Start circuit
}Input: Input circuits
}Output safe: Safety contacts, instantaneous
}Output safe delay: Safety contacts, delayed
}[1]: Automatic start
}[2]: Manual start
}a: Input circuit closes before start circuit
}b: Start circuit closes before input circuit
}t1: Switch-on delay
}t2: Delay-on de-energisation
}t3: Recovery time
}tv: Delay time
NOTICE
At the latest the safety contacts open after the set delay time + 50 ms +
15% of the set value, even in the case of a component failure.
Installation
}The unit should be installed in a control cabinet with a protection type of at least IP54.
}Use the notch on the rear of the unit to attach it to a DIN rail (35 mm).
}When installed vertically: Secure the unit by using a fixing element (e.g. retaining bracket
or end angle).

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 10
Wiring
Please note:
}Information given in the "Technical details [ 14]" must be followed.
}Outputs 13-14, 23-24 and 33-34 are instantaneous safety contacts, output 57-58 is a
delay-on de-energisation safety contacts, output 41-42 is an auxiliary contact (e.g. for dis-
play).
}Auxiliary contact 41-42 shouldnot be used for safety circuits!
}Do not connect undesignated terminals.
}To prevent contact welding, a fuse should be connected before the output contacts (see
Technical details [ 14]).
}Calculation of the max. cable length lmax in the input circuit:
Rlmax
Rl / km
Imax =
Rlmax = max. overall cable resistance (see Technical details [ 14])
Rl/km = cable resistance/km
}Use copper wiring with a temperature stability of 60/75 °C.
}To prevent EMC interferences (particularly common-mode interferences) the measures
described in EN60204-1 must be executed. This includes the separate routing of cables
of the control circuits (input, start and feedback loop) from other cables for energy trans-
mission or the shielding of cables, for example.
}Adequate protection must be provided on all output contacts with capacitive and inductive
loads.
}Do not switch low currents using contacts that have been used previously with high cur-
rents.
}The power supply must comply with the regulations for extra low voltages with protective
electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410.

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 11
Preparing for operation
Supply voltage AC DC
A1
A2
L+
L-
Input circuit Single-channel Dual-channel
E-STOP
without detection of shorts across
contacts
S1
S11
S22
S12
S1
S11
S12
S22
Safety gate
without detection of shorts across
contacts
S1
S11
S22
S12
S1 S2
S11
S12
S22
NOTICE
With single-channel wiring the safety level of your machine/plant may be
lower than the safety level of the unit (see Safety characteristic data).
Start circuit E-STOP wiring
(single-channel, dual-channel)
Safety gate (single-channel)
Safety gate (dual-channel)
Automatic start
Manual start
S33
S34
S3
S33
S34
S3

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 12
NOTICE
In the event of an automatic start or manual start with bridged start
contact (fault):
The unit starts up automatically when the safeguard is reset, e.g. when the
E-STOP pushbutton is released. Use external circuit measures to prevent
an unexpected restart.
Feedback loop Without feedback loop monitor-
ing
With feedback loop monitoring
Link or contacts from external
contactors
K5 K6
K5
L1
N
K6
Y1
13 (23, 33, 57)
Y2
14 (24, 34, 58)
Legend
}S1: E-STOP pushbuttons
}S3: Start button
}: Switch operated
}: Gate open
}: Gate closed
Operation
When the relay outputs are switched on, the mechanical contact on the relay cannot be
tested automatically. Depending on the operational environment, measures to detect the
non-opening of switching elements may be required under some circumstances.
When the product is used in accordance with the European Machinery Directive, a check
must be carried out to ensure that the safety contacts on the relay outputs open correctly.
Open the safety contacts (switch off output) and start the device again, so that the internal
diagnostics can check that the safety contacts open correctly
}for SIL CL 3/PL e at least 1x per month
}for SIL CL 2/PL d at least 1x per year
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 13
Status indicators
LEDs indicate the status and errors during operation:
LED on
POWER
Supply voltage is present.
CH.1
Safety contacts of channel 1 are closed.
CH.2
Safety contacts of channel 2 are closed.
CH.1 [t]
Channel 3 safety contacts are closed.
CH.2 [t]
Channel 4 safety contacts are closed.
Faults – Interference
}Earth fault: The supply voltage fails and the safety contacts open. Once the cause of the
respective fault has been rectified and the supply voltage is switched off for approx.
1minute, the unit is ready for operation again.
}Contact malfunctions: If the contacts have welded, reactivation will not be possible after
the input circuit has opened.
}LED "POWER" does not light: Short circuit or no supply voltage.
}In the case of an error, the delay-on de-energisation contacts may open before the delay
time has elapsed.
Dimensions in mm

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 14
Technical details
General 774789 774790 774791
Certifications
CCC, CE, EAC, TÜV,
UKCA, cULus Listed
CCC, CE, EAC, TÜV,
UKCA, cULus Listed
CCC, CE, EAC, TÜV,
UKCA, cULus Listed
Electrical data 774789 774790 774791
Supply voltage
Voltage 24 V 24 V 24 V
Kind DC DC DC
Voltage tolerance -15 %/+10 % -15 %/+10 % -15 %/+10 %
Output of external
power supply (DC) 5 W 5 W 5 W
Residual ripple DC 160 % 160 % 160 %
Duty cycle 100 % 100 % 100 %
Max. inrush current im-
pulse
Current pulse, A1 10 A 10 A 10 A
Pulse duration, A1 0,5 ms 0,5 ms 0,5 ms
Inputs 774789 774790 774791
Number 222
Voltage at
Input circuit DC 24 V 24 V 24 V
Start circuit DC 24 V 24 V 24 V
Feedback loop DC 24 V 24 V 24 V
Current at
Input circuit DC 50 mA 50 mA 50 mA
Start circuit DC 40 mA 40 mA 40 mA
Feedback loop DC 40 mA 40 mA 40 mA
Max. overall cable resist-
ance Rlmax
Single-channel at UB
DC 100 Ohm 100 Ohm 100 Ohm
Dual-channel without
detection of shorts
across contacts at UB
DC 200 Ohm 200 Ohm 200 Ohm
Relay outputs 774789 774790 774791
Number of output con-
tacts
Safety contacts (N/O),
instantaneous 333
Safety contacts (N/O),
delayed 111
Auxiliary contacts (N/C) 111
Max. short circuit current
IK 1 kA 1 kA 1 kA

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 15
Relay outputs 774789 774790 774791
Utilisation category
In accordance with the
standard EN 60947-4-1 EN 60947-4-1 EN 60947-4-1
Utilisation category of
safety contacts
AC1 at 400 V 400 V 400 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 5 A 5 A 5 A
Max. power 2000 VA 2000 VA 2000 VA
AC1 at 240 V 240 V 240 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 2000 VA 2000 VA 2000 VA
DC1 at 24 V 24 V 24 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 200 W 200 W 200 W
Utilisation category of
safety contacts delayed
AC1 at 240 V 240 V 240 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 4 A 4 A 4 A
Max. power 1000 VA 1000 VA 1000 VA
DC1 at 24 V 24 V 24 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 4 A 4 A 4 A
Max. power 100 W 100 W 100 W
Utilisation category of
auxiliary contacts
AC1 at 240 V 240 V 240 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 2000 VA 2000 VA 2000 VA
DC1 at 24 V 24 V 24 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 200 W 200 W 200 W
Utilisation category
In accordance with the
standard EN 60947-5-1 EN 60947-5-1 EN 60947-5-1
Utilisation category of
safety contacts
AC15 at 230 V 230 V 230 V
Max. current 5 A 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V 24 V
Max. current 7 A 7 A 7 A

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 16
Relay outputs 774789 774790 774791
Utilisation category of
safety contacts delayed
AC15 at 230 V 230 V 230 V
Max. current 4 A 4 A 4 A
DC13 (6 cycles/min) at 24 V 24 V 24 V
Max. current 4 A 4 A 4 A
Utilisation category of
auxiliary contacts
AC15 at 230 V 230 V 230 V
Max. current 5 A 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V 24 V
Max. current 7 A 7 A 7 A
Utilisation category in ac-
cordance with UL
Voltage 240 V AC G. P. 240 V AC G. P. 240 V AC G. P.
With current 8 A 8 A 8 A
Voltage 24 V DC Resistive 24 V DC Resistive 24 V DC Resistive
With current 5 A 5 A 5 A
Pilot Duty C300, R300 C300, R300 C300, R300
External contact fuse pro-
tection, safety contacts
In accordance with the
standard EN 60947-5-1 EN 60947-5-1 EN 60947-5-1
Max. melting integral 240 A²s 240 A²s 240 A²s
Blow-out fuse, quick 10 A 10 A 10 A
Blow-out fuse, slow 6 A 6 A 6 A
Blow-out fuse, gG 10 A 10 A 10 A
Circuit breaker 24V
AC/DC, characteristic
B/C 6 A 6 A 6 A
External contact fuse pro-
tection, delayed safety
contacts
Max. melting integral 240 A²s 240 A²s 240 A²s
Blow-out fuse, quick 6 A 6 A 6 A
Blow-out fuse, slow 4 A 4 A 4 A
Blow-out fuse, gG 6 A 6 A 6 A
Circuit breaker 24 V
AC/DC, characteristic
B/C 4 A 4 A 4 A

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 17
Relay outputs 774789 774790 774791
External contact fuse pro-
tection, auxiliary contacts
Max. melting integral 240 A²s 240 A²s 240 A²s
Blow-out fuse, quick 10 A 10 A 10 A
Blow-out fuse, slow 6 A 6 A 6 A
Blow-out fuse, gG 10 A 10 A 10 A
Circuit breaker 24 V
AC/DC, characteristic
B/C 6 A 6 A 6 A
Contact material AgSnO2 + 0,2µ Au AgSnO2 + 0,2µ Au AgSnO2 + 0,2µ Au
Conventional thermal
current while loading
several contacts
774789 774790 774791
Ith per contact at UB DC;
AC1:240V,DC1:24V
Conv. therm. current
with 1 contact 8 A 8 A 8 A
Conv. therm. current
with 2 contacts 7,4 A 7,4 A 7,4 A
Conv. therm. current
with 3 contacts 6 A 6 A 6 A
Conv. therm. current
with 4 contacts 4 A 4 A 4 A
Times 774789 774790 774791
Switch-on delay
With automatic start
typ. 140 ms 140 ms 140 ms
With automatic start
max. 200 ms 200 ms 200 ms
With automatic start
after power on typ. 150 ms 150 ms 150 ms
With automatic start
after power on max. 220 ms 220 ms 220 ms
With manual start typ. 160 ms 160 ms 160 ms
With manual start max. 200 ms 200 ms 200 ms
Delay-on de-energisation
With E-STOP typ. 15 ms 15 ms 15 ms
With E-STOP max. 30 ms 30 ms 30 ms
With power failure typ. 50 ms 50 ms 50 ms
With power failure max. 100 ms 100 ms 100 ms
Recovery time at max.
switching frequency 1/s
After E-STOP 50 ms +tv 50 ms +tv 50 ms +tv
After power failure 150 ms 150 ms 150 ms
Delay time tv 0,1 s, 0,2 s, 0,3 s, 0,4 s,
0,5 s, 0,6 s, 0,7 s, 0,8 s, 1
s, 1,5 s, 2 s, 3 s
0,05 s, 0,5 s, 1 s, 2 s, 4 s,
6 s, 8 s, 10 s, 15 s, 20 s,
25 s, 30 s
0,15 s, 5 s, 10 s, 20 s, 40
s, 60 s, 80 s, 100 s, 150
s, 200 s, 250 s, 300 s
Time accuracy -15 %/+15 % +50 ms -15 %/+15 % +50 ms -15 %/+15 % +50 ms

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 18
Times 774789 774790 774791
Repetition accuracy 2 % 2 % 2 %
Supply interruption before
de-energisation 20 ms 20 ms 20 ms
Simultaneity, channel 1
and 2 max. 75 ms 75 ms 75 ms
Environmental data 774789 774790 774791
Climatic suitability EN 60068-2-78 EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -10 - 55 °C -10 - 55 °C -10 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C -40 - 85 °C
Climatic suitability
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation during op-
eration Not permitted Not permitted Not permitted
EMC EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
Vibration
In accordance with the
standard EN 60068-2-6 EN 60068-2-6 EN 60068-2-6
Frequency 10 - 55 Hz 10 - 55 Hz 10 - 55 Hz
Amplitude 0,35 mm 0,35 mm 0,35 mm
Airgap creepage
In accordance with the
standard EN 60947-1 EN 60947-1 EN 60947-1
Overvoltage category III / II III / II III / II
Pollution degree 222
Rated insulation voltage 400 V 400 V 400 V
Rated impulse withstand
voltage 4 kV 4 kV 4 kV
Protection type
Housing IP40 IP40 IP40
Terminals IP20 IP20 IP20
Mounting area (e.g.
control cabinet) IP54 IP54 IP54
Mechanical data 774789 774790 774791
Mounting position Any Any Any
Mechanical life 10,000,000 cycles 10,000,000 cycles 10,000,000 cycles
Material
Bottom PPO UL 94 V1 PPO UL 94 V1 PPO UL 94 V1
Front ABS UL 94 V0 ABS UL 94 V0 ABS UL 94 V0
Top PPO UL 94 V1 PPO UL 94 V1 PPO UL 94 V1
Connection type Screw terminal Screw terminal Screw terminal
Mounting type Fixed Fixed Fixed

PNOZ V
Operating Manual PNOZ V
21115-EN-07 | 19
Mechanical data 774789 774790 774791
Conductor cross section
with screw terminals
1 core flexible 0,2 - 4 mm², 24 - 10 AWG 0,2 - 4 mm², 24 - 10 AWG 0,2 - 4 mm², 24 - 10 AWG
2 core with the same
cross section, flexible
with crimp connectors,
no plastic sleeve
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
2 core with the same
cross section, flexible
without crimp connect-
ors or with TWIN crimp
connectors
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
0,2 - 2,5 mm², 24 - 14
AWG
Torque setting with screw
terminals 0,6 Nm 0,6 Nm 0,6 Nm
Stripping length with
screw terminals 8 mm 8 mm 8 mm
Dimensions
Height 87 mm 87 mm 87 mm
Width 90 mm 90 mm 90 mm
Depth 121 mm 121 mm 121 mm
Weight 475 g 475 g 475 g
Where standards are undated, the 2020-07 latest editions shall apply.
Other manuals for PNOZ V
1
Table of contents
Other Pilz Relay manuals