Operating Manual PNOZ XV3P
20122-EN-05 3
Introduction 5
Validity of documentation 5
Using the documentation 5
Definition of symbols 5
Safety 6
Intended use 6
Safety regulations 6
Safety assessment 6
Use of qualified personnel 7
Warranty and liability 7
Disposal 7
For your safety 7
Unit features 8
Safety features 8
Block diagram/terminal configuration 9
Function Description 9
Operating modes 10
Timing diagram 11
Installation 11
Wiring 12
Preparing for operation 13
Operation 15
Status indicators 15
Faults – Interference 16
Dimensions in mm 16
Technical details 17
Safety characteristic data 32
Supplementary data 32
Service life graph 33

Contents
Operating Manual PNOZ XV3P
20122-EN-05 4
Remove plug-in terminals 34
Order reference 35
EC declaration of conformity 35

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 5
Introduction
Validity of documentation
This documentation is valid for the product PNOZ XV3P. It is valid until new documentation
is published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
Using the documentation
This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.
Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
NOTICE
This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 6
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The safety relay PNOZ XV3P provides a safety-related interruption of a safety circuit.
The safety relay meets the requirements of EN60947-5-1, EN60204-1 and VDE0113‑1
and may be used in applications with
}E-STOP pushbuttons
}Safety gates
}Light grids and safety switches with detection of shorts across contacts
The following is deemed improper use in particular:
}Any component, technical or electrical modification to the product
}Use of the product outside the areas described in this manual
}Use of the product outside the technical details (see Technical details [ 17]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a unit it is necessary to perform a safety assessment in accordance with the
Machinery Directive.
Functional safety is guaranteed for the product as a single component. However, this does
not guarantee the functional safety of the overall plant/machine. In order to achieve the re-
quired safety level for the overall plant/machine, define the safety requirements for the
plant/machine and then define how these must be implemented from a technical and organ-
isational standpoint.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 7
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by competent persons.
A competent person is someone who, because of their training, experience and current pro-
fessional activity, has the specialist knowledge required to test, assess and operate the
work equipment, devices, systems, plant and machinery in accordance with the general
standards and guidelines for safety technology.
It is the company’s responsibility only to employ personnel who:
}Are familiar with the basic regulations concerning health and safety / accident preven-
tion
}Have read and understood the information provided in this description under "Safety"
}And have a good knowledge of the generic and specialist standards applicable to the
specific application.
Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended
}Damage can be attributed to not having followed the guidelines in the manual
}Operating personnel are not suitably qualified
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Disposal
}In safety-related applications, please comply with the mission time TM in the safety-re-
lated characteristic data.
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
For your safety
The unit meets all the necessary conditions for safe operation. However, please note the
following:
}Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120
VDC) are present on the unit, connected control elements and sensors must have a
rated insulation voltage of at least 250 V.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 8
Unit features
}Positive-guided relay outputs:
– 3 safety contacts (N/O), instantaneous
– 2 safety contacts (N/O), delay-on de-energisation
}Connection options for:
– E-STOP pushbuttons
– Safety gate limit switches
– Start buttons
– Light grids and safety switches with detection of shorts across contacts
}Delay time fixed or selectable
}Possible to cancel delay time
}LED display for:
– Supply voltage
– Switch state of the safety contacts
– Start circuit
}Plug-in connection terminals (either spring-loaded terminal or screw terminal)
}See order reference for unit types
Safety features
The safety relay meets the following safety requirements:
}The circuit is redundant with built-in self-monitoring.
}The safety function remains effective in the case of a component failure.
}The correct opening and closing of the safety function relays is tested automatically in
each on-off cycle.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 9
Block diagram/terminal configuration
*
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)
Function Description
The safety relay PNOZ XV3P provides a safety-oriented interruption of a safety circuit.
When supply voltage is supplied the "POWER" LED is lit. The unit is ready for operation
when the reset circuit Y39-Y40 and the start circuit S13-S14 are closed.
}Input circuit is closed (e.g. E-STOP pushbutton not operated):
– The "START" LED is lit.
– The LEDs "CH.1", "CH.1 [t]", "CH.2" and "CH.2 [t]" are lit.
– Safety contacts 13-14, 23-24, 33-34, 47-48 and 57-58 are closed. The unit is active.
– The "START" LED goes out.
}Input circuit is opened (e.g. E-STOP pushbutton operated):
– The LEDs "CH.1" and "CH.2" go out.
– Safety contacts 13-14, 23-24 and 33-34 are opened redundantly.
– Safety contacts 47-48 and 57-58 open after the delay time has elapsed.
– The LEDs "CH.1 [t]" and "CH.2 [t]" go out.
Before the unit can be restarted, the delay time must have elapsed and the unit must again
be ready for operation.
Set delay time:
On units with selectable delay time, the delay time of the safety contacts 47-48 and 57-58
can be set on the front of the unit using a screwdriver.
Reset function:
The delay time cycle can be ended prematurely by opening the reset circuit Y39-Y40. For
this purpose, one N/C contact is connected between Y39-Y40 instead of a link.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 10
Operating modes
}Single-channel operation: No redundancy in the input circuit, earth faults in the start
and input circuit are detected.
}Dual-channel operation with detection of shorts across contacts: Redundant input cir-
cuit, detects PNOZ XV3P
– earth faults in the start and input circuit,
– short circuits in the input circuit,
– Shorts across contacts in the input circuit.
}Dual-channel operation without detection of shorts across contacts: Redundant input
circuit, detects PNOZ XV3P
– earth faults in the start and input circuit,
– short circuits in the input circuit.
}Automatic start: Unit is active once the input circuit has been closed.
}Monitored start: Unit is active once the input circuit is closed and once the start circuit is
closed after the waiting period has elapsed (see Technical details [ 17]).
}Increase in the number of available contacts by connecting contact expander modules
or external contactors/relays.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 11
Timing diagram
vv
vvvv
vv
[1] [2]
Output safe delay
Output safe
Legend
}Power: Supply voltage
}Start: Start circuit
}Reset tv: Reset circuit
}Input: Input circuit
}Output safe: Safety contacts, instantaneous
}Output safe delay: Safety contacts, delayed
}[1]: Automatic start
}[2]: Monitored start
}t1: Switch-on delay
}t2: Delay-on de-energisation
}t3: Waiting period with a monitored start
}t4: Recovery time
}tv: Delay time
NOTICE
At the latest, the delay-on de-energisation safety contacts open after the set
delay time + 50 ms + 15% of the set value, even in the case of a component
failure.
Installation
}The unit should be installed in a control cabinet with a protection type of at least IP54.
}Use the notch on the rear of the unit to attach it to a DIN rail.
}Ensure the unit is mounted securely on a vertical DIN rail (35 mm) by using a fixing ele-
ment (e.g. retaining bracket or an end angle).

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 12
Wiring
Please note:
}Information given in the "Technical details [ 17]" must be followed.
}Delivery status of units with screw terminals: Link between S11-S12 (dual-channel input
circuit) and link between Y39-Y40 (reset circuit)
}Outputs 13-14, 23-24, 33-34 are instantaneous safety contacts, outputs 47-48, 57-58
are delay-on de-energisation safety contacts.
}Do not connect undesignated terminals.
}To prevent contact welding, a fuse should be connected before the output contacts (see
Technical details [ 17]).
}Calculation of the max. cable runs lmax in the input circuit:
Rlmax
Rl / km
Imax =
Rlmax = max. overall cable resistance (see Technical details [ 17])
Rl/km = cable resistance/km
}Use copper wire that can withstand 60/75°C.
}Sufficient fuse protection must be provided on all output contacts with capacitive and in-
ductive loads.
}Do not switch low currents using contacts that have been used previously with high cur-
rents.
}When connecting magnetically operated, reed proximity switches, ensure that the max.
peak inrush current (on the input circuit) does not overload the proximity switch.
}The power supply must comply with the regulations for extra low voltages with protect-
ive electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410.
}Ensure the wiring and EMC requirements of IEC 60204-1 are met.
Important for detection of shorts across contacts:
As this function for detecting shorts across contacts is not failsafe, it is tested by Pilz during
the final control check. If there is a danger of exceeding the cable length, we recommend
the following test once the unit is installed:
1. Unit ready for operation (output contacts closed)
2. Short circuit the test terminals S22, S32 for detecting shorts across the inputs.
3. The unit‘s fuse must be triggered and the output contacts must open. Cable lengths in
the scale of the maximum length can delay the fuse triggering for up to 2 minutes.
4. Reset the fuse: Remove the short circuit and switch off the supply voltage for approx. 1
minute.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 13
Preparing for operation
Supply voltage AC DC
A1
A2
L+
L-
Input circuit Single-channel Dual-channel
E-STOP
without detection of shorts
across contacts
S1
S22
S21
S12
S32
S11
S31
S1
S11
S12
S32
S22
S21
E-STOP
with detection of shorts across
contacts
S1
S22
S31
S32
S21
S12
S11
Safety gate
without detection of shorts
across contacts
S1
S22
S21
S12
S32
S11
S31
S1 S2
S22
S21
S11
S12
S32
Safety gate
with detection of shorts across
contacts
Light guard or safety switch, de-
tection of shorts across contacts
via ESPE
A2
GND
S21
S22
NOTICE
With single-channel wiring the safety level of your machine/plant may be
lower than the safety level of the unit (see Safety characteristic data).

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 14
NOTICE
Operation with a light guard or safety switch
It must not be possible to switch off the supply voltage for the PNOZ XV3P
separately from the supply voltage for the light guard or safety switch.
Start circuit
E-STOP wiring
Safety gate without start-up
test Safety gate with start-up test
Automatic start
S33
S34
S13
S14
S33
S13
S34
S14
Simultaneity S1 and S2: max. 3 s
Monitored start
S33
S34
S3
S14
S13
NOTICE
In the event of an automatic start:
The unit starts up automatically when the safeguard is reset, e.g. when the
E-STOP pushbutton is released. Use external circuit measures to prevent
an unexpected restart.
Reset delay time Without reset With reset
Link or N/C contact
Y39
Y40
Feedback loop Automatic start Monitored start
Contacts from external contactors
K5 K6
K5
L1
N
K6
S13
13 (23, 33)
S14
14 (24, 34)

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 15
Legend
}S1/S2: E-STOP/safety gate switch
}S3: Reset button
}: Switch operated
}: Gate open
}: Gate closed
INFORMATION
With automatic start, S33 and S34 must not be linked; with monitored start,
S13 and S14 must not be linked.
Operation
NOTICE
Check each safety function
– after initial commissioning and after each change of the machine/
plant
– for SIL CL 3/PL e at least 1x per month, for SIL CL 2/PL d at least 1x
per year
Follow the instructions below:
– Activate the safety function and check whether all the used safety
contacts open.
– Prepare for operation again and start the unit. All the used safety
contacts must be closed again.
The safety functions may only be checked by qualified personnel.
Status indicators
LEDs indicate the status and errors during operation:
LED on
POWER
Supply voltage is present.
START
Start circuit is closed.
CH.1
Safety contacts of channel 1 are closed.

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 16
CH.2
Safety contacts of channel 2 are closed.
CH.1 [t]
Channel 3 safety contacts are closed.
CH.2 [t]
Channel 4 safety contacts are closed.
Faults – Interference
}Earth fault: The supply voltage fails and the safety contacts open. Once the cause of
the respective fault has been rectified and the supply voltage is switched off for approx.
1minute, the unit is ready for operation again.
}Contact malfunctions: If the contacts have welded, reactivation will not be possible after
the input circuit has opened.
}LED "POWER" does not light: Short circuit or no supply voltage.
}In the case of an error, the delay-on de-energisation contacts may open before the
delay time has elapsed.
Dimensions in mm
* with spring-loaded terminals

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 17
Technical details
Order no. 777510 – 777514
See below for more order numbers
General 777510 777512 777514
Approvals
CCC, CE, EAC (Euras-
ian), TÜV, cULus Listed
CCC, CE, EAC (Euras-
ian), TÜV, cULus Listed
CCC, CE, EAC (Euras-
ian), TÜV, cULus Listed
Electrical data 777510 777512 777514
Supply voltage
Voltage 24 V 24 V 24 V
Kind DC DC DC
Voltage tolerance -15 %/+10 % -15 %/+10 % -15 %/+10 %
Output of external
power supply (DC) 4,5 W 4,5 W 4,5 W
Residual ripple DC 160 % 160 % 160 %
Duty cycle 100 % 100 % 100 %
Max. inrush current im-
pulse
Current pulse, A1 5 A 5 A 5 A
Pulse duration, A1 1 ms 1 ms 1 ms
Inputs 777510 777512 777514
Number 222
Voltage at
Input circuit DC 24 V 24 V 24 V
Start circuit DC 24 V 24 V 24 V
Feedback loop DC 24 V 24 V 24 V
Current at
Input circuit DC 35 mA 35 mA 35 mA
Start circuit DC 50 mA 50 mA 50 mA
Feedback loop DC 3,5 mA 3,5 mA 3,5 mA
Min. input resistance at
power-on 135 Ohm 135 Ohm 135 Ohm
Max. overall cable resist-
ance Rlmax
Single-channel at UB
DC 100 Ohm 100 Ohm 100 Ohm
Dual-channel without
detection of shorts
across contacts at UB
DC 100 Ohm 100 Ohm 100 Ohm
Dual-channel with de-
tection of shorts across
contacts at UB DC 10 Ohm 10 Ohm 10 Ohm

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 18
Relay outputs 777510 777512 777514
Number of output con-
tacts
Safety contacts (N/O),
instantaneous 333
Safety contacts (N/O),
delayed 222
Max. short circuit current
IK 1 kA 1 kA 1 kA
Utilisation category
In accordance with the
standard EN 60947-4-1 EN 60947-4-1 EN 60947-4-1
Utilisation category of
safety contacts
AC1 at 240 V 240 V 240 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 2000 VA 2000 VA 2000 VA
DC1 at 24 V 24 V 24 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 200 W 200 W 200 W
Utilisation category of
safety contacts delayed
AC1 at 240 V 240 V 240 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 2000 VA 2000 VA 2000 VA
DC1 at 24 V 24 V 24 V
Min. current 0,01 A 0,01 A 0,01 A
Max. current 8 A 8 A 8 A
Max. power 200 W 200 W 200 W
Utilisation category
In accordance with the
standard EN 60947-5-1 EN 60947-5-1 EN 60947-5-1
Utilisation category of
safety contacts
AC15 at 230 V 230 V 230 V
Max. current 5 A 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V 24 V
Max. current 7 A 7 A 7 A
Utilisation category of
safety contacts delayed
AC15 at 230 V 230 V 230 V
Max. current 5 A 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V 24 V
Max. current 7 A 7 A 7 A

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 19
Relay outputs 777510 777512 777514
Utilisation category in ac-
cordance with UL
Voltage 240 V AC G. P. 240 V AC G. P. 240 V AC G. P.
With current 8 A 8 A 8 A
Voltage 24 V DC Resistive 24 V DC Resistive 24 V DC Resistive
With current 5 A 5 A 5 A
Pilot Duty C300, R300 C300, R300 C300, R300
External contact fuse pro-
tection, safety contacts
In accordance with the
standard EN 60947-5-1 EN 60947-5-1 EN 60947-5-1
Max. melting integral 240 A²s 240 A²s 240 A²s
Blow-out fuse, quick 10 A 10 A 10 A
Blow-out fuse, slow 6 A 6 A 6 A
Blow-out fuse, gG 10 A 10 A 10 A
Circuit breaker 24V
AC/DC, characteristic
B/C 6 A 6 A 6 A
External contact fuse pro-
tection, delayed safety
contacts
Max. melting integral 240 A²s 240 A²s 240 A²s
Blow-out fuse, quick 10 A 10 A 10 A
Blow-out fuse, slow 6 A 6 A 6 A
Blow-out fuse, gG 10 A 10 A 10 A
Circuit breaker 24 V
AC/DC, characteristic
B/C 6 A 6 A 6 A
Contact material AgSnO2 + 0,2 µm Au AgSnO2 + 0,2 µm Au AgSnO2 + 0,2 µm Au
Conventional thermal
current while loading
several contacts
777510 777512 777514
Ith per contact at UB DC;
AC1:240V,DC1:24V
Conv. therm. current
with 1 contact 8 A 8 A 8 A
Conv. therm. current
with 2 contacts 6,8 A 6,8 A 6,8 A
Conv. therm. current
with 3 contacts 5,5 A 5,5 A 5,5 A
Conv. therm. current
with 4 contacts 4,8 A 4,8 A 4,8 A
Conv. therm. current
with 5 contacts 4,3 A 4,3 A 4,3 A

PNOZ XV3P
Operating Manual PNOZ XV3P
20122-EN-05 20
Times 777510 777512 777514
Switch-on delay
With automatic start
typ. 350 ms 350 ms 350 ms
With automatic start
max. 650 ms 650 ms 650 ms
With automatic start
after power on typ. 385 ms 385 ms 385 ms
With automatic start
after power on max. 700 ms 700 ms 700 ms
With monitored start
typ. 35 ms 35 ms 35 ms
With monitored start
max. 70 ms 70 ms 70 ms
Delay-on de-energisation
With E-STOP typ. 15 ms 15 ms 15 ms
With E-STOP max. 30 ms 30 ms 30 ms
With power failure typ. 85 ms 85 ms 85 ms
With power failure max. 200 ms 200 ms 200 ms
Recovery time at max.
switching frequency 1/s
After E-STOP 50 ms +tv 50 ms +tv 50 ms +tv
After power failure 250 ms 250 ms 250 ms
Delay time tv 0,1 s, 0,5 s, 1 s, 2 s, 4 s,
6 s, 8 s, 10 s, 15 s, 20 s,
25 s, 30 s
0,1 s, 0,2 s, 0,3 s, 0,4 s,
0,5 s, 0,6 s, 0,7 s, 0,8 s, 1
s, 1,5 s, 2 s, 3 s 0,5 s
Time accuracy -15 %/+15 % +50 ms -15 %/+15 % +50 ms -15 %/+15 % +50 ms
Repetition accuracy 2 % 2 % 2 %
Waiting period with a
monitored start 300 ms 300 ms 300 ms
Min. start pulse duration
with a monitored start 30 ms 30 ms 30 ms
Supply interruption before
de-energisation 20 ms 20 ms 20 ms
Simultaneity, channel 1
and 2 max. ∞∞∞
Environmental data 777510 777512 777514
Climatic suitability EN 60068-2-78 EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -10 - 55 °C -10 - 55 °C -10 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C -40 - 85 °C
Climatic suitability
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation during op-
eration Not permitted Not permitted Not permitted
EMC EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
EN 60947-5-1, EN
61000-6-2, EN 61326-3-1
Table of contents
Other Pilz Relay manuals

Pilz
Pilz PNOZ X3.1 User manual

Pilz
Pilz P2HZ X1 User manual

Pilz
Pilz PNOZ X2.7P User manual

Pilz
Pilz PNOZ Ex Series User manual

Pilz
Pilz PNOZ c1 User manual

Pilz
Pilz PZA Series User manual

Pilz
Pilz PNOZ s1 User manual

Pilz
Pilz PNOZ X3 User manual

Pilz
Pilz PNOZ XV3.1P User manual

Pilz
Pilz PNOZ XV3.1 User manual

Pilz
Pilz PNOZ mc0p User manual

Pilz
Pilz PNOZ s7.2 User manual

Pilz
Pilz PNOZ 11 User manual

Pilz
Pilz PNOZ po3.1p User manual

Pilz
Pilz PZE X4.1P User manual

Pilz
Pilz PNOZ s30 User manual

Pilz
Pilz PNOZ X9P AC/DC User manual

Pilz
Pilz PNOZ X2.5P Series User manual

Pilz
Pilz PNOZ e3vp User manual

Pilz
Pilz PNOZ e4.1p User manual