Pilz PSWZ X1P User manual

Safe monitoring relays
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Up to PL e of EN ISO 13849-1
PSWZ X1P
NSG-D-2-336-2009-11
Gertebild
][Bildunterschrift_Stillstandswchter
Standstill monitor for safe standstill
monitoring
Approvals
Zulassungen
Unit features
Gertemerkmale
`Positive-guided relay outputs:
– 2 safety contacts (N/O), instanta-
neous
– 1 auxiliary contact (N/C), instan-
taneous
`LED indicator for:
– Supply voltage
– Standstill on channel 1/2
–Switchstatus
– Fault signal if simultaneity time is
exceeded
`Semiconductor outputs signal:
– Error
–Switchstatus
`Semiconductor input for reset func-
tion
`Measuring inputs for single or
three-phase motors
`Measuring voltage selectable
`Feedback loop
`Plug-in connection terminals (either
spring-loaded terminal or screw
terminal)
`See order reference for unit types
Unit description
Gertebeschreibung
The unit is used for safe standstill
monitoring. It is designed for use on
`Standstill monitoring functions on
plants with dangerous machine
parts or tools (EN 1088 clause 7.4),
`Safety circuits in accordance with
EN 60204-1 and IEC 60204-1.
Standstill is only detected on power-
free measuring circuits. Residual volt-
ages, induced voltages or drives with-
in the position control will prevent safe
standstill detection!
Safety features
][Sicherheitseigenschaften Stillstand
`Relays K1 and K2 are interlocked in
such a way that the unit cannot be
switched back on in the case of
contact welding or an open circuit.
`The unit monitors the measuring
circuits for open circuit. If an open
circuit occurs between the unit and
the motor or on the motor itself, the
unit immediately switches off.
`The standstill monitor prevents the
plant from being enabled in the fol-
lowing cases
– Power supply failure
– Component failure
– Measuring circuits are open cir-
cuit
– Coil defect/open circuit
Block diagram
Blockschaltbild
PSWZ X1P
SÜDDEUTSCHLAND
A1 A2
=
Power
~
K1
K2
Input
L1 13 23 41
14 24 42
L2 L3
Reset
RESET
Feed-
back
0 V 24 V
Y30 Y31 Y32 Y35Y1 Y2

Safe monitoring relays
Up to PL e of EN ISO 13849-1
PSWZ X1P
NSG-D-2-336-2009-11Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-2
Function description
][Funktionen_einkanalig_Stillstand
The device uses two separate measur-
ing channels to measure the regener-
ated voltage, induced from the motor
during the rundown period or during
start-up. If the voltage falls below the
set response value (standstill thresh-
old), the standstill monitor enables the
monitored plant. If the voltage ex-
ceeds the set release value, the stand-
still monitor disables the monitored
plant.
To reactivate, the voltage at both
channels must fall below the response
value Uon within the time tg(simultane-
ity monitoring). To do this the feed-
back loop Y1-Y2 must be closed. If the
simultaneity requirement is exceeded,
the standstill monitor does not enable
the monitored plant. The unit can be
reactivated by switching 24 VDC on
and off at the RESET input.
The response value Uon can be set
jointly for both channels in order to suit
the motor that is to be monitored. The
release value Uoff (hysteresis) corre-
sponds to twice the response value.
When used with frequency converters,
the PSWZ X1P cannot detect standstill
until the controller inhibit has been
switched off.
After the supply voltage is switched
on, the unit performs a self test. The
unit simulates a situation in which the
release value is exceeded and the
measuring circuit has an open circuit.
The correct function of the output relay
and feedback loop is also tested. The
test takes ca. 1.5 s.
][Funktionen_zweikanalig_Stillstand
Operating modes:
`Single-channel operation:
– One measuring circuit affects
both channels
– No redundancy (failsafe) in the
measuring circuits
`Dual-channel operation:
– Two redundant (identical) meas-
uring circuits affect channel 1
and 2
– Monitoring of voltages in the
measuring circuit (failsafe in the
event of a short circuit)
Timing diagram
Zeitdiagramm
Key
`POWER: Supply voltage
`UL1/UL2: Input circuitL1, L2, L3
`Feedback: Feedback loop Y1-Y2
`Output safe: Safety contacts 13-14,
23-24
`Output aux: Auxiliary contact 41-42
`Semi Y35: Semiconductor output
for fault signal
`RESET: Reset input RESET
`Uon: Response value
`Uoff: Release value
`tg: Simultaneity
Wiring
][Verdrahtung_Si_unverz_1Hi_unverz_Stillstand
Please note:
`Information given in the “Technical
details” must be followed.
`Outputs 13-14, 23-24 are safety
contacts, output 41-42 is an auxilia-
ry contact (e.g. for display).
`To prevent contact welding, a fuse
should be connected before the
output contacts (see technical de-
tails).
`Use copper wire that can withstand
60/75 °C.
`When used with converters: Use
screened cable for the wiring be-
tween the standstill monitor and the
motor. Connect the cable screening
on the motor.
POWER
Semi Y35
Output safe
Feedback
t < tg1,5 s
t > tg
RESET
L1/ L2
on
off
50 ms
Output aux

Safe monitoring relays
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Up to PL e of EN ISO 13849-1
PSWZ X1P
NSG-D-2-336-2009-11
Preparing for operation
Betriebsbereitschaft herstellen
`Supply voltage
`Input circuit
`Feedback loop
`Semiconductor output
`Semiconductor input
Supply voltage AC DC
A1 L1
N
A2
A1 L+
A2 L-
Input circuit Single-phase motor Three-phase motor
L1
M
~
L2
L3
L1
N
L1
M
~
L2
L3
L1
L2
L3
Contacts from external contactors or link
K5 K6
K5 L1
N
K6
Y1
13 (23)
Y2
14 (24)
Y1
Y2
Y32: Semiconductor output for switch sta-
tus
Y35: Semiconductor output for fault signal
Y31
Y32
24 V DC
SPS Input
0 V
Y30
Y35 SPS Input
RESET
SPS Output
Y30
0 V

Safe monitoring relays
Up to PL e of EN ISO 13849-1
PSWZ X1P
NSG-D-2-336-2009-11Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-4
Terminal configuration
Klemmenbelegung
Installation
Montage_PNOZ_X
`The safety relay should be installed
in a control cabinet with a protec-
tion type of at least IP54.
`Use the notch on the rear of the unit
to attach it to a DIN rail.
`Ensure the unit is mounted securely
on a vertical DIN rail (35 mm) by us-
ing a fixing element (e.g. retaining
bracket or an end angle).
Dimensions
Abmessungen
* with spring-loaded terminals
45
(1.77")
121 (4.76")
* 101 (3.98")
94 (3.70")

Safe monitoring relays
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Up to PL e of EN ISO 13849-1
PSWZ X1P
NSG-D-2-336-2009-11
Notice
][WICHTIG_PDB_alt
This data sheet is only intended for use
during configuration. For installation
and operation, please refer to the op-
erating instructions supplied with the
unit.
Service life graph
Lebensdauerkurve
Technische Daten
10
1
10 100 1000 10000
0.1
DC13: 24 V
AC15: 230 V
AC1: 230 V
DC1: 24 V
D Nennbetriebstrom (A)
GB Nominal operating urrent (A)
F Courant oupé (A)
E Corriente nominal de servi io (A)
I Corrente di eser izio nominale (A)
NL Nominale bedrijfsstroom (A)
D S haltspielzahl x 10
3
GB Cy les x 10
3
F Nombre de manuvres x 10
3
E Número de i los x 10
3
I Numero dei i li di ommutazione x 10
3
NL Aantal s hakelingen x 10
3
Technical details
Electrical data
Supply voltage
Supply voltage UBAC/DC 24 - 240 V
Voltage tolerance -15 %/+10 %
Power consumption at UBAC 5.0 VA
Power consumption at UBDC 3.0 W
Frequency range AC 50 - 60 Hz
Residual ripple DC 160 %
Voltage and current at
Feedback loop DC: 24.0 V 35.0 mA
Number of output contacts
Safety contacts (S) instantaneous: 2
Auxiliary contacts (N/C): 1
Utilisation category in accordance with EN 60947-4-1
Safety contacts: AC1 at 240 V Imin:0.01 A , Imax:6.0 A
Pmax: 1500 VA
Safety contacts: DC1 at 24 V Imin: 0.01 A , Imax: 6.0 A
Pmax: 150 W
Auxiliary contacts: AC1 at 240 V Imin: 0.01 A , Imax: 6.0 A
Pmax: 1500 VA
Auxiliary contacts: DC1 at 24 V Imin: 0.01 A , Imax: 6.0 A
Pmax: 150 W
Utilisation category in accordance with EN 60947-5-1
Safety contacts: AC15 at 230 V Imax: 3.0 A
Safety contacts: DC13 at 24 V (6 cycles/min) Imax: 4.0 A
Auxiliary contacts: AC15 at 230 V Imax: 3.0 A
Auxiliary contacts: DC13 at 24 V (6 cycles/min) Imax: 4.0 A
Contact material AgCuNi + 0.2 µm Au

Safe monitoring relays
Up to PL e of EN ISO 13849-1
PSWZ X1P
NSG-D-2-336-2009-11Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
-6
External contact fuse protection (IK= 1 kA) to EN 60947-5-1
Blow-out fuse, quick
Safety contacts: 6 A
Auxiliary contacts: 6 A
Blow-out fuse, slow
Safety contacts: 4 A
Auxiliary contacts: 4 A
Circuit breaker 24 VAC/DC, characteristic B/C
Safety contacts: 4 A
Auxiliary contacts: 4 A
Semiconductor outputs (short circuit proof) 24.0 V DC,50 mA
External supply voltage 24.0 V DC
Voltage tolerance -20 %/+20 %
Semiconductor input
High 15 V DC
Low 5 V DC
Input current 20 mA
Measuring circuit
Input voltage L1-L3, L1-L2, L2-L3 0 - 690 VAC/DC
Input voltage in accordance with UL 0 - 600 VAC
Frequency range AC 0 - 3000 Hz
Input impedance 1300 kOhm
Switching threshold per channel
Response value Uon 120 - 3000 mV Order no.: 777950, 787950
20 - 500 mV Order no.: 777949, 777959, 787949
7.5 - 500 mV Order no.: 777951, 787951
Release value Uoff 2 x Uon
Max. inrush current 10.00 A
Safety-related characteristic data
PL in accordance with EN ISO 13849-1 PL e (Cat. 4)
Category in accordance with EN 954-1 Cat. 4
SIL CL in accordance with EN IEC 62061 SIL CL 3
PFH in accordance with EN IEC 62061 6.23E-09
SIL in accordance with IEC 61511 SIL 3
PFD in accordance with IEC 61511 6.47E-05
tMin years 20
Times
Switch-on delay
with automatic reset typ. 1,500 ms
with automatic reset after power on max. 2,200 ms
Delay-on de-energisation after motor on max. 170 ms
Recovery time at max. switching frequency 1/s
after power failure 2200 ms
Simultaneity, channel 1 and 2 7 s
Supply interruption before de-energisation 20 ms
Environmental data
EMC EN 60947-5-1, EN 61000-6-2, EN 61000-6-4
Vibration to EN 60068-2-6
Frequency 10 - 55 Hz
Amplitude 0.35 mm
Climatic suitability EN 60068-2-78
Airgap creepage in accordance with EN 60947-1
Pollution degree 2
Overvoltage category III
Rated insulation voltage 250 V
Rated impulse withstand voltage 4.00 kV
Ambient temperature -10 - 55 °C
Electrical data

Safe monitoring relays
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Up to PL e of EN ISO 13849-1
PSWZ X1P
NSG-D-2-336-2009-11
Technische Daten_Satz Normen
The standards current on 2008-07 apply.
Bestelldaten
Storage temperature -40 - 85 °C
Protection type
Mounting (e.g. cabinet) IP54
Housing IP40
Terminals IP20
Mechanical data
Housing material
Housing PPO UL 94 V0
Front ABS UL 94 V0
Cross section of external conductors with screw terminals
1 core flexible 0.25 - 2.50 mm² , 24 - 14 AWG Order no.: 777949, 777950,
777951, 777959
2 core, same cross section, flexible:
with crimp connectors, without insulating sleeve 0.25 - 1.00 mm² , 24 - 16 AWG Order no.: 777949, 777950,
777951, 777959
without crimp connectors or with TWIN crimp connectors 0.50 - 1.50 mm² , 24 - 16 AWG Order no.: 777949, 777950,
777951, 777959
Torque setting with screw terminals 0.60 Nm Order no.: 777949, 777950, 777951, 777959
Cross section of external conductors with spring-loaded termi-
nals: Flexible with/without crimp connectors
0.20 - 1.50 mm² , 24 - 16 AWG Order no.: 787949, 787950,
787951
Spring-loaded terminals: Terminal points per connection 2Order no.: 787949, 787950, 787951
Stripping length 8 mm Order no.: 787949, 787950, 787951
Dimensions
Height 101.0 mm Order no.: 787949, 787950, 787951
94.0 mm Order no.: 777949, 777950, 777951, 777959
Width 45.0 mm
Depth 121.0 mm
Weight 315 g Order no.: 787949, 787950, 787951
320 g Order no.: 777949, 777950, 777951, 777959
Environmental data
Order reference
Type Features Terminals Order no.
PSWZ X1P C 24 - 240 VAC/DC 0.02 - 0.5 V Spring-loaded terminals 787 949
PSWZ X1P 24 - 240 VAC/DC 0.02 - 0.5 V Screw terminals 777 949
PSWZ X1P C 24 - 240 VAC/DC 0.12 - 3 V Spring-loaded terminals 787 950
PSWZ X1P 24 - 240 VAC/DC 0.12 - 3 V Screw terminals 777 950
PSWZ X1P C 24 - 240 VAC/DC 0.0075 – 0.5 V Spring-loaded terminals 787 951
PSWZ X1P 24 - 240 VAC/DC 0.0075 – 0.5 V Screw terminals 777 951
PSWZ X1P
(coated version)
24 - 240 VAC/DC 0.02 - 0.5 V Screw terminals 777 959
Other manuals for PSWZ X1P
3
Table of contents
Other Pilz Relay manuals

Pilz
Pilz PNOZsigma Instructions for use

Pilz
Pilz PNOZ p1p User manual

Pilz
Pilz P1HZ 2 User manual

Pilz
Pilz PNOZ X3.10P User manual

Pilz
Pilz PNOZ 2VQ User manual

Pilz
Pilz PNOZ XV3.1P User manual

Pilz
Pilz PNOZ s8 User manual

Pilz
Pilz PNOZ e4.1p User manual

Pilz
Pilz P2HZ X3 User manual

Pilz
Pilz PNOZ XV2.1 User manual

Pilz
Pilz PNOZ s30 User manual

Pilz
Pilz PNOZ X1 User manual

Pilz
Pilz PNOZ X3P User manual

Pilz
Pilz PNOZ X10.11P User manual

Pilz
Pilz PNOZ X2.1VP User manual

Pilz
Pilz PNOZ X1P User manual

Pilz
Pilz PNOZ X2C User manual

Pilz
Pilz PNOZ X Series User manual

Pilz
Pilz PNOZ s7 User manual

Pilz
Pilz PNOZ X2.8P User manual