Pilz P2HZ X1.10P User manual

P2HZ X1.10P
Operating Manual-20817-EN-07
}Safety relays

Preface
This document is the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for the user's internal purposes. Suggestions and comments for improving this documenta-
tion will be gratefully received.
Source code from third-party manufacturers or open source software has been used for
some components. The relevant licence information is available on the Internet on the Pilz
homepage.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries.
SD means Secure Digital

Contents
Operating Manual P2HZ X1.10P
20817-EN-07 | 3
Introduction ............................................................................................................................4
Validity of documentation.......................................................................................................... 4
Using the documentation .......................................................................................................... 4
Definition of symbols................................................................................................................. 4
Safety ...................................................................................................................................... 5
Intended use ............................................................................................................................. 5
Safety regulations ..................................................................................................................... 5
Safety assessment ................................................................................................................... 5
Use of qualified personnel ........................................................................................................ 6
Warranty and liability ................................................................................................................ 6
Disposal .................................................................................................................................... 6
For your safety.......................................................................................................................... 6
Unit features ...........................................................................................................................6
Safety features ....................................................................................................................... 7
Block diagram/terminal configuration ................................................................................. 8
Function Description ............................................................................................................. 8
Operating modes ...................................................................................................................... 9
Timing diagram ......................................................................................................................... 9
Installation ..............................................................................................................................9
Wiring ......................................................................................................................................10
Preparing for operation ......................................................................................................... 11
Operation ................................................................................................................................11
Status indicators ....................................................................................................................... 12
Faults – Interference .............................................................................................................. 12
Dimensions in mm .................................................................................................................12
Technical details ....................................................................................................................13
Safety characteristic data ..................................................................................................... 17
Supplementary data ..............................................................................................................18
Service life graph ...................................................................................................................... 18
Order reference ......................................................................................................................19
EC declaration of conformity ................................................................................................ 19

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 4
Introduction
Validity of documentation
This documentation is valid for the product P2HZ X1.10P. It is valid until new documenta-
tion is published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
Using the documentation
This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.
Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
NOTICE
This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 5
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The two-hand control relay P2HZ X1.10P meets the requirements of EN 574 Type III C. It
forces a press operator to keep his hands out of the hazardous area during the dangerous
closing movement, so avoiding hand injuries.
The P2HZ X1.10P is suitable for use on controllers for metalworking presses as a block for
simultaneity.
The device can be used as a hand protection device in accordance with the following tech-
nical regulations:
}Mechanical presses (EN 692)
}Hydraulic presses (EN 693)
}Fly presses (EN 692)
or safety circuits in accordance with EN60204- 1.
The supply voltage for the two-hand control relay must only be connected downstream of
the shutdown device in accordance with §9VBG7n5.1/2.
The following is deemed improper use in particular
}Any component, technical or electrical modification to the product,
}Use of the product outside the areas described in this manual,
}Use of the product outside the technical details (see Technical details [ 17]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a device, a safety assessment in accordance with the Machinery Directive is
required.

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 6
The product as an individual component fulfils the functional safety requirements in accord-
ance with EN ISO 13849 and EN 62061. However, this does not guarantee the functional
safety of the overall plant/machine. To achieve the relevant safety level of the overall plant/
machine’s required safety functions, each safety function needs to be considered separ-
ately.
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by persons who are competent to do so.
A competent person is a qualified and knowledgeable person who, because of their train-
ing, experience and current professional activity, has the specialist knowledge required. To
be able to inspect, assess and operate devices, systems and machines, the person has to
be informed of the state of the art and the applicable national, European and international
laws, directives and standards.
It is the company’s responsibility only to employ personnel who
}Are familiar with the basic regulations concerning health and safety / accident prevention,
}Have read and understood the information provided in the section entitled Safety
}Have a good knowledge of the generic and specialist standards applicable to the specific
application.
Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended,
}Damage can be attributed to not having followed the guidelines in the manual,
}Operating personnel are not suitably qualified,
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Disposal
}In safety-related applications, please comply with the mission time TM in the safety-related
characteristic data.
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
For your safety
The unit meets all the necessary conditions for safe operation. However, please note the
following:
}Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120
VDC) are present on the unit, connected control elements and sensors must have a rated
insulation voltage of at least 250 V.
Unit features
}Positive-guided relay outputs:
– 3 safety contacts (N/O), instantaneous

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 7
– 1 auxiliary contact (N/C), instantaneous
}2 semiconductor outputs
}Connection options for:
– 2 control elements (pushbuttons)
}LED display for:
– Supply voltage
– Switch status of the safety contacts
}Semiconductor outputs signal:
– Supply voltage is present
– Switch status of the safety contacts
}Plug-in connection terminals (either spring-loaded terminal or screw terminal)
Safety features
The two-hand control relay meets the following safety requirements:
}The circuit is redundant with built-in self-monitoring.
}The safety function remains effective in the case of a component failure.
}The circuit prevents a further press stroke in the case of:
– Relay failure
– Contact welding
– Coil defect on a relay
– Open circuit
– Short circuit

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 8
Block diagram/terminal configuration
Y30
A2
Y32 Y35Y31
X4
A2
P4
14
CH.2
X3
P2HZ X1.10P
S11
A1
S12 S13 S21
X2
POWER
CH.1
P4
X1
Y2Y1A1 13
P3
23
S22
41 42
3424
S21
P3
S23
S22 S23
S12
S13
S11
33
*Insulation between the non-marked area and the relay contacts: Basic insulation (over-
voltage category III), Protective separation (overvoltage category II)
Function Description
The two-hand control relay P2HZ X1.10P is activated by simultaneously operating the two
operator elements (simultaneity see Technical details [ 17]). If one or both of the oper-
ator elements are released, it interrupts the control command to close the press. The
device is ready for operation when the supply voltage is applied and the feedback loop Y1-
Y2 is closed. The "POWER" LED lights up.
}Both operator elements are operated within the simultaneity:
– Safety contacts 13-14, 23-24 and 33-34 close, auxiliary contact 41-42 is opened, the
device is active.
– LEDs "CH1" and "CH2" will light.
– A high signal is present at the semiconductor output switch state Y32.
}One operator element is released following simultaneous operation:
– Safety contacts 13-14, 23-24 and 33-34 are opened redundantly, auxiliary contact
41-42 is closed.
– The LED "CH1" or "CH2" goes out.
– A low signal is present at the semiconductor output switch state Y32.
}To activate the device again, both operator elements have to be released and then oper-
ated again within the simultaneity.
Semiconductor output supply voltage Y35:
}A high signal is present at semiconductor output Y35 if the supply voltage is present and
the internal fuse has not blown.

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 9
Operating modes
}Dual-channel operation with detection of shorts across contacts: Redundant input circuit,
P2HZ X1.10P detects
– earth faults in the start and input circuit,
– short circuits in the input circuit,
– shorts across contacts in the input circuit.
Timing diagram
POWER
Feedback loop
Output safe
Button 1
t0t1t2t3t3t1
Button 2
Out semi CH
Output aux.
Out semi RUN
t1
Legend
}POWER: Supply voltage
}Button 1/Button 2: Pushbutton in the input circuit
}Feedback loop: Feedback loop
}Output safe: Safety outputs
}Output aux: Auxiliary contact
}Out semi RUN: Semiconductor output supply voltage
}Out semi CH: Semiconductor output switch state
}t0: Recovery time after power on
}t1: Simultaneity, channel 1 and 2
}t2: Operating cycle ended through pushbutton 1 or 2
}t3: Y1-Y2 must be closed before the button is operated (recovery time)
Shaded area: State irrelevant
Installation
}The unit should be installed in a control cabinet with a protection type of at least IP54.
}Use the notch on the rear of the unit to attach it to a DIN rail (35 mm).
}When installed vertically: Secure the unit by using a fixing element (e.g. retaining bracket
or end angle).

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 10
WARNING!
Loss of the safety function due to too short distance of the operator
elements to the hazardous area!
The distance of the two-hand control relay to the nearest hazardous area
must be large enough so that if one of the operator elements is released,
the hazardous movement is interrupted before the operator reaches the
hazardous area or can reach into the hazardous area. You must maintain
the minimum distance in accordance with EN ISO 13855.
Depending on the application, serious injury or death may result.
Wiring
Please note:
}Information given in the "Technical details [ 17]" must be followed.
}Outputs 13-14, 23-24, 33-34 are safety contacts; output 41-42 is an auxiliary contact (e.g.
for display).
}Do not use auxiliary contacts 41-42 and semiconductor outputs Y32 and Y35 for safety
circuits!
}To prevent contact welding, a fuse should be connected before the output contacts (see
Technical details [ 17]).
}Calculation of the max. cable length lmax in the input circuit:
Rlmax
Rl / km
Imax =
Rlmax = max. overall cable resistance (see Technical details [ 17])
Rl/km = cable resistance/km
}Use copper wiring with a temperature stability of 60/75 °C.
}To prevent EMC interferences (particularly common-mode interferences) the measures
described in EN60204-1 must be executed. This includes the separate routing of cables
of the control circuits (input, start and feedback loop) from other cables for energy trans-
mission or the shielding of cables, for example.
}The supply voltage must be switched off with the operating energy of the machine.
}The connection cables between the P2HZ X1.10P and the pushbuttons should not be laid
directly next to power cables, otherwise inductive and capacitive interference coupling
can result.
}On account of the low currents you should use gold-plated pushbutton contacts.
}Only contactors with positive-guided contacts should be used for safety functions.
}Adequate protection must be provided on all output contacts with capacitive and inductive
loads.
}Do not switch low currents using contacts that have been used previously with high cur-
rents.
}The power supply must comply with the regulations for extra low voltages with protective
electrical separation (SELV, PELV) in accordance with VDE 0100, Part 410.

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 11
Preparing for operation
Supply voltage AC DC
A1
A2
L1
N
F1
A1
F1
A2
L+
L-
Input circuit Single-channel Dual-channel
Two-hand pushbuttons
with detection of shorts across
contacts
S22
S21
S12
S11
S13
S23
S1
S2
Feedback loop without feedback loop monitor-
ing
with feedback loop monitoring
Link or contacts from external
contactors
Semiconductor output
PLC
PLC
Legend
}S1/S2: Two-hand pushbuttons
Operation
When the relay outputs are switched on, the mechanical contact on the relay cannot be
tested automatically. Depending on the operational environment, measures to detect the
non-opening of switching elements may be required under some circumstances.
When the product is used in accordance with the European Machinery Directive, a check
must be carried out to ensure that the safety contacts on the relay outputs open correctly.
Open the safety contacts (switch off output) and start the device again, so that the internal
diagnostics can check that the safety contacts open correctly
}for SIL CL 3/PL e at least 1x per month
}for SIL CL 2/PL d at least 1x per year

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 12
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Status indicators
LEDs indicate the status and errors during operation:
LED on
POWER
Supply voltage is present and E-STOP pushbutton not operated.
CH.1
Safety contacts of channel 1 are closed.
CH.2
Safety contacts of channel 2 are closed.
Faults – Interference
}Contact malfunctions: If the contacts have welded, reactivation will not be possible after
the input circuit has opened.
Dimensions in mm
121 (4.76")
75 (2.95")
87 (3.42")
45
(1.77")

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 13
Technical details
General 777341 787341
Certifications
CCC, CE, EAC (Eurasian), TÜV,
cULus Listed
CCC, CE, EAC (Eurasian), TÜV,
cULus Listed
Electrical data 777341 787341
Supply voltage
Voltage 24 V 24 V
Kind DC DC
Voltage tolerance -15 %/+10 % -15 %/+10 %
Output of external power supply
(DC) 2,5 W 2,5 W
Residual ripple DC 10 % 10 %
Duty cycle 100 % 100 %
Current at
Normally open contact 30 mA 30 mA
N/C 20 mA 20 mA
Max. overall cable resistance Rl-
max per input circuit 14 Ohm 14 Ohm
External unit fuse protection F1
min. 1 A 1 A
External unit fuse protection F1
max. Max. conductor cross section Max. conductor cross section
Two-hand control relay type
In accordance with the standard EN 574 EN 574
Type III C III C
Inputs 777341 787341
Number 2 2
Voltage at
Input circuit DC 24 V 24 V
Feedback loop DC 24 V 24 V
Current at
Feedback loop DC 45 mA 45 mA
Semiconductor outputs 777341 787341
Number 2 2
Voltage 24 V 24 V
Current 20 mA 20 mA
External supply voltage 24 V 24 V
Voltage tolerance -15 %/+10 % -15 %/+10 %
Residual current at "0" signal 0,1 mA 0,1 mA
Max. internal voltage drop 4 V 4 V
Conditional rated short circuit cur-
rent 100 A 100 A
Lowest operating current 0 mA 0 mA
Utilisation category in accordance
with EN 60947-1 DC-12 DC-12

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 14
Relay outputs 777341 787341
Number of output contacts
Safety contacts (N/O), instant-
aneous 3 3
Auxiliary contacts (N/C) 1 1
Max. short circuit current IK 1 kA 1 kA
Utilisation category
In accordance with the standard EN 60947-4-1 EN 60947-4-1
Utilisation category of safety con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 5 A 5 A
Max. power 1250 VA 1250 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 5 A 5 A
Max. power 125 W 125 W
Utilisation category of auxiliary con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 500 VA 500 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 50 W 50 W
Utilisation category
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Utilisation category of safety con-
tacts
AC15 at 230 V 230 V
Max. current 2,5 A 2,5 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 1,5 A 1,5 A
Utilisation category of auxiliary con-
tacts
AC15 at 230 V 230 V
Max. current 2 A 2 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 1,5 A 1,5 A

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 15
Relay outputs 777341 787341
Utilisation category in accordance
with UL
Voltage 240 V AC G. P. 240 V AC G. P.
With current 5 A 5 A
Voltage 24 V DC Resistive 24 V DC Resistive
With current 5 A 5 A
Pilot Duty C300, R300 C300, R300
External contact fuse protection,
safety contacts
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Max. melting integral 240 A²s 240 A²s
Blow-out fuse, quick 6 A 6 A
Blow-out fuse, slow 4 A 4 A
Blow-out fuse, gG 6 A 6 A
Circuit breaker 24V AC/DC,
characteristic B/C 4 A 4 A
External contact fuse protection,
auxiliary contacts
Max. melting integral 240 A²s 240 A²s
Blow-out fuse, quick 4 A 4 A
Blow-out fuse, slow 2 A 2 A
Blow-out fuse, gG 4 A 4 A
Circuit breaker 24 V AC/DC,
characteristic B/C 2 A 2 A
Conventional thermal current 5 A 5 A
Contact material AgSnO2 + 0,2 µm Au AgSnO2 + 0,2 µm Au
Times 777341 787341
Delay-on de-energisation (re-
sponse time in accordance with EN
574)
Normally open contact 15 ms 15 ms
N/C 30 ms 30 ms
Recovery time 250 ms 250 ms
Supply interruption before de-ener-
gisation 150 ms 150 ms
Simultaneity, channel 1 and 2 max. 500 ms 500 ms
Environmental data 777341 787341
Climatic suitability EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -25 - 55 °C -25 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C
Climatic suitability
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation during operation Not permitted Not permitted
EMC EN 60947-5-1, EN 61000-6-2 EN 60947-5-1, EN 61000-6-2

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 16
Environmental data 777341 787341
Vibration
In accordance with the standard EN 60068-2-6 EN 60068-2-6
Frequency 10 - 55 Hz 10 - 55 Hz
Amplitude 0,35 mm 0,35 mm
Airgap creepage
In accordance with the standard EN 60947-1 EN 60947-1
Overvoltage category III / II III / II
Pollution degree 2 2
Rated insulation voltage 250 V 250 V
Rated impulse withstand voltage 4 kV 4 kV
Protection type
Housing IP40 IP40
Terminals IP20 IP20
Mounting area (e.g. control cab-
inet) IP54 IP54
Mechanical data 777341 787341
Mounting position Any Any
Mechanical life 10,000,000 cycles 10,000,000 cycles
Material
Bottom PPO UL 94 V0 PPO UL 94 V0
Front ABS UL 94 V0 ABS UL 94 V0
Top PPO UL 94 V0 PPO UL 94 V0
Connection type Screw terminal Spring-loaded terminal
Mounting type plug-in plug-in
Conductor cross section with screw
terminals
1 core flexible 0,25 - 2,5 mm², 24 - 12 AWG –
2 core with the same cross sec-
tion, flexible with crimp connect-
ors, no plastic sleeve 0,25 - 1 mm², 24 - 16 AWG –
2 core with the same cross sec-
tion, flexible without crimp con-
nectors or with TWIN crimp con-
nectors 0,2 - 1,5 mm², 24 - 16 AWG –
Torque setting with screw terminals 0,5 Nm –
Stripping length with screw termin-
als 8 mm –
Conductor cross section with
spring-loaded terminals: Flexible
with/without crimp connector – 0,2 - 1,5 mm², 24 - 16 AWG
Spring-loaded terminals: Terminal
points per connection – 2
Stripping length with spring-loaded
terminals – 8 mm

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 17
Mechanical data 777341 787341
Dimensions
Height 94 mm 101 mm
Width 45 mm 45 mm
Depth 121 mm 121 mm
Weight 290 g 285 g
Where standards are undated, the 2020-07 latest editions shall apply.
Safety characteristic data
NOTICE
You must comply with the safety characteristic data in order to achieve the
required safety level for your plant/machine.
Operating
mode
EN ISO
13849-1:
2015
PL
EN ISO
13849-1:
2015
Category
EN62061
SIL CL
EN62061
PFHD [1/h]
IEC 61511
SIL
IEC 61511
PFD
EN ISO
13849-1:
2015
TM [year]
–PL e Cat. 4 SIL CL 3 3,01E-09 SIL 3 3,24E-06 20
Explanatory notes for the safety-related characteristic data:
}The SIL CL value in accordance with EN 62061 corresponds to the SIL value in accord-
ance with EN 61508.
}TM is the maximum mission time in accordance with EN ISO 13849-1. The value also ap-
plies as the retest interval in accordance with EN 61508-6 and IEC 61511 and as the
proof test interval and mission time in accordance with EN 62061.
All the units used within a safety function must be considered when calculating the safety
characteristic data.
INFORMATION
A safety function's SIL/PL values are not identical to the SIL/PL values of
the units that are used and may be different. We recommend that you use
the PAScal software tool to calculate the safety function's SIL/PL values.

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 18
Supplementary data
CAUTION!
It is essential to consider the relay's service life graphs. The relay outputs'
safety-related characteristic data is only valid if the values in the service life
graphs are met.
The PFH value depends on the switch frequency and the load of the relay output.
If the service life graphs are not accessible, the stated PFH value can be used irrespective
of the switch frequency and the load, as the PFH value already considers the relay's B10d
value as well as the failure rates of the other components.
Service life graph
The service life graphs indicate the number of cycles from which failures due to wear must
be expected. The wear is mainly caused by the electrical load; the mechanical load is negli-
gible.
Number of cycles x 1000
Switching current (A)
Example
}Inductive load: 0.2 A
}Utilisation category: AC15
}Contact service life: 4 000 000 cycles
Provided the application to be implemented requires fewer than 4 000 000 cycles, the PFH
value (see Technical details) can be used in the calculation.
To increase the service life, sufficient spark suppression must be provided on all output
contacts. With capacitive loads, any power surges that occur must be noted. With DC con-
tactors, use flywheel diodes for spark suppression.

P2HZ X1.10P
Operating Manual P2HZ X1.10P
20817-EN-07 | 19
Order reference
Product type Features Terminals Order no.
P2HZ X1.10P C 24 V DC Spring-loaded terminals 787341
P2HZ X1.10P 24 V DC Screw terminals 777341
EC declaration of conformity
This product/these products meet the requirements of the directive 2006/42/EC for ma-
chinery of the European Parliament and of the Council. The complete EC Declaration of
Conformity is available on the Internet at www.pilz.com/support/downloads.
Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost-
fildern, Germany

The Best of
German
Engineering
Partner of:
Support
Technical support is available from Pilz round the clock.
Americas
Brazil
+55 11 97569-2804
Canada
+1 888 315 7459
Mexico
+52 55 5572 1300
USA (toll-free)
+1 877-PILZUSA (745-9872)
Asia
China
+86 21 60880878-216
Japan
+81 45 471-2281
South Korea
+82 31 778 3300
Australia
+61 3 95600621
Europe
Austria
+43 1 7986263-0
Belgium, Luxembourg
+32 9 3217570
France
+33 3 88104003
Germany
+49 711 3409-444
Ireland
+353 21 4804983
Italy, Malta
+39 0362 1826711
Scandinavia
+45 74436332
Spain
+34 938497433
Switzerland
+41 62 88979-32
The Netherlands
+31 347 320477
Turkey
+90 216 5775552
United Kingdom
+44 1536 462203
You can reach our
international hotline on:
+49 711 3409-444
suppor[email protected]
Pilz develops environmentally-friendly products using
ecological materials and energy-saving technologies.
Oces and production facilities are ecologically designed,
environmentally-aware and energy-saving. So Pilz oers
sustainability, plus the security of using energy-ecient
products and environmentally-friendly solutions.
We are represented internationally. Please refer to our homepage www.pilz.com
for further details or contact our headquarters.
Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected], Internet: www.pilz.com
CECE®, CHRE®, CMSE®, InduraNET p®, Leansafe®, Master of Safety®, Master of Security®, PAS4000®, PAScal®, PASconfig®, Pilz®, PIT®, PLID®, PMCprimo®, PMCprotego®, PMCtendo®,
PMD®, PMI®, PNOZ®, PRBT®, PRCM®, Primo®, PRTM®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, THE SPIRIT OF SAFETY®are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication
and the scope of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information. Please contact our Technical Support
if you have any questions.
1800XXXX-en-0X, 2019-05 Printed in Germany
© Pilz GmbH & Co. KG, 2019
Back cover
20817-EN-07, 2020-10 Printed in Germany
© Pilz GmbH & Co. KG, 2019
Other manuals for P2HZ X1.10P
1
Table of contents
Other Pilz Relay manuals