Pilz PZE 9P User manual

PZE 9P
Operating Manual-1003288-EN-13
}Safety relays

Preface
This document is the original document.
All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made
for the user's internal purposes. Suggestions and comments for improving this documenta-
tion will be gratefully received.
Source code from third-party manufacturers or open source software has been used for
some components. The relevant licence information is available on the Internet on the Pilz
homepage.
Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®,
SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks
of Pilz GmbH & Co. KG in some countries.
SD means Secure Digital

Contents
Operating Manual PZE 9P
1003288-EN-13 | 3
Introduction ............................................................................................................................4
Validity of documentation.......................................................................................................... 4
Using the documentation .......................................................................................................... 4
Definition of symbols................................................................................................................. 4
Safety ...................................................................................................................................... 5
Intended use ............................................................................................................................. 5
Safety regulations ..................................................................................................................... 5
Safety assessment ................................................................................................................... 5
Use of qualified personnel ........................................................................................................ 6
Warranty and liability ................................................................................................................ 6
Disposal .................................................................................................................................... 6
For your safety.......................................................................................................................... 6
Unit features ...........................................................................................................................7
Safety features ....................................................................................................................... 7
Block diagram/terminal configuration ................................................................................. 7
Type: 24 V AC/DC .................................................................................................................... 7
Type: 24 - 240 V AC/DC ........................................................................................................... 8
Function description ............................................................................................................. 8
Installation ..............................................................................................................................8
Wiring ......................................................................................................................................9
Preparing for operation ......................................................................................................... 9
Operation ................................................................................................................................10
Status indicators ....................................................................................................................... 11
Faults – Interference .............................................................................................................. 11
Dimensions in mm .................................................................................................................11
Technical details ....................................................................................................................12
Safety characteristic data ......................................................................................................... 23
Supplementary data ..............................................................................................................24
Service life graph ...................................................................................................................... 24
Remove plug-in terminals ..................................................................................................... 25
Order reference ......................................................................................................................25
EC declaration of conformity ................................................................................................ 25

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 4
Introduction
Validity of documentation
This documentation is valid for the product PZE 9P. It is valid until new documentation is
published.
This operating manual explains the function and operation, describes the installation and
provides guidelines on how to connect the product.
Using the documentation
This document is intended for instruction. Only install and commission the product if you
have read and understood this document. The document should be retained for future ref-
erence.
Definition of symbols
Information that is particularly important is identified as follows:
DANGER!
This warning must be heeded! It warns of a hazardous situation that poses
an immediate threat of serious injury and death and indicates preventive
measures that can be taken.
WARNING!
This warning must be heeded! It warns of a hazardous situation that could
lead to serious injury and death and indicates preventive measures that can
be taken.
CAUTION!
This refers to a hazard that can lead to a less serious or minor injury plus
material damage, and also provides information on preventive measures
that can be taken.
NOTICE
This describes a situation in which the product or devices could be dam-
aged and also provides information on preventive measures that can be
taken. It also highlights areas within the text that are of particular import-
ance.

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 5
INFORMATION
This gives advice on applications and provides information on special fea-
tures.
Safety
Intended use
The contact expansion module PZE 9P meets the requirements of EN 60947-5-1 and EN
60204- 1. It is an expansion module for increasing the number of contacts available on a
base unit. Base units are all
}Safety relays with feedback loop
}programmable safety systems with feedback loop
The max. achievable safety level depends on the base unit. The expansion module may not
exceed this. The safety-related characteristic values stated under safety-related character-
istic data [ 23] can only be achieved if the base unit also exhibits these safety charac-
teristic values.
The following is deemed improper use in particular
}Any component, technical or electrical modification to the product,
}Use of the product outside the areas described in this manual,
}Use of the product outside the technical details (see Technical details [ 12]).
NOTICE
EMC-compliant electrical installation
The product is designed for use in an industrial environment. The product
may cause interference if installed in other environments. If installed in other
environments, measures should be taken to comply with the applicable
standards and directives for the respective installation site with regard to in-
terference.
Safety regulations
Safety assessment
Before using a device, a safety assessment in accordance with the Machinery Directive is
required.
The product as an individual component fulfils the functional safety requirements in accord-
ance with EN ISO 13849 and EN 62061. However, this does not guarantee the functional
safety of the overall plant/machine. To achieve the relevant safety level of the overall plant/
machine’s required safety functions, each safety function needs to be considered separ-
ately.

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 6
Use of qualified personnel
The products may only be assembled, installed, programmed, commissioned, operated,
maintained and decommissioned by persons who are competent to do so.
A competent person is a qualified and knowledgeable person who, because of their train-
ing, experience and current professional activity, has the specialist knowledge required. To
be able to inspect, assess and operate devices, systems and machines, the person has to
be informed of the state of the art and the applicable national, European and international
laws, directives and standards.
It is the company’s responsibility only to employ personnel who
}Are familiar with the basic regulations concerning health and safety / accident prevention,
}Have read and understood the information provided in the section entitled Safety
}Have a good knowledge of the generic and specialist standards applicable to the specific
application.
Warranty and liability
All claims to warranty and liability will be rendered invalid if
}The product was used contrary to the purpose for which it is intended,
}Damage can be attributed to not having followed the guidelines in the manual,
}Operating personnel are not suitably qualified,
}Any type of modification has been made (e.g. exchanging components on the PCB
boards, soldering work etc.).
Disposal
}In safety-related applications, please comply with the mission time TM in the safety-related
characteristic data.
}When decommissioning, please comply with local regulations regarding the disposal of
electronic devices (e.g. Electrical and Electronic Equipment Act).
For your safety
The unit meets all the necessary conditions for safe operation. However, please note the
following:
}Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120
VDC) are present on the unit, connected control elements and sensors must have a rated
insulation voltage of at least 250 V.

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 7
Unit features
}Positive-guided relay outputs:
– 8 safety contacts (N/O), instantaneous
– 1 auxiliary contact (N/C), instantaneous
}LED display for:
– Supply voltage
– Switch status of the safety contacts
}Connection for feedback loop
}Operation: Single or dual-channel
}Plug-in connection terminals (either spring-loaded terminal or screw terminal)
}See order reference for unit types
Safety features
The unit meets the following safety requirements:
}The contact expansion module expands an existing circuit. As the output relays are mon-
itored via the base unit's feedback loop, the safety functions on the existing circuit are
transferred to the contact expandsion module.
}The safety function remains effective in the case of a component failure.
}Earth fault in the feedback loop:
Detected, depending on the base unit that is used.
}Earth fault in the input circuit:
The output relays de-energise and the safety contacts open.
Block diagram/terminal configuration
Type: 24 V AC/DC
}UB: 24 VAC/DC; Order no. 777140, 787140
*Safe separation from non-marked area, except for safety contact 13-14, in accordance
with EN 60947-1, 6 kV, basic insulation between all safety contacts.

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 8
Type: 24 - 240 V AC/DC
}UB: 24 - 240 VAC/DC, 24 VAC/DC; Order no. 777148, 787148
*Safe separation from non-marked area, except for safety contact 13-14, in accordance
with EN 60947-1, 6 kV, basic insulation between all safety contacts.
Function description
The contact expansion module PZE 9P is an add-on device without delay-on de-energisa-
tion. It is used to expand a safety circuit. The contact expansion module is driven by a base
unit (e. g. emergency stop relay). When operating voltage is supplied the "POWER" LED
will light.
}Functional procedure once the input circuit is closed (e.g. safety contacts on the base unit
are closed):
– Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 and 83-84 close,
auxiliary contact 91-92 opens.
– The LEDs "CH.1" and "CH.2" are lit.
}Functional procedure once the input circuit is opened (e.g. safety contacts on the base
unit are opened):
– Safety contacts 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74 and 83-84 are
opened redundantly, auxiliary contact 91-92 is closed.
– The LEDs "CH.1" and "CH.2" go out.
Installation
}The unit should be installed in a control cabinet with a protection type of at least IP54.
}Use the notch on the rear of the unit to attach it to a DIN rail (35 mm).
}When installed vertically: Secure the unit by using a fixing element (e.g. retaining bracket
or end angle).

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 9
Wiring
Please note:
}Information given in the "Technical details [ 12]" must be followed.
}Outputs 13-14, 23-24, 33-34, 43-44, 53-54, 63-64, 73-74, 83-84 are safety contacts; out-
put 91-92 is an auxiliary contact (e.g. for display).
}Do not use auxiliary contact 91-92 for safety circuits!
}Do not connect undesignated terminals.
}To prevent contact welding, a fuse should be connected before the output contacts (see
Technical details [ 12]).
}Calculation of the max. cable length lmax in the input circuit:
Rlmax
Rl / km
Imax =
Rlmax = max. overall cable resistance (see Technical details [ 12])
Rl/km = cable resistance/km
}Use copper wiring with a temperature stability of 60/75 °C.
}To prevent EMC interferences (particularly common-mode interferences) the measures
described in EN60204-1 must be executed. This includes the separate routing of cables
of the control circuits (input, start and feedback loop) from other cables for energy trans-
mission or the shielding of cables, for example.
}Adequate protection must be provided on all output contacts with capacitive and inductive
loads.
}Do not switch low currents using contacts that have been used previously with high cur-
rents.
}777140, 787140 units or 777148, 787148 units, when the supply voltage is connected via
B1 and B2: The power supply must meet the regulations for extra low voltages with pro-
tective electrical separation (SELV, PELV).
Preparing for operation
Supply voltage 24 - 240 V AC/DC 24 VAC/DC
Order no.: 777148, 787148
A1
A2
L1
N
FE
B1 L1/L+
N/L-
B2
Order no.: 777140, 787140

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 10
Input circuit Single-channel Dual-channel
without detection of shorts
across contacts
Base unit: Safety relay PNOZ X
Driven via safety contacts
K1
K2
U1
Y4
Y3
PZE
U2
K1
K2
U1
Y4
Y3
PZE
U2
with detection of shorts across
contacts
Base unit: Safety relay PNOZ X
Driven via safety contacts
K1
K2
U1
Y4
Y3
PZE
U2
without detection of shorts
across contacts
Base unit: Safety system or
PNOZmulti
Driven via safe semiconductor
outputs (24 VDC)
Feedback loop Base unit: Safety relay PNOZ X Base unit: Safety system or
PNOZmulti
Y1, Y2 and Input are inputs on
the base unit; they evaluate the
feedback loop
Operation
When the relay outputs are switched on, the mechanical contact on the relay cannot be
tested automatically. Depending on the operational environment, measures to detect the
non-opening of switching elements may be required under some circumstances.
When the product is used in accordance with the European Machinery Directive, a check
must be carried out to ensure that the safety contacts on the relay outputs open correctly.
Open the safety contacts of the contact expansion module (switch off outputs of the base
unit) and start the base unit again so that the internal diagnostics can check that the safety
contacts open correctly
}for SIL CL 3/PL e at least 1x per month
}for SIL CL 2/PL d at least 1x per year

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 11
NOTICE
The safety function should be checked after initial commissioning and each
time the plant/machine is changed. The safety functions may only be
checked by qualified personnel.
Status indicators
LEDs indicate the status and errors during operation:
LED on
POWER
Supply voltage is present.
CH.1
Safety contacts of channel 1 are closed.
CH.2
Safety contacts of channel 2 are closed.
Faults – Interference
By closing or interrupting the input circuit you can check whether the unit switches on or off
correctly.
For safety reasons, the unit cannot be started if the following faults are present:
}Contact malfunction: As the contact block is connected to a base unit,
reactivation will not be possible if the contacts have welded after the input circuit has
opened.
}Open circuit, short circuit or earth fault ( e.g. in the input circuit)
Dimensions in mm
75 (2.95")
121 (4.76")
87 (3.42")
90
(3.54")

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 12
Technical details
Order no. 777140 – 787140
See below for more order numbers
General 777140 787140
Certifications
CCC, CE, EAC (Eurasian), TÜV,
cULus Listed
CCC, CE, EAC (Eurasian), TÜV,
cULus Listed
Electrical data 777140 787140
Supply voltage
Voltage 24 V 24 V
Kind AC/DC AC/DC
Voltage tolerance -15 %/+10 % -15 %/+10 %
Output of external power supply
(AC) 9,5 VA 9,5 VA
Output of external power supply
(DC) 3,5 W 3,5 W
Frequency range AC 50 - 60 Hz 50 - 60 Hz
Residual ripple DC 160 % 160 %
Duty cycle 100 % 100 %
Inputs 777140 787140
Number 2 2
Voltage at
Input circuit DC 24 V 24 V
Current at
Input circuit DC 40 mA 40 mA
Max. overall cable resistance Rl-
max
Single-channel at UB DC 50 Ohm 50 Ohm
Single-channel at UB AC 80 Ohm 80 Ohm
Dual-channel without detection
of shorts across contacts at UB
DC 100 Ohm 100 Ohm
Dual-channel without detection
of shorts across contacts at UB
AC 160 Ohm 160 Ohm
Dual-channel with detection of
shorts across contacts at UB DC 5 Ohm 5 Ohm
Dual-channel with detection of
shorts across contacts at UB AC 10 Ohm 10 Ohm
Relay outputs 777140 787140
Number of output contacts
Safety contacts (N/O), instant-
aneous 8 8
Auxiliary contacts (N/C) 1 1
Max. short circuit current IK 1 kA 1 kA

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 13
Relay outputs 777140 787140
Utilisation category
In accordance with the standard EN 60947-4-1 EN 60947-4-1
Utilisation category of safety con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 2000 VA 2000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 200 W 200 W
Utilisation category of auxiliary con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 500 VA 500 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 50 W 50 W
Utilisation category
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Utilisation category of safety con-
tacts
AC15 at 230 V 230 V
Max. current 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 7 A 7 A
Utilisation category of auxiliary con-
tacts
AC15 at 230 V 230 V
Max. current 2 A 2 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 2 A 2 A
Utilisation category in accordance
with UL
Voltage 240 V AC G. P. 240 V AC G. P.
With current 8 A 8 A
Voltage 24 V DC G. P. Resistive 24 V DC G. P. Resistive
With current 5 A 5 A
Pilot Duty B300, R300 B300, R300

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 14
Relay outputs 777140 787140
External contact fuse protection,
safety contacts
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Max. melting integral 240 A²s 240 A²s
Blow-out fuse, quick 10 A 10 A
Blow-out fuse, slow 6 A 6 A
Blow-out fuse, gG 10 A 10 A
Circuit breaker 24V AC/DC,
characteristic B/C 6 A 6 A
External contact fuse protection,
auxiliary contacts
Max. melting integral 240 A²s 240 A²s
Blow-out fuse, quick 4 A 4 A
Blow-out fuse, slow 2 A 2 A
Blow-out fuse, gG 4 A 4 A
Circuit breaker 24 V AC/DC,
characteristic B/C 2 A 2 A
Contact material AgSnO2 + 0,2 µm Au AgSnO2 + 0,2 µm Au
Conventional thermal current
while loading several contacts
777140 787140
Ith per contact at UB AC;
AC1:240V,DC1:24V
Conv. therm. current with 1 con-
tact 8 A 8 A
Conv. therm. current with 2 con-
tacts 8 A 8 A
Conv. therm. current with 3 con-
tacts 8 A 8 A
Conv. therm. current with 4 con-
tacts 7,1 A 7,1 A
Conv. therm. current with 5 con-
tacts 6,3 A 6,3 A
Conv. therm. current with 6 con-
tacts 5,8 A 5,8 A
Conv. therm. current with 7 con-
tacts 5,4 A 5,4 A
Conv. therm. current with 8 con-
tacts 5 A 5 A

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 15
Conventional thermal current
while loading several contacts
777140 787140
Ith per contact at UB DC;
AC1:240V,DC1:24V
Conv. therm. current with 1 con-
tact 8 A 8 A
Conv. therm. current with 2 con-
tacts 8 A 8 A
Conv. therm. current with 3 con-
tacts 8 A 8 A
Conv. therm. current with 4 con-
tacts 7,1 A 7,1 A
Conv. therm. current with 5 con-
tacts 6,3 A 6,3 A
Conv. therm. current with 6 con-
tacts 5,8 A 5,8 A
Conv. therm. current with 7 con-
tacts 5,4 A 5,4 A
Conv. therm. current with 8 con-
tacts 5 A 5 A
Times 777140 787140
Switch-on delay
With automatic start typ. 30 ms 30 ms
With automatic start max. 40 ms 40 ms
With automatic start after power
on typ. 30 ms 30 ms
With automatic start after power
on max. 40 ms 40 ms
Delay-on de-energisation
With E-STOP typ. 20 ms 20 ms
With E-STOP max. 30 ms 30 ms
With power failure typ. 110 ms 110 ms
With power failure max. 200 ms 200 ms
Supply interruption before de-ener-
gisation in the input circuit 10 ms 10 ms
Supply interruption before de-ener-
gisation 20 ms 20 ms
Environmental data 777140 787140
Climatic suitability EN 60068-2-78 EN 60068-2-78
Ambient temperature
Temperature range -10 - 55 °C -10 - 55 °C
Storage temperature
Temperature range -40 - 85 °C -40 - 85 °C
Climatic suitability
Humidity 93 % r. h. at 40 °C 93 % r. h. at 40 °C
Condensation during operation Not permitted Not permitted
EMC EN 60947-5-1, EN 61000-6-2, EN
61326-3-1
EN 60947-5-1, EN 61000-6-2, EN
61326-3-1

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 16
Environmental data 777140 787140
Vibration
In accordance with the standard EN 60068-2-6 EN 60068-2-6
Frequency 10 - 55 Hz 10 - 55 Hz
Amplitude 0,35 mm 0,35 mm
Airgap creepage
In accordance with the standard EN 60947-1 EN 60947-1
Overvoltage category III III
Pollution degree 2 2
Rated insulation voltage 250 V 250 V
Rated impulse withstand voltage 6 kV 6 kV
Protection type
Housing IP40 IP40
Terminals IP20 IP20
Mounting area (e.g. control cab-
inet) IP54 IP54
Mechanical data 777140 787140
Mounting position Any Any
Mechanical life 10,000,000 cycles 10,000,000 cycles
Material
Bottom PPO UL 94 V0 PPO UL 94 V0
Front ABS UL 94 V0 ABS UL 94 V0
Top PPO UL 94 V0 PPO UL 94 V0
Connection type Screw terminal Spring-loaded terminal
Mounting type plug-in plug-in
Conductor cross section with screw
terminals
1 core flexible 0,25 - 2,5 mm², 24 - 12 AWG –
2 core with the same cross sec-
tion, flexible with crimp connect-
ors, no plastic sleeve 0,25 - 1 mm², 24 - 16 AWG –
2 core with the same cross sec-
tion, flexible without crimp con-
nectors or with TWIN crimp con-
nectors 0,2 - 1,5 mm², 24 - 16 AWG –
Torque setting with screw terminals 0,5 Nm –
Stripping length with screw termin-
als 8 mm –
Conductor cross section with
spring-loaded terminals: Flexible
with/without crimp connector – 0,2 - 1,5 mm², 24 - 16 AWG
Spring-loaded terminals: Terminal
points per connection – 2
Stripping length with spring-loaded
terminals – 8 mm

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 17
Mechanical data 777140 787140
Dimensions
Height 87 mm 87 mm
Width 90 mm 90 mm
Depth 121 mm 121 mm
Weight 430 g 430 g
Where standards are undated, the 2020-07 latest editions shall apply.
Order no. 777148 – 787148
General 777148 787148
Certifications
CCC, CE, EAC (Eurasian), TÜV,
cULus Listed
CCC, CE, EAC (Eurasian), TÜV,
cULus Listed
Electrical data 777148 787148
Supply voltage
Voltage 24 - 240 V 24 - 240 V
Kind AC/DC AC/DC
Voltage tolerance -15 %/+10 % -15 %/+10 %
Output of external power supply
(AC) 9,5 VA 9,5 VA
Output of external power supply
(DC) 6 W 6 W
Frequency range AC 50 - 60 Hz 50 - 60 Hz
Residual ripple DC 160 % 160 %
Supply voltage
Voltage 24 V 24 V
Kind AC/DC AC/DC
Voltage tolerance -15 %/+10 % -15 %/+10 %
Output of external power supply
(AC) 9,5 VA 9,5 VA
Output of external power supply
(DC) 3,5 W 3,5 W
Frequency range AC 50 - 60 Hz 50 - 60 Hz
Residual ripple DC 160 % 160 %
Duty cycle 100 % 100 %
Inputs 777148 787148
Number 2 2
Voltage at
Input circuit DC 24 V 24 V
Current at
Input circuit DC 40 mA 40 mA

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 18
Inputs 777148 787148
Max. overall cable resistance Rl-
max
Single-channel at UB DC 50 Ohm 50 Ohm
Single-channel at UB AC 80 Ohm 80 Ohm
Dual-channel without detection
of shorts across contacts at UB
DC 100 Ohm 100 Ohm
Dual-channel without detection
of shorts across contacts at UB
AC 160 Ohm 160 Ohm
Dual-channel with detection of
shorts across contacts at UB DC 3 Ohm 3 Ohm
Dual-channel with detection of
shorts across contacts at UB AC 8 Ohm 8 Ohm
Relay outputs 777148 787148
Number of output contacts
Safety contacts (N/O), instant-
aneous 8 8
Auxiliary contacts (N/C) 1 1
Max. short circuit current IK 1 kA 1 kA
Utilisation category
In accordance with the standard EN 60947-4-1 EN 60947-4-1
Utilisation category of safety con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 2000 VA 2000 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 8 A 8 A
Max. power 200 W 200 W
Utilisation category of auxiliary con-
tacts
AC1 at 240 V 240 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 500 VA 500 VA
DC1 at 24 V 24 V
Min. current 0,01 A 0,01 A
Max. current 2 A 2 A
Max. power 50 W 50 W
Utilisation category
In accordance with the standard EN 60947-5-1 EN 60947-5-1

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 19
Relay outputs 777148 787148
Utilisation category of safety con-
tacts
AC15 at 230 V 230 V
Max. current 5 A 5 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 7 A 7 A
Utilisation category of auxiliary con-
tacts
AC15 at 230 V 230 V
Max. current 2 A 2 A
DC13 (6 cycles/min) at 24 V 24 V
Max. current 2 A 2 A
Utilisation category in accordance
with UL
Voltage 240 V AC G. P. 240 V AC G. P.
With current 8 A 8 A
Voltage 24 V DC G. P. Resistive 24 V DC G. P. Resistive
With current 5 A 5 A
Pilot Duty B300, R300 B300, R300
External contact fuse protection,
safety contacts
In accordance with the standard EN 60947-5-1 EN 60947-5-1
Max. melting integral 240 A²s 240 A²s
Blow-out fuse, quick 10 A 10 A
Blow-out fuse, slow 6 A 6 A
Blow-out fuse, gG 10 A 10 A
Circuit breaker 24V AC/DC,
characteristic B/C 6 A 6 A
External contact fuse protection,
auxiliary contacts
Max. melting integral 240 A²s 240 A²s
Blow-out fuse, quick 4 A 4 A
Blow-out fuse, slow 2 A 2 A
Blow-out fuse, gG 4 A 4 A
Circuit breaker 24 V AC/DC,
characteristic B/C 2 A 2 A
Contact material AgSnO2 + 0,2 µm Au AgSnO2 + 0,2 µm Au

PZE 9P
Operating Manual PZE 9P
1003288-EN-13 | 20
Conventional thermal current
while loading several contacts
777148 787148
Ith per contact at UB AC;
AC1:240V,DC1:24V
Conv. therm. current with 1 con-
tact 8 A 8 A
Conv. therm. current with 2 con-
tacts 8 A 8 A
Conv. therm. current with 3 con-
tacts 8 A 8 A
Conv. therm. current with 4 con-
tacts 7,1 A 7,1 A
Conv. therm. current with 5 con-
tacts 6,3 A 6,3 A
Conv. therm. current with 6 con-
tacts 5,8 A 5,8 A
Conv. therm. current with 7 con-
tacts 5,4 A 5,4 A
Conv. therm. current with 8 con-
tacts 5 A 5 A
Ith per contact at UB DC;
AC1:240V,DC1:24V
Conv. therm. current with 1 con-
tact 8 A 8 A
Conv. therm. current with 2 con-
tacts 8 A 8 A
Conv. therm. current with 3 con-
tacts 8 A 8 A
Conv. therm. current with 4 con-
tacts 7,1 A 7,1 A
Conv. therm. current with 5 con-
tacts 6,3 A 6,3 A
Conv. therm. current with 6 con-
tacts 5,8 A 5,8 A
Conv. therm. current with 7 con-
tacts 5,4 A 5,4 A
Conv. therm. current with 8 con-
tacts 5 A 5 A
Times 777148 787148
Switch-on delay
With automatic start typ. 30 ms 30 ms
With automatic start max. 40 ms 40 ms
With automatic start after power
on typ. 300 ms 300 ms
With automatic start after power
on max. 350 ms 350 ms
Other manuals for PZE 9P
1
This manual suits for next models
4
Table of contents
Other Pilz Relay manuals

Pilz
Pilz PNOZ e6.1p User manual

Pilz
Pilz PNOZ X3.2 User manual

Pilz
Pilz S1MN User manual

Pilz
Pilz PST 4 User manual

Pilz
Pilz myPNOZ User manual

Pilz
Pilz PZW Series User manual

Pilz
Pilz PNOZ XV3.3P User manual

Pilz
Pilz PNOZSIGMA Series User manual

Pilz
Pilz PZE X4VP User manual

Pilz
Pilz PSEN ma1.3p-20 User manual