6 Power failure (2)
Identification of
defective Assy
JACK Assy
HPJK Assy
HPLC Assy
Disconnect the cables from each Assy in
order to confirm which Assy’s power is
abnormal.
If the voltage returns to a normal level when the
cables from either the JACK Assy or HPJK Assy
are disconnected, the internal circuits of the
corresponding Assy may be defective. If the
voltage returns to a normal level when the cables
from the HPLC Assy are disconnected, either
the internal circuits of the HPLC Assy or the
circuit to which power is supplied from
V+5_HP_OUT inside the IFPWAssy may be
defective.
4.1 OVERALL
WIRTING DIAGRAM
4.3 POWER BLOCK
DIAGRAM
7 Power failure (3)
Identification of
defective power
system
FAULT_DET
IFPWAssy
Deactivate the voltage monitoring circuit
then check the section with improper
voltage.
The voltage monitoring circuit can be deactivated by
removing R337 (0 Ω) on the FAULT_DET.
See the notes in “5.3 VOLTAGE MONITORING”
before proceeding to further diagnostics.
To identify the section with improper voltage, check
the voltage at each point on the IFPWAssy.
4.3 POWER BLOCK
DIAGRAM
5.3 VOLTAGE
MONITORING
10.12 VOLATGES
10.13 WAVEFORMS
1256789a
cd1238
[1-2] Failure in the microcomputer system
1 Power failure in
the MAINUCOM
CDJ1 Assy Check the power terminal of the
MAINUCOM (IC1002).
Check the power and voltage are normal.
Check the power line and the parts, such as coils
(beads), resistors, and capacitors.
If no problem was found with the parts, power line,
and conduction between the power supply and
GND, the MAINUCOM (IC1002) may be defective.
10.12 VOLATGES
2
2 MAINUCOM
Reset circuit
error
CDJ1 Assy Check the Reset terminal (pin 12) of the
MAINUCOM (IC1002).
In normal operation the voltage of the Reset
terminal (Pin 17) is high.
If it is low, check if the voltage at V+3R3_UCOM is
2.7 Vor less.
Check the reset line, resistors, capacitors, and
the Reset IC (IC1001).
10.12 VOLATGES
10.13 WAVEFORMS
2
3 MAINUCOM
X'tal error
CDJ1 Assy Check the oscillation waveforms of the
X'tal (X1001).
In normalcy, oscillate it at 24 MHz. If the oscillation
waveforms are abnormal, check the resistor on the
oscillation-signal line, the capacitor, and X'tal
(X1001). If nothing is wrong with these parts, the
MAINUCOM (IC1002) may be defective.
10.13 WAVEFORMS
I
4 MAINUCOM
startup error
CDJ1 Assy After startup, check the lighting statuses of
the LEDs.
(For example, although some of the LEDs
light properly, the unit is not started up
properly.)
Refer to “6.6 ERRROR DISPLAY”.
If there is no corresponding error indication,
reload the program via USB.
(8.3 HOWTO FIRMWARE UPDATE)
If the normal status is not recovered after all
above steps are performed, the MAINUCOM
(IC1002) may be defective.
6.6 ERROR DISPLAY
8.3 HOWTO
FIRMWARE UPDATE
5 Power failure in
the USB
Controller
IFPWAssy Check if a voltage error was detected.
Check the power terminal of the USB
Controller (IC102).
If the detected voltage error is confirmed, check
conduction between the power supply and GND.
Check the power line and the parts, such as coils
(beads), resistors, and capacitors.
If no problem was found with the parts, power line,
and conduction between the power supply and GND,
the USB Controller (IC102) may be defective.
5.3 VOLTAGE
MONITORING
10.13 WAVEFORMS
578
4 Power failure in
the MAINUCOM
on the IFPW
Assy
IFPWAssy Set the POWER switch to ON.
If V+3R3_UCOM is abnormal
(2.7 Vor less)
Disconnect the FFC connected between the
IFPWAssy and CDJ 1 Assy. If the voltage of the
V+3R3_UCOM returns to a normal level, the
regulator (IC304) or its peripheral circuits may
be defective.
4.3 POWER BLOCK
DIAGRAM
10.12 VOLATGES
2
5 Power failure in
the MAINUCOM
CDJ1 Assy
CDJ2 Assy
JOG1, JOG2 Assy
TCH1, TCH2 Assy
Set the POWER switch to ON.
If V+3R3_UCOM is abnormal
(2.7 Vor less)
Disconnect the cables from the JOG1, JOG2,
TCH1, and TCH2 Assys. If the voltage at
V+3R3_UCOM returns to a normal level, the
internal circuits of the JOG1, JOG2, TCH1, or
TCH2 Assy may be defective. If the voltage does
not return to a normal level, the MAINUCOM
(IC1002) or its peripheral circuits and the circuits
to which power is supplied from the
V+3R3_UCOM may be defective.
4.3 POWER BLOCK
DIAGRAM
10.12 VOLATGES
2
No. Cause Diagnostics Point Item to be Checked Corrective Action Reference
No. Cause Diagnostics Point Item to be Checked Corrective Action Reference