Flypod®
INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE
PERSONNEL ONLY.
Flypod®Once correctly positioned on a horizontal surface, fit
the glupac®glueboard in position as described in the
glueboard replacement section of this document. Flypod®
has a plug fitted to the mains lead and once installed in
position, should be plugged into the nearest mains outlet.
CLEANING
CLEANING SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly when
the glueboard is replaced. Once the glueboard is removed,
the unit should be thoroughly wiped down with a damp
cloth, removing any build up of dirt. Ensure the unit is
completely dry before reconnecting it to the power supply.
Decorative Glueboard Insect Control
Glueboard Installation
Please read these instructions carefully and store in a safe
place for future reference.
FLYPOD®
As part of the Insect-O-Cutor®brand of insect control
products, Flypod®is an easy to service and highly effective
decorative insect control unit for use within front of house
applications. Flypod®utilises a highly effective UV tube and
is designed for use with a high specification glupac®
glueboard. Patented glueboard technology ensures the
user doesn’t come into contact with caught flies.
CONTENTS OF PACKAGE
- 1 x Flypod®flykiller
- 1 x glupac®pheromone impregnated glueboard
- 1 x Compact 18W tube (fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
Flypod®utilises high powered ultra violet tubes to attract
flying insects and retains the caught insects on a pheromone
impregnated glueboard for inspection or hygienic disposal.
WARNING
Flypod®is not to be used by children or persons with reduced
physical, sensory or mental capabilities, or lack of experience
and knowledge, unless they have been given supervision or
instruction.
Children should be supervised to ensure they do not play
with the appliance.
If the mains cable is damaged it must be replaced by a
specialist mains cable available from P+L Systems Ltd or your
supplier.
Not suitable for applications where potentially explosive
environments may exist.
POSITIONING AND GUIDANCE FOR USE
THIS UNIT IS FOR INDOOR USE ONLY.
Flypod®should ideally be positioned in the darkest place
within the area to be protected. Do not position the unit
close to windows, skylights or other sources of light, or where
it may be obscured by furniture, doors or other obstacles.
Ideally, Flypod®should be visible from every part of the area
to be protected.
Flypod®should ideally be in operation for 24 hours a day,
ensuring your premises are kept free of flying insects. Insects
are most attracted to Flypod®at night when there is no
competition from daylight or other light sources.
GUARANTEE
Flypod®has a two year guarantee and if maintained as
recommended in these instructions should continue to work
for many years.* Use of non-approved consumables may
invalidate the guarantee. Ensure genuine glupac®
glueboards are used in conjunction with this product.
*Excludes tube, glueboard and starter. Does not cover breakdown due to misuse, incorrect
operation or use in an incorrect application.
Glueboard ReplacementTube Replacement
GLUEBOARD REPLACEMENT
GLUEBOARD REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac®glueboard. Use of
non-approved glueboards may invalidate your guarantee.
To replace the glueboard…
1. Position Flypod®so the back is facing you.
2. Using one hand to support the unit, use your thumb and forefinger of your other hand
to gently pull the used glueboard out through the slot in the back of the unit.
3. Once free from the unit, dispose of the used glueboard hygienically.
4. Remove the protective release paper from the new glupac®glueboard.
5. Slowly slide the new glueboard into position along the two runners with
the adhesive side facing the tube.
Always ensure the selected genuine glupac®glueboards are compatible with your unit, available
from your pest control operator or P+L Systems Ltd.
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING THAT
THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of Flypod®in catching flying insects, the UV tube should be replaced
annually. After twelve months the phosphor coating that emits the correct wavelength of UV light
has burnt away and the UV output is diminished substantially.
To replace the UV tube...
1. Pull the tube gently from the tube holder until it un-clips.
2. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
STARTER REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER ENSURING
THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The starter provides an extra spark to initially light the UV tube. Starters wear out and should be
replaced at the same intervals as the UV tube.
To replace the starter…
1. Remove the glueboard from the units described above.
2. Rotate the starter anti-clockwise.
3. Pull the starter free from the unit.
Unit Flypod
Voltage 230V - 50Hz
Dimensions (mm) 200 x 310 x 170
Coverage 30 Sq. Meters
Weight 1.5kg
Light Output 18W
Tubes 1 x TPX18
Starter 1 x I154
Glueboard (x6) INF252 (White)
SPECIFICATION / REPLACEMENT PARTS
Starter Replacement
R4 03/14
C2014
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
WEEE Compliance No. WEE/GF0661QR

Other PL Systems Insect Control Equipment manuals

PL Systems Flytrap Professional Series User manual

PL Systems

PL Systems Flytrap Professional Series User manual

PL Systems Flypod User manual

PL Systems

PL Systems Flypod User manual

PL Systems PlusLight 30 User manual

PL Systems

PL Systems PlusLight 30 User manual

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems Luralite Plus User manual

PL Systems

PL Systems Luralite Plus User manual

PL Systems EXOCUTER EX6 User manual

PL Systems

PL Systems EXOCUTER EX6 User manual

PL Systems Satalite 18 User manual

PL Systems

PL Systems Satalite 18 User manual

PL Systems PlusZap PZ16 User manual

PL Systems

PL Systems PlusZap PZ16 User manual

PL Systems FTC30 User manual

PL Systems

PL Systems FTC30 User manual

Popular Insect Control Equipment manuals by other brands

DynaTrap DT1750 owner's manual

DynaTrap

DynaTrap DT1750 owner's manual

Gardigo 70031 instruction manual

Gardigo

Gardigo 70031 instruction manual

Luci Mushitora XIA user manual

Luci

Luci Mushitora XIA user manual

Curtis Dyna-Fog MAXI-PRO 145 manual

Curtis Dyna-Fog

Curtis Dyna-Fog MAXI-PRO 145 manual

Perel GIK37 user manual

Perel

Perel GIK37 user manual

Kogan Pestill PPFLYRPFANA user guide

Kogan

Kogan Pestill PPFLYRPFANA user guide

Coleman Mosquito Deleto 2200 Instructions for use

Coleman

Coleman Mosquito Deleto 2200 Instructions for use

Select Insect-O-Cutor SE22 instructions

Select

Select Insect-O-Cutor SE22 instructions

Biogents BG-Home instruction manual

Biogents

Biogents BG-Home instruction manual

Quest Engineering C0023 instructions

Quest Engineering

Quest Engineering C0023 instructions

Yardistry YM12834 installation instructions

Yardistry

Yardistry YM12834 installation instructions

VIROSMART VS-500 ULV user manual

VIROSMART

VIROSMART VS-500 ULV user manual

Gemmy BUBBLE FOGGER 20931 instructions

Gemmy

Gemmy BUBBLE FOGGER 20931 instructions

ThermaCell Tick control tubes quick start guide

ThermaCell

ThermaCell Tick control tubes quick start guide

Gardigo 70490 instruction manual

Gardigo

Gardigo 70490 instruction manual

Hendi 270158 user manual

Hendi

Hendi 270158 user manual

Kooper Flash 2192075 User instructions

Kooper

Kooper Flash 2192075 User instructions

Biogents BG-Home instruction manual

Biogents

Biogents BG-Home instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.