manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PL Systems
  6. •
  7. Insect Control Equipment
  8. •
  9. PL Systems Flytrap Professional Series User manual

PL Systems Flytrap Professional Series User manual

FTP30, 40 & 80
Please read these instructions carefully and store in a safe
place for future reference.
FLYTRAP PROFESSIONALTM
As part of the P+L brand of insect control products, Flytrap
ProfessionalTM is an effective and versatile professional flykiller
which utilises highly effective UV tubes and is designed for use
with a high specification glupac™glueboard. Three sizes of
unit are available, all of which can be white coated mild
steel or high grade stainless steel. Flytrap ProfessionalTM can
be mounted by seven different methods, making it the most
flexible professional flykiller on the market.
Contents of package
- 1 x Flytrap Professional flykiller
- 1 x glupac™ pheromone impregnated glueboard
- 1 x Mounting options sheet
- 2 x Screws wall plugs and suspension keyrings
- 1 x Mains cable
- 2 x High powered UV tubes (Fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED
INSECT CONTROL PRODUCTS
Flytrap ProfessionalTM utilises high powered ultra violet tubes to
attract flying insects and retains the caught insects on a
pheromone impregnated glueboard for inspection or
hygienic disposal.
POSITIONING
THIS UNIT IS FOR INDOOR USE ONLY.
Flytrap ProfessionalTM should ideally be fixed around two
meters above the ground, preferably in the darkest place
within the area to be protected and is supplied with a two
meter mains lead. Do not position the unit close to windows,
skylights or other sources of light, or where it may be
obscured by furniture, doors or other obstacles. Ideally,
Flytrap ProfessionalTM unit should be visible from every part of
the area to be protected.
INSTALLATION
PRIOR TO INSTALLATION, ENSURE THE POWER SUPPLY OF YOUR
MAINS OUTLET CORRESPONDS TO THAT MARKED ON THE
SPECIFICATION LABEL FOUND ON THE FLYKILLER.
Flytrap ProfessionalTM can be mounted in seven different ways
as shown in the seperate mounting options document. Once
installed in position, fit the glupac™ glueboard in position as
described in the glueboard replacement section of this
document. Use the removable mains lead and plug to
connect the Flytrap ProfessionalTM to an appropriate power
supply.
WARNING - THIS APPLIANCE MUST BE EARTHED
USING FLYTRAP PROFESSIONAL
Flytrap Professional should ideally be in operation for 24 hours
a day, ensuring your premises are kept free of flying insects.
Insects are most attracted to Flytrap Professional unit at night
when there is no competition from daylight or other light
sources.
CLEANING
ENSURE THAT THE FLYING INSECT KILLER IS DISCONNECTED
FROM THE MAINS BEFORE CLEANING
It is recommended that cleaning is carried out regularly when
the glueboard is replaced. Once the glueboard is removed,
the unit should be thoroughly wiped down with a damp
cloth, removing any build up of dirt. Ensure the unit is
completely dry before reconnecting it to the power supply.
GUARANTEE
Flytrap ProfessionalTM has a three year guarantee and if
maintained as recommended in these instructions should
continue to work for many years.* Use of non-approved
consumables may invalidate the guarantee. Ensure genuine
glupac™ glueboards are used in conjunction with this
product.
*Excludes tubes, glueboards and starters. Does not cover breakdown due to misuse,
incorrect operation or use in an incorrect application.
Professional Glueboard Insect Control
Tube ReplacementStarter Replacement
SPECIFICATION / REPLACEMENT PARTS
Unit FTP30
Voltage 230V ~ 50Hz
Dimensions(mm) 470 x 305 x 152
Coverage 80 Sq. Meters
Weight 4 Kg
Light Output 30W
Tubes 2 x I616
Starter 2 x I154
Glueboards (x6) INF196
Unit FTP40
Voltage 230V ~ 50Hz
Dimensions(mm) 610 x 305 x 152
Coverage 120 Sq. Meters
Weight 5 Kg
Light Output 40W
Tubes 2 x I618
Starter 2 x I154
Glueboards (x6) INF198
Unit FTP80
Voltage 230V ~ 50Hz
Dimensions(mm) 610 x 305 x 152
Coverage 240 Sq. Meters
Weight 5 Kg
Light Output 80W
Tubes 2 x I662
Starter 2 x I154
Glueboards (x6) INF198
GLUEBOARD REPLACEMENT
BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS
DISCONNECTED FROM THE MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac™
glueboard. Use of non-approved glueboards may invalidate your guarantee.
To replace the glueboard…
1. Remove the used glupac™ glueboard by simply lifting it clear from the
unit and either retain for catch evaluation or dispose of it hygienically.
2. Remove the protective release paper from the new glupac™ glueboard.
3. Slowly slide the new glupac™ glueboard into position along the two
runners with the adhesive side facing the tubes.
Always ensure the selected genuine glupac™ glueboards are compatible with your
unit, available from your PCO or P+L Systems Ltd.
TUBE REPLACEMENT
BEFORE REPLACING THE TUBES, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
To ensure the efficiency of Flytrap ProfessionalTM in catching flying insects, the UV
tubes should be replaced annually. After twelve months the phosphor coating that
emits the correct wavelength of UV light has burnt away and the UV output is
diminished substantially.
To replace the UV tubes…
1. Rotate the tube through 90°, freeing it from the tube holders.
2. Pull the tube away from the chassis.
3. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
BEFORE REPLACING THE STARTERS, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tube. Starters wear out and
should be replaced at the same intervals as the UV tubes.
To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
Glueboard Replacement
WEEE Compliance No. 01576542
C2009
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
R3 02/09
FTP30, 40 & 80
R3 02/09
FTP 30 200mm
FTP 40/80 200mm
FTP 30 269mm
FTP 40/80 399mm
FTP 30 80mm
FTP 40/80 84mm
FTP 30 17"
FTP 40/80 23 2/8"
FTP 30 464mm
FTP 40/80 616mm
Suspended
Horizontal Slimline
Vertical Slimline
Wall Corner
Discreet Wall
Desktop Corner
Desktop
FTP 30 432mm
FTP 40/80 591mm
(Chains Not Supplied)
MOUNTING INSTRUCTIONS
Professional Glueboard Insect Control

This manual suits for next models

3

Other PL Systems Insect Control Equipment manuals

PL Systems PlusZap PZ16 User manual

PL Systems

PL Systems PlusZap PZ16 User manual

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems Luralite Plus User manual

PL Systems

PL Systems Luralite Plus User manual

PL Systems PlusLight 30 User manual

PL Systems

PL Systems PlusLight 30 User manual

PL Systems Satalite 18 User manual

PL Systems

PL Systems Satalite 18 User manual

PL Systems EXOCUTER EX6 User manual

PL Systems

PL Systems EXOCUTER EX6 User manual

PL Systems Flypod User manual

PL Systems

PL Systems Flypod User manual

PL Systems FTC30 User manual

PL Systems

PL Systems FTC30 User manual

PL Systems flypod User manual

PL Systems

PL Systems flypod User manual

Popular Insect Control Equipment manuals by other brands

DynaTrap DT1120 LED owner's manual

DynaTrap

DynaTrap DT1120 LED owner's manual

Mi DWX01ZM quick start guide

Mi

Mi DWX01ZM quick start guide

Moskitrap GM966 instruction manual

Moskitrap

Moskitrap GM966 instruction manual

MistAway GEN III Operation manual

MistAway

MistAway GEN III Operation manual

Radarcan PLUS R-100 Instructions for use

Radarcan

Radarcan PLUS R-100 Instructions for use

ThermaCell E Series user guide

ThermaCell

ThermaCell E Series user guide

Flextailgear TINY REPEL user guide

Flextailgear

Flextailgear TINY REPEL user guide

ThermaCell MR300 Directions for use

ThermaCell

ThermaCell MR300 Directions for use

BASF Vector Plasma Grill instruction manual

BASF

BASF Vector Plasma Grill instruction manual

ThermaCell Tick control tubes quick start guide

ThermaCell

ThermaCell Tick control tubes quick start guide

Alcochem Hygiene i-trap 120E WP instruction manual

Alcochem Hygiene

Alcochem Hygiene i-trap 120E WP instruction manual

Stinger BK110 owner's manual

Stinger

Stinger BK110 owner's manual

NoSquito MA06 owner's manual

NoSquito

NoSquito MA06 owner's manual

OYPLA Home 4013 user manual

OYPLA Home

OYPLA Home 4013 user manual

ThermaCell MR300F Directions for use

ThermaCell

ThermaCell MR300F Directions for use

Isotra PS3 V MEASUREMENT AND ASSEMBLY MANUAL

Isotra

Isotra PS3 V MEASUREMENT AND ASSEMBLY MANUAL

auna sena Series quick start guide

auna

auna sena Series quick start guide

Lentek BugVacuum BV01 Directions for use

Lentek

Lentek BugVacuum BV01 Directions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.