Please read these instructions carefully and store in a safe
place for future reference.
Focus
As part of the Insect-O-Cutor®brand of insect control
products, the Focus range is an effective range of professional
flykillers which utilise highly effective Synergetic®UV tubes.
Constructed from coated mild steel, the Focus range can be
wall mounted, ceiling suspended or desk mounted.
Contents of package
- 1 x Insect-O-Cutor flykiller
- 1 x Mains cable (Type X)
- 1 x Removable catch tray (Fitted and wrapped)
- 2 x Wall mounting screws and wall plugs
- 2 x Suspension hooks
- 2 x Suspension chains
- 1 x High powered UV tube (F1 - Fitted)
or
- 2 x High powered UV tubes (F2 - Fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED (CLASS 1)
INSECT CONTROL PRODUCTS
The Focus range utilises high powered ultra violet tubes to
attract flying insects and then electrocutes them on a killing
grid, before collecting them in a removable catch tray.
WARNING
The Focus range is not to be used by persons with reduced
physical, sensory or mental capabilities, or lack of experience
and training, unless they have been given instruction.
Children should be supervised to ensure they do not play with
the appliance.
If the mains cable is damaged it must be replaced by a
specialist mains cable available from P+L Systems Ltd or your
supplier.
The Focus range must only be used in areas which are free of
dust and any possible explosive vapour mixture, are suitable
for indoor use only and are not suitable for use in barns,
stables and similar locations.
POSITIONING AND GUIDANCE FOR USE
The Focus range should ideally be fixed around two meters
above the ground, preferably in the darkest place within the
area to be protected. Do not position the unit close to
windows, skylights or other sources of light, or where it may be
obscured by furniture, doors or other obstacles.
The Focus range should ideally be in operation for 24 hours a
day, ensuring your premises are kept free of flying insects.
Insects are most attracted to the Focus range at night when
there is no competition from daylight or other light sources.
GUARANTEE
The Focus range has a five year guarantee and if maintained
as recommended in these instructions, should continue to
work for many years*. Use of non-approved consumables may
invalidate the guarantee.
*Excludes tubes. Does not cover breakdown due to misuse, incorrect operation or use in an
incorrect application.
INSTALLATION
INSTALLATION SHOULD BE CARRIED OUT BY SERVICE
PERSONNEL ONLY.
Before installation, first remove the plastic tie-wraps that are
securing the removable killing grid in place during transit. The
Focus range should be mounted as shown in the mounting
options section of this document. Keep out of reach of
children.
Wall Mounting - Install the supplied wall plugs and screws to
the mounting surface, having first made sure that appropriate
wall plugs are used for specialist mounting materials, such as
plasterboard.
Ceiling Suspension - Fit the suspension hooks to the top of the
unit, by first removing the two top screws, then replacing them
with the suspension hooks in place. Then fix the suspension
chains to the hooks. The Focus range should be hung 2 - 3m
from the ground, so if the supplied chains do not allow this,
chains of appropriate length and strength should be sourced.
Once installed into position, use the removable mains lead
and plug to connect the Focus range to an appropriate
power supply, as specified on the specification label found on
the flykiller.
CLEANING
CLEANING SHOULD BE CARRIED OUT BY SERVICE PERSONNEL
ONLY, AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM
THE MAINS SUPPLY.
It is recommended that cleaning is carried out regularly every
month. During cleaning the unit should be thoroughly wiped
down with a damp cloth, removing any build up of dirt.
Ensure the unit is completely dry before reconnecting it to the
power supply.
FOCUS
Professional Electric Insect Control Focus
Mounting Options
Wall
Desk
Suspended
Catch Tray & Guard RemovalCatch Tray & Guard Removal
SPECIFICATION / REPLACEMENT PARTS
Unit F1
Voltage 230V ~ 50Hz
Dimensions(mm) 268 x 300 x 115
Coverage 45 Sq. Meters
Weight 4.1 Kg
Light Output 11W
Tubes 1 x TGX11
Starter N/A
Unit F2
Voltage 230V ~ 50Hz
Dimensions(mm) 360 x 300 x 115
Coverage 90 Sq. Meters
Weight 4.6 Kg
Light Output 22W
Tubes 2 x TGX11
Starter N/A
MOUNTING FIXING CENTRES
METHOD F1 F2
Wall 130mm 216mm
Suspended 258mm 345mm
CATCH TRAY AND FRONT GUARD REMOVAL
To remove the front guard, the catch tray must first be removed as shown to the right. The
front guard is connected to the power supply of the unit via a hidden switch. By removing
the front guard the connection is broken and power is cut to the unit. This ensures safe
access to the unit for servicing and cleaning.
NB - WHEN REPLACING THE FRONT GUARD BACK INTO F1 AND F2, ENSURE IT IS PUSHED FULLY
INTO POSITION AND THAT POWER IS RESTORED TO THE UNIT.
NB - THE FRONT GUARD CAN ONLY BE RELEASED ONCE THE CATCH TRAY IS REMOVED
TUBE REPLACEMENT
TUBE REPLACEMENT SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY, AFTER
ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of the Focus range in catching flying insects, the UV tube(s) should
be replaced annually. After twelve months the phosphor coating that emits the correct
wavelength of UV light has burnt away and the UV output is diminished substantially.
To replace the UV tube(s)…
1. Remove the catch tray.
2. Remove the front guard.
3. Pull the tube away from the tube holder.
4. Dispose of the used UV tube in conjunction with local WEEE regulations.
KILLING GRID REMOVAL
REMOVAL OF THE KILLING GRID SHOULD BE CARRIED OUT BY SERVICE PERSONNEL ONLY,
AFTER ENSURING THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To help with servicing and cleaning, the killing grid within the Focus range can be removed.
To remove the killing grid...
1. Remove the catch tray.
2. Remove the front guard.
3. Remove the tube(s).
4. Pull the killing grid forward, to release it from the plastic clips.
5. Pull the killing grid down to free it from the unit.
2.
Catch Tray & Guard RemovalTube Replacement
2.
1
R2 01/14 WEEE Compliance No. WEE/GF0661QR
C2014
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
Sterling House
Grimbald Crag Close
Knaresborough
North Yorkshire
HG5 8PJ UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
Catch Tray & Guard RemovalKilling Grid Removal

This manual suits for next models

2

Other PL Systems Insect Control Equipment manuals

PL Systems PlusLight 30 User manual

PL Systems

PL Systems PlusLight 30 User manual

PL Systems FTC30 User manual

PL Systems

PL Systems FTC30 User manual

PL Systems PlusZap PZ16 User manual

PL Systems

PL Systems PlusZap PZ16 User manual

PL Systems EXOCUTER EX6 User manual

PL Systems

PL Systems EXOCUTER EX6 User manual

PL Systems Flytrap Professional Series User manual

PL Systems

PL Systems Flytrap Professional Series User manual

PL Systems Luralite Plus User manual

PL Systems

PL Systems Luralite Plus User manual

PL Systems flypod User manual

PL Systems

PL Systems flypod User manual

PL Systems Flypod User manual

PL Systems

PL Systems Flypod User manual

PL Systems Satalite 18 User manual

PL Systems

PL Systems Satalite 18 User manual

Popular Insect Control Equipment manuals by other brands

Pelsis Insect-O-Cutor Halo Curve manual

Pelsis

Pelsis Insect-O-Cutor Halo Curve manual

Ryobi P2805 Operator's manual

Ryobi

Ryobi P2805 Operator's manual

Sonnenkonig MINISPIDER user manual

Sonnenkonig

Sonnenkonig MINISPIDER user manual

Stinger BKC40 Series Replacement

Stinger

Stinger BKC40 Series Replacement

Gemmy BUBBLE FOGGER 20931 instructions

Gemmy

Gemmy BUBBLE FOGGER 20931 instructions

Alcochem Hygiene i-trap 120E WP instruction manual

Alcochem Hygiene

Alcochem Hygiene i-trap 120E WP instruction manual

Rittenhouse Compu-Spray instruction manual

Rittenhouse

Rittenhouse Compu-Spray instruction manual

ARDES AR6S07 Instructions for use

ARDES

ARDES AR6S07 Instructions for use

Velux ZIL installation instructions

Velux

Velux ZIL installation instructions

Helen of Troy Kaz Stinger FP15 Series owner's manual

Helen of Troy

Helen of Troy Kaz Stinger FP15 Series owner's manual

Multi PSI Multi-160 Operator's manual

Multi PSI

Multi PSI Multi-160 Operator's manual

Bonide 46160 Mounting Hardware Instructions

Bonide

Bonide 46160 Mounting Hardware Instructions

Windhager EXPERT quick start guide

Windhager

Windhager EXPERT quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.