manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PL Systems
  6. •
  7. Insect Control Equipment
  8. •
  9. PL Systems PlusLight 30 User manual

PL Systems PlusLight 30 User manual

This manual suits for next models

3

Other PL Systems Insect Control Equipment manuals

PL Systems PlusZap PZ16 User manual

PL Systems

PL Systems PlusZap PZ16 User manual

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems Flytrap Professional Series User manual

PL Systems

PL Systems Flytrap Professional Series User manual

PL Systems Luralite Plus User manual

PL Systems

PL Systems Luralite Plus User manual

PL Systems FTC30 User manual

PL Systems

PL Systems FTC30 User manual

PL Systems Satalite 18 User manual

PL Systems

PL Systems Satalite 18 User manual

PL Systems EXOCUTER EX6 User manual

PL Systems

PL Systems EXOCUTER EX6 User manual

PL Systems Flypod User manual

PL Systems

PL Systems Flypod User manual

PL Systems flypod User manual

PL Systems

PL Systems flypod User manual

Popular Insect Control Equipment manuals by other brands

Gardigo 66643 instruction manual

Gardigo

Gardigo 66643 instruction manual

Starkeys L25 Instruction/Safety Sheet

Starkeys

Starkeys L25 Instruction/Safety Sheet

Stinger Nosquito CT100 Series Operation manual

Stinger

Stinger Nosquito CT100 Series Operation manual

Radarcan R-502 user manual

Radarcan

Radarcan R-502 user manual

FarmTek Growers supply 115106S manual

FarmTek

FarmTek Growers supply 115106S manual

Radarcan RODENTS REPELLER PRO Instructions for use

Radarcan

Radarcan RODENTS REPELLER PRO Instructions for use

Kasanova HOH000006 7 instruction manual

Kasanova

Kasanova HOH000006 7 instruction manual

Emil Lux 306232 Original instructions

Emil Lux

Emil Lux 306232 Original instructions

Coleman Mosquito Deleto 2200 Instructions for use

Coleman

Coleman Mosquito Deleto 2200 Instructions for use

Pelsis Synergetic Halo 15W manual

Pelsis

Pelsis Synergetic Halo 15W manual

Paraclipse Mosquito Eliminator Maintenance instructions

Paraclipse

Paraclipse Mosquito Eliminator Maintenance instructions

Eastern Tabletop Go Clean Germbuster manual

Eastern Tabletop

Eastern Tabletop Go Clean Germbuster manual

deerma CM1300W manual

deerma

deerma CM1300W manual

Susan McKnight Climbup Directions for use

Susan McKnight

Susan McKnight Climbup Directions for use

Abus Junior Care Jan JC8320 manual

Abus

Abus Junior Care Jan JC8320 manual

Garrard Fly Catcher Instructions for use

Garrard

Garrard Fly Catcher Instructions for use

Fountainhead Black Flag user manual

Fountainhead

Fountainhead Black Flag user manual

Rentokil Lumnia Slim US instruction manual

Rentokil

Rentokil Lumnia Slim US instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PL30 & PL60
Please read these instructions carefully and store in a safe
place for future reference.
PLUSLIGHT ™
As part of the P+L brand of insect control products, PlusLight™
is an effective and easily serviceable commercial flykiller
which utilises highly effective UV tubes and is designed for use
with a high specification glupac™glueboard. Two sizes of unit
are available, PlusLight™ 30 which can be desk or wall
mounted and PlusLight™ 60 which can be ceiling suspended.
Contents of package
- 1 x PlusLight™flykiller
- 1 x glupac™pheromone impregnated glueboard
- 2 x Screws and wall plugs (Pluslight™30 Only)
- 2 x Suspension keyrings and chain (Pluslight™60 Only)
- 1 x Mains cable
- 2 x High powered UV tubes (Fitted)
or
- 4 x High powered UV tubes (Fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED
INSECT CONTROL PRODUCTS
PlusLight™utilises high powered ultra violet tubes to attract
flying insects and retains the caught insects on a pheromone
impregnated glueboard for inspection or hygienic disposal.
POSITIONING
THIS UNIT IS FOR INDOOR USE ONLY.
PlusLight™should ideally be fixed around two meters above
the ground, preferably in the darkest place within the area to
be protected and is supplied with a two meter mains lead.
Do not position the unit close to windows, skylights or other
sources of light, or where it may be obscured by furniture,
doors or other obstacles. Ideally, PlusLight™units should be
visible from every part of the area to be protected.
INSTALLATION
PRIOR TO INSTALLATION, ENSURE THE POWER SUPPLY OF YOUR
MAINS OUTLET CORRESPONDS TO THAT MARKED ON THE
SPECIFICATION LABEL FOUND ON THE FLYKILLER.
PlusLight™should be mounted as shown in the mounting
options section of this document. Once installed in position,
fit the glupac™glueboard in position as described in the
glueboard replacement section of this document. Use the
removable mains lead and plug to connect the PlusLight™to
an appropriate power supply.
WARNING - THIS APPLIANCE MUST BE EARTHED
USING PLUSLIGHT ™
PlusLight™should ideally be in operation for 24 hours a day,
ensuring your premises are kept free of flying insects. Insects
are most attracted to PlusLight™units at night when there is no
competition from daylight or other light sources.
CLEANING
ENSURE THAT THE FLYING INSECT KILLER IS DISCONNECTED
FROM THE MAINS BEFORE CLEANING
It is recommended that cleaning is carried out regularly when
the glueboard is replaced. Once the glueboard is removed,
the unit should be thoroughly wiped down with a damp
cloth, removing any build up of dirt. Ensure the unit is
completely dry before reconnecting it to the power supply.
GUARANTEE
PlusLight™has a two year guarantee and if maintained as
recommended in these instructions should continue to work
for many years.* Use of non-approved consumables may
invalidate the guarantee. Ensure genuine glupac™
glueboards are used in conjunction with this product.
*Excludes tubes, glueboards and starters. Does not cover breakdown due to misuse,
incorrect operation or use in an incorrect application.
MOUNTING FIXING CENTRES
Method PL30 PL60
Wall 300mm -
Suspended - 470mm
Commercial Glueboard Insect Control
Mounting Options
PlusLight™30 Wall
PlusLight™30 Desk
PlusLight™60
Suspended
Tube Replacement
Commercial Glueboard Insect Control
Starter Replacement
SPECIFICATION / REPLACEMENT PARTS
Unit PL30 White
Voltage 230V ~ 50Hz
Dimensions(mm) 470 x 285 x 90
Coverage 80 Sq. Meters
Weight 4 Kg
Light Output 30W
Tubes 2 x I616
Starter 2 x I154
Glueboards (x6) INF209
Unit PL60 S/S
Voltage 230V ~ 50Hz
Dimensions(mm) 470 x 330 x 130
Coverage 80 Sq. Meters
Weight 7 Kg
Light Output 60W
Tubes 4 x I616
Starter 4 x I154
Glueboards (x6) INF209
GLUEBOARD REPLACEMENT
BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE
MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac™glueboard.
Use of non-approved glueboards may invalidate your guarantee.
To replace the glueboard…
PlusLight™30
1. Remove the mains cable from your PlusLight™.
2. Swing open the front guard untill it rests open against the fixing surface.
3. Remove the used glupac™glueboard by simply releasing from the metal
chassis and either retain for catch evaluation or dispose of it hygienically.
4. Remove the protective release paper from the new glupac™glueboard.
5. Carefuly position the new glupac™glueboard into position with the adhesive
side facing the tubes, ensuring the glueboard is held in position by the metal
clips at the top of the metal chassis.
PlusLight™60
1. Swing open the front guard untill it is held in position by the aluminium clips.
2. Remove the used glupac™glueboard by simply releasing from the metal
chassis and either retain for catch evaluation or dispose of it hygienically.
3. Remove the protective release paper from the new glupac™glueboard.
4. Carefuly position the new glupac™glueboard into position with the adhesive side
facing the tubes, ensuring the glueboard is held in position by the metal clips at the
top of the metal chassis.
5. Release the front guard by pulling the aluminium cilps away from the chassis.
Always ensure the selected genuine glupac™glueboards are compatible with your unit, available
from your PCO or P+L Systems Ltd.
TUBE REPLACEMENT
BEFORE REPLACING THE TUBES, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
To ensure the efficiency of PlusLight™in catching flying insects, the UV tubes should be replaced
annually. After twelve months the phosphor coating that emits the correct wavelength of UV
light has burnt away and the UV output is diminished substantially.
To replace the UV tubes…
1. Rotate the tube through 90°, freeing it from the tube holders.
2. Pull the tube away from the chassis.
3. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
BEFORE REPLACING THE STARTERS, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tube. Starters wear out and should be
replaced at the same intervals as the UV tubes.
To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
Glueboard Replacement
C2008
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
R2 04/08