manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. PL Systems
  6. •
  7. Insect Control Equipment
  8. •
  9. PL Systems Luralite Plus User manual

PL Systems Luralite Plus User manual

Luralite Plus
Please read these instructions carefully and store in a safe
place for future reference.
LURALITE PLUS
As part of the P+L brand of insect control products, Luralite
PlusTM is an easy to service and highly effective decorative
insect control unit for use within front of house applications.
Luralite PlusTM utilises highly effective UV tubes and is designed
for use with a high specification glupac™glueboard.
Contents of package
- 1 x Luralite Plus™flykiller
- 1 x glupac™pheromone impregnated glueboard
- 2 x Screws and wall plugs
- 2 x 15W High powered insect attractive UV tubes (fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED
INSECT CONTROL PRODUCTS
Luralite PlusTM utilises high powered ultra violet tubes to attract
flying insects and retains the caught insects on a pheromone
impregnated glueboard for inspection or hygienic disposal.
POSITIONING
THIS UNIT IS FOR INDOOR USE ONLY.
Luralite PlusTM should ideally be fixed around two metres
above the ground, preferably in the darkest place within the
area to be protected and is supplied with a two meter mains
lead. Do not position the unit close to windows, skylights or
other sources of light, or where it may be obscured by
furniture, doors or other obstacles. Ideally, Luralite PlusTM units
should be visible from every part of the area to be protected.
INSTALLATION
PRIOR TO INSTALLATION, ENSURE THE POWER SUPPLY OF YOUR
MAINS OUTLET CORRESPONDS TO THAT MARKED ON THE
SPECIFICATION LABEL FOUND ON THE FLYKILLER.
Luralite PlusTM should be fixed to the wall with the supplied wall
plugs and screws. Once installed in position, fit the glupac™
glueboard in position as described in the glueboard
replacement section of this document. Luralite PlusTM has a
plug fitted to the mains lead and once installed in position,
should be plugged into the nearest mains outlet.
WARNING - THIS APPLIANCE MUST BE EARTHED
USING LURALITE PLUS
Luralite PlusTM should ideally be in operation for 24 hours a day,
ensuring your premises are kept free of flying insects. Insects
are most attracted to Luralite PlusTM at night when there is no
competition from daylight or other light sources.
CLEANING
ENSURE THAT THE FLYING INSECT KILLER IS DISCONNECTED
FROM THE MAINS BEFORE CLEANING.
It is recommended that cleaning is carried out regularly when
the glueboard is replaced. Once the glueboard is removed,
the unit should be thoroughly wiped down with a damp
cloth, removing any build up of dirt. Ensure the unit is
completely dry before reconnecting it to the power supply.
GUARANTEE
Luralite PlusTM has a two year guarantee and if maintained as
recommended in these instructions should continue to work
for many years.* Use of non-approved consumables may
invalidate the guarantee. Ensure genuine glupac™
glueboards are used in conjunction with this product.
*Excludes tubes, glueboards and starters. Does not cover breakdown due to misuse,
incorrect operation or use in an incorrect application.
Glueboard Installation
Decorative Glueboard Insect Control
Decorative Glueboard Insect Control
C2008
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
Starter Replacement Tube Replacement (Professional)
SPECIFICATION / REPLACEMENT PARTS
GLUEBOARD REPLACEMENT
BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE
MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac™glueboard. Use of
non-approved glueboards may invalidate your guarantee.
To replace the glueboard…
1. Swing open the front guard by first lifting it up, then pulling forward.
2. Remove the used glupac™glueboard by simply sliding it out from the top of the unit
and either retain for catch evaluation or dispose of it hygienically.
3. Remove the protective release paper from the new glupac™glueboard.
4. Slowly slide the new glupac™glueboard into position with the adhesive side facing
the tubes.
5. Replace the front guard by reversing the first step.
Always ensure the selected genuine glupac™glueboards are compatible with your unit,
available from your PCO or P+L Systems Ltd.
TUBE REPLACEMENT
BEFORE REPLACING THE TUBES, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE MAINS
SUPPLY.
To ensure the efficiency of Luralite PlusTM in catching flying insects, the UV tubes should be
replaced annually. After twelve months the phosphor coating that emits the correct wavelength
of UV light has burnt away and the UV output is diminished substantially.
To replace the UV tubes…
Luralite Plus 1. Rotate the tube through 90 degrees.
2. Gently pull the tube away from the unit.
3. Reverse the process with the replacement tube.
STARTER REPLACEMENT
BEFORE REPLACING THE STARTERS, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED FROM THE
MAINS SUPPLY.
The starters provides an extra spark to initially light the UV tubes. Starters wear out and should be
replaced at the same intervals as the UV tubes.
To replace the starters…
1. Swing open the front guard by first lifting it up, then pulling forward.
2. Rotate the starter anti-clockwise.
3. Pull the starter free from the unit.
4. Replace the front guard by reversing the first step.
R2 05/08
Unit Luralite Plus
Voltage 230V ~ 50Hz
Dimensions(mm) 625 x 220 x 155
Coverage 50 Sq. Metres
Weight 2.5 Kg
Light Output 30W
Tubes 2 x I616
Starter 2 x I154
Glueboards (x6) INL199
Wall Fixing points 380mm

Other PL Systems Insect Control Equipment manuals

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems PlusZap PZ16 User manual

PL Systems

PL Systems PlusZap PZ16 User manual

PL Systems flypod User manual

PL Systems

PL Systems flypod User manual

PL Systems FTC30 User manual

PL Systems

PL Systems FTC30 User manual

PL Systems Satalite 18 User manual

PL Systems

PL Systems Satalite 18 User manual

PL Systems EXOCUTER EX6 User manual

PL Systems

PL Systems EXOCUTER EX6 User manual

PL Systems Flypod User manual

PL Systems

PL Systems Flypod User manual

PL Systems PlusLight 30 User manual

PL Systems

PL Systems PlusLight 30 User manual

PL Systems Flytrap Professional Series User manual

PL Systems

PL Systems Flytrap Professional Series User manual

Popular Insect Control Equipment manuals by other brands

GARDEN SECRETS GS-502 User instructions

GARDEN SECRETS

GARDEN SECRETS GS-502 User instructions

MistAway Mosquito manual

MistAway

MistAway Mosquito manual

Yardistry YM12834 installation instructions

Yardistry

Yardistry YM12834 installation instructions

ThermaCell MR150 quick start guide

ThermaCell

ThermaCell MR150 quick start guide

Cardigo 60048 instruction manual

Cardigo

Cardigo 60048 instruction manual

TBI Pro Indoor BUG ZAPPER user manual

TBI Pro

TBI Pro Indoor BUG ZAPPER user manual

Lentek BiteShield Mosquito Trap Champion quick start guide

Lentek

Lentek BiteShield Mosquito Trap Champion quick start guide

Gardigo 25157 instruction manual

Gardigo

Gardigo 25157 instruction manual

Dynamic DynaTrap DT1200 owner's manual

Dynamic

Dynamic DynaTrap DT1200 owner's manual

Mega Catch MCU800 Operation manual

Mega Catch

Mega Catch MCU800 Operation manual

DynaTrap DT1100 owner's manual

DynaTrap

DynaTrap DT1100 owner's manual

Neher DF-2016-1 Application notes

Neher

Neher DF-2016-1 Application notes

Manrose MANPFK instructions

Manrose

Manrose MANPFK instructions

Pessl iMETOS iSCOUT Color Trap user manual

Pessl

Pessl iMETOS iSCOUT Color Trap user manual

Vector Fog H100 manual

Vector Fog

Vector Fog H100 manual

BlueRhino SkeeterVac SV-35 owner's manual

BlueRhino

BlueRhino SkeeterVac SV-35 owner's manual

Mosquito Sentry Portable GS-1018 instructions

Mosquito Sentry

Mosquito Sentry Portable GS-1018 instructions

MedNovis MosQuit Directions for use

MedNovis

MedNovis MosQuit Directions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.