PL Systems FTC30 User manual

FTC30, 40 & 80
Please read these instructions carefully and store in a safe
place for future reference.
FLYTRAP COMMERCIALTM
As part of the P+L brand of insect control products, Flytrap
Commercial
TM is an effective and versatile commercial flykiller
which utilises highly effective UV tubes and is designed for use
with a high specification glupac™ glueboard. Three sizes of
unit are available and Flytrap Commercial
TM can be ceiling
suspended, discreet or slimline wall mounted.
Contents of package
- 1 x Flytrap Commercial flykiller
- 1 x glupac™ pheromone impregnated glueboard
- 4 x Screws and wall plugs
- 2 x Suspension keyrings
- 2 x Slimline mounting wall brackets
- 2 x Discreet mounting wall brackets
- 1 x Mains cable
- 2 x High powered UV tubes (Fitted)
WARNING - THIS APPLIANCE MUST BE EARTHED
INSECT CONTROL PRODUCTS
Flytrap Commercial
TM utilises high powered ultra violet tubes
to attract flying insects and retains the caught insects on a
pheromone impregnated glueboard for inspection or
hygienic disposal.
POSITIONING
THIS UNIT IS FOR INDOOR USE ONLY.
Flytrap Commercial
TM should ideally be fixed around two
meters above the ground, preferably in the darkest place
within the area to be protected and is supplied with a two
meter mains lead. Do not position the unit close to windows,
skylights or other sources of light, or where it may be
obscured by furniture, doors or other obstacles. Ideally,
Flytrap Commercial
TM units should be visible from every part of
the area to be protected.
INSTALLATION
PRIOR TO INSTALLATION, ENSURE THE POWER SUPPLY OF YOUR
MAINS OUTLET CORRESPONDS TO THAT MARKED ON THE
SPECIFICATION LABEL FOUND ON THE FLYKILLER.
Flytrap Commercial
TM can be mounted in three different ways
as shown in the mounting options section of this document.
Once installed in position, fit the glupac™ glueboard in
position as described in the glueboard replacement section
of this document. Use the removable mains lead and plug to
connect the Flytrap Commercial
TM to an appropriate power
supply.
WARNING - THIS APPLIANCE MUST BE EARTHED
USING FLYTRAP COMMERCIALTM
Flytrap Commercial
TM should ideally be in operation for 24
hours a day, ensuring your premises are kept free of flying
insects. Insects are most attracted to Flytrap Commercial
TM
unit at night when there is no competition from daylight or
other light sources.
CLEANING
ENSURE THAT THE FLYING INSECT KILLER IS DISCONNECTED
FROM THE MAINS BEFORE CLEANING
It is recommended that cleaning is carried out regularly when
the glueboard is replaced. Once the glueboard is removed,
the unit should be thoroughly wiped down with a damp
cloth, removing any build up of dirt. Ensure the unit is
completely dry before reconnecting it to the power supply.
GUARANTEE
Flytrap Commercial
TM has a three year guarantee and if
maintained as recommended in these instructions should
continue to work for many years.* Use of non-approved
consumables may invalidate the guarantee. Ensure genuine
glupac™ glueboards are used in conjunction with this
product.
*Excludes tubes, glueboards and starters. Does not cover breakdown due to misuse,
incorrect operation or use in an incorrect application.
Mounting Options
MOUNTING FIXING CENTRES
METHOD FTC30 FTC40 FTC80
Slimline 305mm 458mm 458mm
Discreet 305mm 458mm 458mm
Suspended 506mm 668mm 668mm
Slimline Wall
Discreet Wall
Suspended
(Chain not supplied)
Commercial Glueboard Insect Control
Tube ReplacementStarter Replacement
SPECIFICATION / REPLACEMENT PARTS
Unit FTC30
Voltage 230V ~ 50Hz
Dimensions(mm) 470 x 185 x 355
Coverage 80 Sq. Meters
Weight 4 Kg
Light Output 30W
Tubes 2 x I616
Starter 2 x I154
Glueboards (x6) INF060
Unit FTC40
Voltage 230V ~ 50Hz
Dimensions(mm) 623 x 185 x 355
Coverage 120 Sq. Meters
Weight 5 Kg
Light Output 40W
Tubes 2 x I618
Starter 2 x I154
Glueboards (x6) INF061
Unit FTC80
Voltage 230V ~ 50Hz
Dimensions(mm) 623 x 185 x 355
Coverage 240 Sq. Meters
Weight 5 Kg
Light Output 80W
Tubes 2 x I662
Starter 2 x I154
Glueboards (x6) INF061
GLUEBOARD REPLACEMENT
BEFORE REPLACING THE GLUEBOARD, ALWAYS ENSURE THAT THE UNIT IS
DISCONNECTED FROM THE MAINS SUPPLY.
The glueboard should be replaced every month with a genuine glupac™
glueboard. Use of non-approved glueboards may invalidate your guarantee.
To replace the glueboard…
1. Remove the used glupac™ glueboard by simply releasing from the metal
outer and either retain for catch evaluation or dispose of it hygienically.
2. Remove the protective release paper from the new glupac™ glueboard.
3. Fold the locating flap into position along the score line.
4. Slowly slide the new glupac™ glueboard into position with the adhesive
side facing the tubes.
Always ensure the selected genuine glupac™ glueboards are compatible with your
unit, available from your PCO or P+L Systems Ltd.
TUBE REPLACEMENT
BEFORE REPLACING THE TUBES, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
To ensure the efficiency of Flytrap Commercial
TM in catching flying insects, the UV
tubes should be replaced annually. After twelve months the phosphor coating that
emits the correct wavelength of UV light has burnt away and the UV output is
diminished substantially.
To replace the UV tubes…
1. Rotate the tube through 90°, freeing it from the tube holders.
2. Pull the tube away from the chassis.
3. Dispose of the used UV tube in conjunction with local WEEE regulations.
STARTER REPLACEMENT
BEFORE REPLACING THE STARTERS, ALWAYS ENSURE THAT THE UNIT IS DISCONNECTED
FROM THE MAINS SUPPLY.
The starters provide an extra spark to initially light the UV tube. Starters wear out and
should be replaced at the same intervals as the UV tubes.
To replace the starters…
1. Rotate the starter anti-clockwise.
2. Pull the starter free from the unit.
Glueboard Replacement
C2009
P+L Systems Ltd
Information provided on these instructions is modified and
updated from time to time. This is due to the constant
redevelopment of our products. As such, it is not intended that
you should rely on it or that it should form part of any contract.
P+L Systems Ltd
Ten St James Business Park
Grimbald Crag Court
Knaresborough
HG5 8QB UK
T +44 (0)800 988 5359
F +44 (0)1423 863 497
W www.pandlsystems.com
E [email protected]
R2 02/09 WEEE Compliance No. 01576542

This manual suits for next models

2

Other PL Systems Insect Control Equipment manuals

PL Systems PlusLight 30 User manual

PL Systems

PL Systems PlusLight 30 User manual

PL Systems Flytrap Professional Series User manual

PL Systems

PL Systems Flytrap Professional Series User manual

PL Systems Flypod User manual

PL Systems

PL Systems Flypod User manual

PL Systems Satalite 18 User manual

PL Systems

PL Systems Satalite 18 User manual

PL Systems PlusZap PZ16 User manual

PL Systems

PL Systems PlusZap PZ16 User manual

PL Systems flypod User manual

PL Systems

PL Systems flypod User manual

PL Systems EXOCUTER EX6 User manual

PL Systems

PL Systems EXOCUTER EX6 User manual

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems

PL Systems INSECT-O-CUTOR Focus Series User manual

PL Systems Luralite Plus User manual

PL Systems

PL Systems Luralite Plus User manual

Popular Insect Control Equipment manuals by other brands

Lafferty 950721-TD Installation & operation instructions

Lafferty

Lafferty 950721-TD Installation & operation instructions

BlueRhino SkeeterVac SV-35 owner's manual

BlueRhino

BlueRhino SkeeterVac SV-35 owner's manual

Vector Fog DC20+ user manual

Vector Fog

Vector Fog DC20+ user manual

MV LINE LATERAL IRENE installation instructions

MV LINE

MV LINE LATERAL IRENE installation instructions

DynaTrap DT2000XLP-TN19 owner's manual

DynaTrap

DynaTrap DT2000XLP-TN19 owner's manual

Pessl iMETOS iSCOUT user manual

Pessl

Pessl iMETOS iSCOUT user manual

FMC FirstLine 1629 quick start guide

FMC

FMC FirstLine 1629 quick start guide

Pelsis Synergetic Halo 15W manual

Pelsis

Pelsis Synergetic Halo 15W manual

ZappBug ZappBug Heater user manual

ZappBug

ZappBug ZappBug Heater user manual

BioMetrixx S1 quick start guide

BioMetrixx

BioMetrixx S1 quick start guide

Radarcan PLUS R-100 Instructions for use

Radarcan

Radarcan PLUS R-100 Instructions for use

Pelsis B&G FLEX-A-LITE 2600 user manual

Pelsis

Pelsis B&G FLEX-A-LITE 2600 user manual

Cardigo 60048 instruction manual

Cardigo

Cardigo 60048 instruction manual

Hoberg 07660 manual

Hoberg

Hoberg 07660 manual

Mega Catch Premier MCP800 Operation manual

Mega Catch

Mega Catch Premier MCP800 Operation manual

Streamline Vivid PRO SF-FG03-220 instruction manual

Streamline

Streamline Vivid PRO SF-FG03-220 instruction manual

SkeeterVac SV3501C instructions

SkeeterVac

SkeeterVac SV3501C instructions

Bo-Camp ATOM instruction manual

Bo-Camp

Bo-Camp ATOM instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.