Polyaire ZoneMaser ZoneTouch V2 User manual

ZoneTouch V2
Zone Control System
User Manual
www.polyaire.com.au
©2014 Polyaire Pty Ltd

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
II

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 1
1) Features 2
2) Wall Controller Layout (Touch Screen) 3
3) Manual Group Control 4
3.1 Group On/Off/Turbo 4
3.2 Adjusting airflow for a group 5
4) Automated Group Control 5
4.1 Set Program 6
4.2 Select Program for a Group 7
5) User Settings 8
5.1 Time/Date setup 8
5.2 Owner’s Name 9
5.3 Turbo Group 9
5.4 Temperature Display 10
5.5 Touch Tone 10
6) Information Sheets 11
7) Troubleshooting Guide 14
8) Specifications 15
TABLE OF CONTENTS
Liability
Please read the instructions before installing this Zonemaster Zoning Control System.
Polyaire Pty Ltd does not accept any responsibility for loss or damage that may occur as a result of the incorrect
installation of this Zonemaster Control System.

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
2
1) Features
• Userfriendlylargetouchscreeninterface
• Intuitiveuserinterface
• Controlairowtoindividualzones1and groups2
• ColourLCDforclearerdisplay
• Personalizedsystemsettingsandlabelling
• Wallmountedwithuptotwotouchscreensavailableinasystem
• 5-1-1ProgrammableOn/Otimeprograms
• Oneselectableturbo3group to cool/heat a particular area quicker
• Halfyear,OneyearandTwoyearservicereminderstocalltechnicianforcleaning
andservicingACsystem4.
• Allzonesautomaticallyresumetheiroriginalon/ostateoncepowerisrestored
afterpoweroutage.
1. A zone is the area where air supply is controlled by one motorized damper
2. A group is a few zones grouped together which have the group name and are controlled (turning on and
o,oradjustingopeningpercentage)atthesametime.Agroupwillhaveatleastonezoneandnomore
than four zones.
3. Turbo function will give the selectedgroupafull-openingwhileallothergroups’(dampers)opening
positions are reduced by 50% of their open percentage value. This will bring a large volume of extra air
into the designated area and cool or heat the area quicker.
4. AC system is the ducted air conditioner which has ZoneTouch V2 as its zone control system.

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 3
2) Wall Controller Layout (Touch Screen)
The home screen of the system willnormallydisplaygroups’status,dampers’open
percentagewithadjustingbuttons,date,time,roomtemperature,touchtonestatus
andZoneTouchlogoasshowninFigure1.
NOTE:
• The touch screen will go to the sleep mode after 90 seconds of inactivity.
In sleep mode, the screen is blank. Touching any area of the screen will
activate the system.
• To clean the touch screen, use a dry, soft cloth and very gently wipe the
screen. If necessary, dampen the cloth with distilled water or with an
equal ratio of distilled water to white vinegar.
Home Screen (Figure 1)

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
4
3) Manual Group control
3.1 GroupOn/O/Turbo
a) Onthehomescreen,touchagroupbutton(Figure2)tochangetheon/o
groupstatusandthedampersofthegroupwillopenorcloseaccordingly.
b) Thegroupstatuscanbesetto‘TURBO’activewhenthegroupisspecied
asaturbogroup(referto5.3)andthegreyturboindicatorwillturnblueto
indicatetheTURBOfunctionisactive.Figure3showsthegroupstatus
sequence alternated by touching the group button.
c)Upto6groupbuttonsareshowninonescreenandtouch<or >to bring up
previousornextpage.
Figure 2
Figure 3

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 5
4) Automated Group Control
Automatedon/ocontrolforeachgroupisanimportantfeatureoftheZoneTouchV2
system.Thissystemhasthreeprogramscenarios,oneforweekdays(Mondayto
Friday),oneforSaturdayandoneforSundayrespectively.
Eachprogramscenariohas4programmableeventsperday:ontime1,otime1,on
time2andotime2.Eachprogrameventcanbeenabledanddisabledandthetime
canbeadjustedasdesired.Allfoureventsaredisabledinthefactorydefaultwith
settingsaslistedinthetablebelow.Userscancreateupto4programsusingthe
scenariosanddierenteventtimeslots.
NOTE: A group can have up to a maximum of 4 zones. Your installer would
have already set up your zones and groups.
3.2 Adjustingairowforagroup
•Thedamperopeningpercentageforeverygroupcanbeadjustedtocontrol
theamountofairowateveryoutletbetween10%and100%ofthebalanced
value(setupbyInstaller)at10%increments.
• Touch or buttons on the home screen to increase or decrease the
percentage opening for the corresponding group.
•TheairowwillbeunadjustableiftheTurbofunctionisactive.Pressing
andwillnotchangetheopeningpercentage.
NOTE: The Turbo function cannot be programmed. It is activated manually from
the touch screen as needed.
On time 1 O time 1 On time 2 O time 2
Monday to Friday 6.30AM 8.00AM 5.30PM 10.00PM
Saturday 7.30AM 12.30PM 6.00PM 11.30PM
Sunday 7.30AM 12.30PM 6.00PM 11.30PM

4.1 Set Program
Uptofourprograms can be created.
Touchingbuttonwillgobackto
the home screen from programming setting pages.
a) Touch Program buttons (e.g. )on‘programming’screen(Figure4)
toenterthescreen(Figure5)toselectscenariosandadjusttheeventtimes.
ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
6
Touch the button on the home screen
toenter‘Programming’screen(Figure4).
Figure 4.
Figure 6.
b) TouchadayoptionradiobuttontoselectMonday-Friday,Saturdayor
Sundayprogramtomodify.Touchthetimeswitchradiobuttonontheright
toenable/disableON/OFFtime.
c) Touchthehour,minuteorAM/PM
eldonthescreentohighlightit,
and then the and buttons
willappearonthescreen(Figure6).
Touchorbuttonstoadjust
the time.
NOTE: Afteranediteldis
highlighted,touchingthateldagain
will quit from the editable status and
the and will disappear.
Figure 5

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 7
Figure 7.
4.2 Select Program for a Group
Enterthe‘Assignment’screen(Figure
7) by touching on
programmingscreen(Figure4).
Assignmentscreenshowsthelistof
the current program of each group.
Touchingbuttonwillgobackto
thehomescreenfromAssignment
page.
Figure 8.
Figure 9.
Figure 10.
Touchtheprogrameldofagroupto
showallprogramoptions(Figure8).
Touchingaprogramoptionwillassign
theprogramtothegroup(Figure9).
Eachgroupcanbeassignedwithone
program from program1 to program4
(‘P1’to‘P4’),andthegroupwillnot
haveaprogramif‘No’isselected.Ifa
program has been assigned to a group,
theprogramindicatorwillappearon
thegroup(Figure10)ifanyofthefour
eventsintheprogramisenabled.
NOTE: Programs cannot be
assigned to a group with turbo
status. Record programs and groups
to ‘Table 5: Programs’ on Page 13

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
8
a) Touch on the home screen
(Figure1)enter“Settings”screen
(Figure11)
b) Touch to enter ‘user
settings’screen(Figure12)
InUserSetting,youcansetupdate
andtime,owner’sname,Turbogroup,
temperature display and touch tone.
Touchingbuttonwillgobackto
thehomescreenfromUsersetting
pages.
Figure 11.
Figure 12.
5) User Settings
Figure 13.
Figure 14.
5.1 Time/Date setup
a) Touch on the‘User
Settings’screen(Figure12)toenter
the time/date setup screen
(Figure13).
b) Hour,Minute,AM/PM,day,month
andyeareldswillbeshownonthe
screen.Touchtheeldwhichneed
tobemodied,thentouchor
buttontochangethevalue
(Figure14).
c) Touch buttontosavethe
changesandgobacktoUser
Setting page.

5.2 Owner’s Name
Themaximumlengthofthenameis16
letters.
Goto‘UserSettings’screen(Figure12).
Touch‘OwnersName’tochangethe
owner’snamebyusingthekeyboardshown
onthescreen(Figure15).Touchto
switchbetweenlowercaseanduppercase
andtouchtoconrmthenameor
touch or to cancel the change.
ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 9
Figure 15.
5.3 Turbo Group
Touch ‘TurboGroup’tospecifyagroupasaTurboGroup.Turbofunctionwillgive
theselectedgroupafull-openingwhileallothergroups’(dampers)openingpositions
arereducedby50%oftheiropenpercentagevalue.Thiswillbringalargevolumeof
extraairintothedesignatedareaandcoolorheattheareaquicker.Typicallythis
may be a family room, dining room or home theatre (or in commercial application a
meeting, lunch or board room).
Touch the‘TurboGroup’eldonthe‘User
Settings’screen(Figure12),todisplaythe
listofavailablegroupname(Figure16).
Choose the desired group name as the
turbogroup.Thegreyturboindicatorwill
appearonthegroupbuttonafterit’schosen
as Turbo group.
NOTE:Tomakethespeciedgroupstart
to work in turbo mode, the group status
needs to be turned to ‘turbo’ on the home
screen (3.1).
Figure 16.

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
10
5.4 Temperature Display
Touch the radio button of to enable or disable the temperature
displayonthetouchscreen.Belowimagesshowtheenabledstatus(Figure17)and
disabledstatus(Figure18)oftemperaturedisplay.
5.5 Touch Tone
The touch tone feature allowstoeitherenableordisablethetonewhenthescreenis
touched.Itisdisabledasdefaultandwilldisplayamutelogoonthescreen.
Touchtheradiobuttonoftoswitchthetouchtoneonoro.
Figure 17. Figure 18.

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 11
6) Information Sheets
Theseshouldbelledoutbytheinstaller
Total Groups Bypass Damper
Installed
Supply Air Sensor
Installed
Yes/No Yes/No
Group Group Name Zones Included Turbo Function
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
G
Table 1: System Conguration
Table 2: Grouping

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
12
Installer Contact Number Date
Zone Balance Percentage
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Zone 9
Zone A
Zone B
Zone C
Zone D
Zone E
Zone F
Zone G
Table 4: Installer Details
Table 3: Balance

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 13
Table 5: Programs
PROGRAM 1 On time 1 O time 1 On time 2 O time 2
Monday-Friday
Saturday
Sunday
Groups
PROGRAM 2 On time 1 O time 1 On time 2 O time 2
Monday-Friday
Saturday
Sunday
Groups
PROGRAM 3 On time 1 O time 1 On time 2 O time 2
Monday-Friday
Saturday
Sunday
Groups
PROGRAM 4 On time 1 O time 1 On time 2 O time 2
Monday-Friday
Saturday
Sunday
Groups

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
14
7) Troubleshooting Guide
PROBLEM SUGGESTED ACTION
Dampers have no
response when turned on
or o
• Checkifthe‘SafetyisActivated’errorisdisplayed.Highlimit(Heating)
orLowlimit(Cooling)mayhavereached.Checktheair-conditionerto
seeifitisoperatingnormally.ZoneTouchV2systemwillresumeto
operationalafterthesupplyairtemperatureiswithinsafetyrange.
• *CheckifSupplyairsensorispluggedinthemainboardandHighLimit
&LowLimitisenabled.Ifthesensorisnotpluggedin,plugthe
sensorandthesystemwillbeoperationalafteraminute.Ifthesensor
isnotrequired,disableHighlimitandLowlimitfromtouchpadand
systemwillreturntooperationalinaminute.
• *CheckifLEDsonthemainmodulelightupforrelevantzoneswhen
thezonedampersarebeingturnedOn/O.IfGreen/RedLEDsarenot
activatedfortherespectivezone,themainmodulemaybefaulty,replaceit.
• *Checkif the cable from touchpad to the main control module is faulty.
Ifitisafaultycable,thenthecablemighthavetobereplaced.
Some zones cannot
be turned o
• Checkif‘Spillisactivated’isdisplayedontheLCDscreen.
• Checkif‘Spill’statusisdisplayedfortheGroupstatusinthehome
screen.Openingotherzoneswillrectifytheerror
• *Ifallzonesareturnedonbutthetotalopeningpercentagedoesn’t
meettherequiredspillpercentage,thentheSPILLwarningmessage
willbedisplayed.Increasingtheopeningpercentageofafewzones
willresolvetheissue.
• *Checkspillset-point.
No display on the LCD • *Checkifthecableispluggedinproperly.Unplugthecableand
reconnect it.
• *Checkifthereispowertotheunit.
LCD Display
Corrupted
• ResetLCDbyholdingRESETbuttonatthebottomoftheTouchpadfor
2s.
• *Iferrorisstillnotresolved,resettouchpadbyunpluggingthecable
frombehindandthenreconnectitafteracoupleminutes.Ifthe
corrupteddisplayremains,powero/onthemainboard.Otherwise,
replace the touchpad.
Some zones are
not operational
• *CheckGroupingandndoutiftherightzoneshavebeenassignedto
therightgroupsandhavebeenturnedON/OFFinZoningsection.
• *Checkifthetotalgroupnumberandzonenumberarecorrect.
• *CheckiftheLEDsonthemainmodulelightupfortherelevantzones
whenthezonedampersareturnedOn/O.Ifthereisnoresponse,
theremightbeafaultycableandthecablewouldhavetobereplaced.
Ifthezoneisstillnon-functionalthentheremightbeafaultydamper
motor.
*: Thesechecksintheguideshouldbecarriedoutbyqualiedpersonnel.
If you have any doubt regarding the above please contact your installer.

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 15
8) Specications
Electrical Requirements
Powersupply: 24VAC±10%
Linefrequency: 50Hz
Components Power Consumption
Touchpad: 0.5VA
MainControlModule: 5VA
Environmental Requirements
Operatingtemperature: 0°Cto60°C
Altitude: 0to2000meters
Operatingrelativehumidity: 10%to80%
Avoidstaticelectricityhazards
Avoidelectromagneticradiationsources
Avoiddustcontamination
Avoidhighlycorrosiveenvironments
Zone Output
Outputvoltage: 24VAC,50Hz
Current: 200mA(1dampermotor)
Transformer
InputVoltage: 240VAC,50Hz
OutputVoltage: 24VAC,50Hz
Wattage: 40W
Supply Air Sensor: NTCtype,10kΩat25°C
Battery: 3.6V,3xAAAM
RechargeableforMainModule
Fuse: Dimension5x20mm,
Fast-Acting2A,250V

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual
16

ZONEMASTER ZONETOUCH V2 ZONE CONTROL SYSTEM - User Manual 17

ZMZT2_USER_V1.0
POLYAIRE PTY LTD
11-13WHITEROAD
GEPPSCROSS
SOUTHAUSTRALIA,5094
TEL:(08)83498466
FAX:(08)83498446
www.polyaire.com.au