PAD300-LFSB
Addressable Low Frequency Sounder Base
8830213- REV A • 10/22 PAGE 1 OF 2
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
Description
The Addressable Low Frequency Sounder Base (PAD300-LFSB) is a
sounder base that may be utilized in a variety of applications. The base
has a locking feature for the detector that may be used or removed in
the eld. Once the head is removed, the sounder is accessible in the
bottom of the unit.
The PAD300-LFSB low frequency sounder base is designed to meet
NFPA 72 sleeping space requirements to produce a frequency of 520
Hz +/- 10% with a square wave.
It is shown that a lower frequency, centered around 520 Hz, is the ideal
to awaken sleeping occupants, even those with mild to severe hearing
loss.
The base has an independent sounder module that may be programmed
as a single station, zone or all call sounder. The PAD300-LFSB
passes through the sound pattern sent to the sounder, therefore it may
reproduce in any pattern the power supply provides.
The PAD300-LFSB does not consume an address on the loop and
is fully programmable to operate with any input. Once activated the
sounder will also follow the input from the power source and de-
activate accordingly.
Technical Specications
SLC Voltage 24VDC
SLC Standby Current 300 µA
PWR Voltage 16-33 VDC
PWR Active Current 155mA
Alarm LED Current 1.4mA
Sound Pressure Level 75dB @ 10ft per UL464
85dB @ 10ft per UL268
Installation Temperature Range 32 to 150°F (0°C to 66°C)
Operating Humidity Range < 93% (Non-condensing)
Dimensions 6.4in (163 mm)
Weight 240 g (8.47 oz)
Height 1.57 in (40 mm)
Features
• Addressable low frequency sounder base, allows for single
station, grouped or all call activation
• May be mapped to any device connected to the control panel
• Terminals accept 22 to 12 AWG wire sizes
• Supports Class A, Class X and Class B wiring
• Does not require SLC Loop address, uses PAD sub point
addressing feature
• Complies with the Low Frequency Signal Requirements per
NFPA 72 and UL 464 for Audible Signaling Devices
• 24 VDC Sounder base power connection supervised internally
by each sounder base. No external power supervision relays
required
• UUKL Listed for smoke control
8830213 - REV A • 10/22 PAGE 2 OF 2
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
PAD300-LFSB
Addressable Low Frequency Sounder Base
Model Description Stock No.
PAD300-LFSB Addressable Low Frequency Sounder Base 3992786
Ordering Information
Detector Base Mounting
PAD300-LFSB can be mounted directly on an electrical box. The
mounting holes are congured for a single gang, 3-1/2” octagon,
3-1/2” square, double gang, 4” octagon, 4” square, 50mm c/c, 60mm
c/c and 70mm c/c boxes. See Fig. 1.
Mount the detector
bracket to the back box
using the mounting
screws.
Alignment Features
Fig. 1
Fig. 2
Fig. 3
Detector Base Wiring
The SLC supports NFPA wiring Class B, A and X. (See device
installation sheet for wiring details). The device also requires 24VDC
power. 12 to 18 AWG conductors can be used.
Fig 4:
Insert small screwdriver
into slot to remove
detector from base.
Using the included screw,
attach the detector base to
detector bracket.
Break o tab (gray area)
in image to enable
locking feature.
Mounting Screws

Other Potter Marine Equipment manuals

Potter PAD300-SB User manual

Potter

Potter PAD300-SB User manual

Potter PE-LFHN Series User manual

Potter

Potter PE-LFHN Series User manual

Potter PAD100-SB User manual

Potter

Potter PAD100-SB User manual

Potter PAD100-SB User manual

Potter

Potter PAD100-SB User manual

Popular Marine Equipment manuals by other brands

GST I-9404 installation instructions

GST

GST I-9404 installation instructions

Katadyn PowerSurvivor 40 installation instructions

Katadyn

Katadyn PowerSurvivor 40 installation instructions

WinGD X62DF-S2.0 installation manual

WinGD

WinGD X62DF-S2.0 installation manual

Raymarine E-Series installation instructions

Raymarine

Raymarine E-Series installation instructions

Raymarine ST7000 Operation manual

Raymarine

Raymarine ST7000 Operation manual

Dometic Passport I/O Legacy Installation and operation manual

Dometic

Dometic Passport I/O Legacy Installation and operation manual

Interphase 20/20 Operation manual

Interphase

Interphase 20/20 Operation manual

TMQ AP55 Display Head Operation and installation

TMQ

TMQ AP55 Display Head Operation and installation

Raymarine RL70C Owner's handbook

Raymarine

Raymarine RL70C Owner's handbook

FITCH Green Fuel Catalyst FHD-70 installation manual

FITCH

FITCH Green Fuel Catalyst FHD-70 installation manual

Fusion Apollo MS-RA770 Guide

Fusion

Fusion Apollo MS-RA770 Guide

Harken T2 Loop 2148 quick start guide

Harken

Harken T2 Loop 2148 quick start guide

Mercury MercMonitor manual

Mercury

Mercury MercMonitor manual

NexSens CB-250 Data Buoy user guide

NexSens

NexSens CB-250 Data Buoy user guide

Simrad AP48 Quick guides

Simrad

Simrad AP48 Quick guides

Toslon TF750 Duo Operation manual

Toslon

Toslon TF750 Duo Operation manual

LEGRAND 0 419 21 Horizontal-mounting installation

LEGRAND

LEGRAND 0 419 21 Horizontal-mounting installation

Harken 391 Installation sheet

Harken

Harken 391 Installation sheet

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.