manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Potter
  6. •
  7. Marine Equipment
  8. •
  9. Potter PAD300-SB User manual

Potter PAD300-SB User manual

Other Potter Marine Equipment manuals

Potter PE-LFHN Series User manual

Potter

Potter PE-LFHN Series User manual

Potter PAD100-SB User manual

Potter

Potter PAD100-SB User manual

Potter PAD300-LFSB User manual

Potter

Potter PAD300-LFSB User manual

Potter PAD100-SB User manual

Potter

Potter PAD100-SB User manual

Popular Marine Equipment manuals by other brands

POWERWINCH 825 Operation manual

POWERWINCH

POWERWINCH 825 Operation manual

JRC JLN-628 brochure

JRC

JRC JLN-628 brochure

DIGITAL YACHT PilotLink2 Product handbook

DIGITAL YACHT

DIGITAL YACHT PilotLink2 Product handbook

Clarion CMS2 Owner's manual & installation manual

Clarion

Clarion CMS2 Owner's manual & installation manual

EBS M7000 installation manual

EBS

EBS M7000 installation manual

Kongsberg M3 Bathy installation manual

Kongsberg

Kongsberg M3 Bathy installation manual

NPK SCS-1002 operating manual

NPK

NPK SCS-1002 operating manual

Furuno FE-800 installation manual

Furuno

Furuno FE-800 installation manual

Harken 1561 instructions

Harken

Harken 1561 instructions

Simrad DD15 manual

Simrad

Simrad DD15 manual

Notifier FS-BSO Installation and maintenance instructions

Notifier

Notifier FS-BSO Installation and maintenance instructions

Raymarine ST40 Quick reference guide

Raymarine

Raymarine ST40 Quick reference guide

Raymarine Maxiview ST80 Owner's handbook

Raymarine

Raymarine Maxiview ST80 Owner's handbook

E2S E2XS112UL Instructions/service manual

E2S

E2S E2XS112UL Instructions/service manual

GUIDANCE MARINE 20- Series Installer's guide

GUIDANCE MARINE

GUIDANCE MARINE 20- Series Installer's guide

R2Sonic 2026 Operation manual

R2Sonic

R2Sonic 2026 Operation manual

COBHAM SAILOR 6000 installation manual

COBHAM

COBHAM SAILOR 6000 installation manual

Raymarine ST60 Tridata Owner's handbook

Raymarine

Raymarine ST60 Tridata Owner's handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

PAD300-SB
Addressable Sounder Base
8830221 - REV A • 10/22 PAGE 1 OF 2
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
Description
The Addressable Sounder Base 6” (PAD300-SB) is a sounder base that
may be utilized in a variety of applications. The base has a locking
feature for the detector that may be used or removed in the eld. Once
the detector is removed, the sounder is accessible in the bottom of the
unit.
The base has an independent sounder module that may be programmed
as a single station, zone or all call sounder. The PAD300-SB passes
through the sound pattern sent to the sounder, therefore it may
reproduce in any pattern the power supply provides.
The panel will support any combination of detectors or modules on
the SLC. The PAD300-SB does not consume an address on the loop
and is fully programmable to operate with any input. Once activated
the sounder will also follow the input from the power source and de-
activate accordingly.
Technical Specications
SLC Voltage 24 VDC
SLC Standby Current 300 μA
PWR Voltage 16- 33 VDC
PWR Active Current 42mA
Alarm LED Current 1.4 mA
Sound Pressure 75dB @ 10ft per UL464
85dB @ 10ft per UL268
Installation Temperature Range 32 to 150°F (0°C to 66°C)
Operating Humidity Range < 93% (Non-condensing)
Dimension 6.4 in (163 mm)
Weight 199 g (7.40 oz)
Height 1.57 in (40 mm)
Features
• Integrated Sounder in base
• UL464 and UL268 Listed
• Sounder independent of detector, allows for a single station,
grouped or all-call
• May be mapped to any device connected to the control panel
• Terminals accept 22 to 12 AWG wire sizes
• Supports Class A, Class X and Class B wiring
• Does not require SLC Loop address
• UUKL Listed for Smoke Control
8830221 - REV A • 10/22 PAGE 2 OF 2
Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 800-325-3936 • www.pottersignal.com
PAD300-SB
Addressable Sounder Base
Model Description Stock No.
PAD300-SB Addressable Sounder Base 3992785
Ordering Information
Detector Base Mounting
Locking Feature
PAD300-SB should be mounted directly on the electrical box. The
mounting holes are congured for a single gang, 3-1/2” octagon,
3-1/2” square, double gang, 4” octagon, 4” square, 50mm c/c, 60mm
c/c and 70mm c/c boxes. See Fig. 1
Eliminate the Locking Feature
PAD300-SB include a locking feature that prevents removal of the
detector and removal of the base cover without using a tool.
1. To enable this feature, break o the locking tab and then install the
detector. See Fig. 2.
Removing of Detector Head from Base
2. To remove the detector from the base once the locking feature has
been activated, insert a small screwdriver into the slot on the base to
push the plastic tab while simultaneously turning the detector head
counter-clockwise. See Fig. 3.
3. To remove the base cover from the lower enclosure once the locking
feature has been activated, insert a small screwdriver into the slot
on the base to push the plastic tab while simultaneously turning the
detector head counter-clockwise.
Using the included screw,
attach the detector base to
detector bracket.
Mount the detector
bracket to the back box
using the mounting
screws.
Break o tab (gray area)
in image to enable locking
feature.
Insert small screwdriver
into slot to remove
detector from base.
Alignment Features
Fig. 1
Fig. 2
Fig. 3
Mounting Screws