3006 P3.GPRS
Document Number: MAN0006 Issue: 6 Page 2 of 6
Dual Serial & IO
Interface
Antenna sma
Connector
Doors
Enterprise
LINK indicator
P3 DATA packet
indicator
SIM
Socket
Power indicator
Mobile Network
Registration indicator SIM connected
indicator
Power & Keyboard
Connector
GPRS End
P3 End
Pin 1
Lock
Unlock
SIM
Selecting a SIM and service provider. Key requirements are that the SIM should have a fixed and public
IP Address. If a PIN is enabled on the SIM make sure it is “0000”. The provider should supply SIM,
Telephone number, IP Address, apn name, apn login and apn password.
Some SIM Providers:
Eseye: http://www.eseye.com, enquiries @ eseye.com, Telephone: +44 (0) 1483 685200
W
i
relesslogic:
http://www.wirelesslogic.com, [email protected]Telephone: +44(0) 844 8044 111 LED’s
PWR lights when power is connected to the P3.GPRS Modem Equipment (ME).
SIM lights to indicate that the SIM is connected and working.
REG Indicates network registration status. Flashes quickly while connecting and slowly once registered.
DATA Flashes to indicate a P3 Data packet or AT command.
LINK Indicate status of communication with Doors Enterprise. The LED will be extinguished during the
Boot and Connecting phase. Once a UDP port is open and the device is waiting for the first packet from
the server it will flash quickly. Once a P3 data packet is detected it will stay lit. If packets are not seen for
20 seconds it will start to flash again. If no packets are seen in the next two minutes the modem will go
through a complete reset sequence tore establish communication.
Antenna
Feed the antenna “SMA” connector through the nearest cable entry point and screw on to the
antenna connection of the GPRS modem. Locate the whip end at the highest point that gives
the best signal. The signal strength is given as a number from 0 to 31 (0 = -113dB or less and
31 = -51dB or greater). Look for a reading of at least 10 for reliable operation.
Doors Enterprise Settings
Connector set to LAN / UDP
GPRS IP address added to the controller