1Main Components
Fig. 1.1
1 –Keypad
2 –Turning handle
3 –Green LED [G]
4 –Red LED [R]
5 –Plastic cover for emergency power
2Definitions
2.1 Master Code [PIN1]
A set of numbers (from 6 to 8 digits) which
opens the lock and allows to operate the settings.
Before using the safe, please change the
factory Master code (see par.4.1). It is strongly
recommended to keep the master code safe
from unauthorized people.
No easily guessed numbers (birthdays, house
and phone numbers, etc.) or simple codes (1, 2,
3, 4, 5, 6) shall be chosen for the code.
Factory Master Code:
1–2–3–4–5–6
2.2 User Code [PIN2]
A set of numbers from 6 to 8 digits which opens
the lock and has limited functions to change the
settings.
The lock with the default factory settings does
not have the User code. Please see par.4.2 to
set the User code.
2.3 Signals
[G]1Short single acoustic signal with single
green LED flash (3) –confirmation of the button
pressing on the keypad.
[G]2Short double acoustic signal with double
green LED flash (3) –confirmation of successfully
finished operation.
[R]-- Long single acoustic signal with single
red LED flash (4) –error message on the user’s
actions.
[R]5Short acoustic signal sounds 5 times with
5 red LED flashes (4) –low battery message. Please
see par.7.1 how to change the battery.
3Main Functions
3.1 Opening the Lock
3.1.1 Opening with the Factory Master code
[ON][1][2][3][4][5][6][Enter]
3.1.2 Opening with the Master Code
[ON][PIN1][Enter]
3.1.3 Opening with the User Code
[ON][PIN2][Enter]
If the code is right, there will be a green LED
flash and it will be possible to open the door within 5
seconds by turning the handle (2) clockwise.
If you enter a wrong code three times in a row,
the lock will be blocked for 5 minutes. This will
be indicated via periodical red LED flashes.
3.2 Closing the Lock
Close the door and turn the handle (2) anti-
clockwise until it stops.
4Service Functions
It is strongly recommended to change the
settings of the lock with the door opened.
After code changing, the lock shall be tested
several times with the secure storage unit’s
door in open state.
The service functions will be unavailable in case
of low power supply which is indicated by the
signals, please refer to par.2.3, [R]5.
4.1 Changing the Master Code [PIN1]
[ON] [Enter] [1] [Enter] [PIN1] [Enter]
[new PIN1][Enter][repeat new PIN1][Enter]
Checking the new Master code:
[ON][new PIN1][Enter]
Safe Digital Lock PS550/E33 USER MANUAL
www.promet-safe.com
Ver. 1/1 от 22.06.2017г.
4.2 Changing the User Code [PIN2] with the
Master Code [PIN1]
Before changing the User Code [PIN2] default
factory setting of Master code [PIN1] has to be
changed (see par.4.1).
[ON][Enter][2][Enter]
[1-9 (user number)][Enter][PIN1][Enter]
[new PIN2][Enter]
[repeat new PIN2] [Enter]
Checking the new User Code:
[ON][new PIN2][Enter]
4.3 Changing the User Code [PIN2] without the
Master Code
[ON][Enter][3][Enter]
[1-9 (user number)][Enter][PIN2][Enter]
[new PIN2][Enter]
[repeat new PIN2] [Enter]
Checking the new User Code:
[ON][new PIN2][Enter]
4.4 Deleting the User Code
[ON][Enter][0][Enter][1-9 (user number)]
[Enter][PIN1][Enter]
4.5 Switching off/switching on the sound
[ON][Enter][5][Enter][PIN1][Enter]
5Time Delay Function
5.1 Switching on the Time Delay function
[ON] [Enter] [6] [Enter] [PIN1] [Enter]
[01-99 –delay time] [1-9 –time for
opening] [Enter]
E.g..: 092 –9 minutes is the delay time, 2
minutes is the time for opening
5.2 Opening the Lock with the Time Delay
[ON] [PIN1 or PIN2] [Enter](Waiting Delay
Time. Acoustic signal will inform about
the end.)[PIN1 or PIN2] [Enter]
Pressing [Enter] during Time Delay leads to an
interruption. Operation has tobe started again.
5.3 Switching off the Time Delay function
[ON] [Enter] [6] [Enter] [PIN1] [Enter]
[000] [Enter]
6Dual Code Function
6.1 Switching on the Dual Code function
Before switching on the function, make sure you
have assigned a User Code [PIN2] see par.4.2.
[ON] [Enter] [7] [Enter] [1-9 (user
number)] [Enter] [PIN1] [Enter]
6.2 Opening with the Dual Code function
[ON][PIN1][Enter]
[PIN2][Enter] –in 1 minute
If the time delay is set, you have to wait the set
delay time before entering PIN2.
You have 60 seconds to enter PIN2
independently of time of opening you have
entered before (see par.5.1)
6.3 Switching off the Dual Code function
[ON] [Enter] [8] [Enter] [PIN1] [Enter]
7Servicing
7.1 Changing the Battery
The battery is located on the inner side of the
door.
Battery box and its location depends on the safe
model
Take out the cover of the battery compartment,
change battery with a new one (9V, type 6LF22).
Place the cover or the box back into their location.
7.2 Opening the lock when the Battery is Flat
Take a new battery (9V, type 6LF22).
Take out the plastic cover for emergency power
(5), see Fig.7.1.
Fig. 7.1
Press the new battery to emergency power pins
and fix it in this position (see Fig. 7.2).
Do not touch the battery’s contacts to the metal
parts of the lock in order to prevent possible
discharging of the battery.
Fig. 7.2
Enter the valid code on the keypad (1).
Disconnect the emergency battery, open the door
and change the flat battery, see par.7.1.

Other Promet Lock manuals

Promet PLS-2.2 User manual

Promet

Promet PLS-2.2 User manual

Promet PLS-3 User manual

Promet

Promet PLS-3 User manual

Promet PS600/E36 User manual

Promet

Promet PS600/E36 User manual

Promet PS300/E31 User manual

Promet

Promet PS300/E31 User manual

Promet PS610/E05 User manual

Promet

Promet PS610/E05 User manual

Promet PLS-3.2 User manual

Promet

Promet PLS-3.2 User manual

Promet PS310/E01 User manual

Promet

Promet PS310/E01 User manual

Promet PS650/E33 User manual

Promet

Promet PS650/E33 User manual

Promet PS600/E05 User manual

Promet

Promet PS600/E05 User manual

Promet PS300/ES01 User manual

Promet

Promet PS300/ES01 User manual

Promet PS600/E31 User manual

Promet

Promet PS600/E31 User manual

Promet PS310/E31 User manual

Promet

Promet PS310/E31 User manual

Promet PS610/E36 User manual

Promet

Promet PS610/E36 User manual

Popular Lock manuals by other brands

ESSEN A210 Series user manual

ESSEN

ESSEN A210 Series user manual

Wittkopp Primor 2600 Installer manual

Wittkopp

Wittkopp Primor 2600 Installer manual

Andersen 400 Series Change guide

Andersen

Andersen 400 Series Change guide

Schlage CO-100 installation instructions

Schlage

Schlage CO-100 installation instructions

Kwikset Kevo Faq

Kwikset

Kwikset Kevo Faq

Yale Assure Lock Lever Touchscreen YRL226 Installation and programming instructions

Yale

Yale Assure Lock Lever Touchscreen YRL226 Installation and programming instructions

Abus Touch 56/50 manual

Abus

Abus Touch 56/50 manual

Dormakaba STV 2 Series Mounting instructions

Dormakaba

Dormakaba STV 2 Series Mounting instructions

Schlage BE499WB user manual

Schlage

Schlage BE499WB user manual

BSi MT6900 Series installation instructions

BSi

BSi MT6900 Series installation instructions

nvent CADDY Speed Link SLS Series Technical handbook

nvent

nvent CADDY Speed Link SLS Series Technical handbook

Mottura Xmode M 2.0 installation instructions

Mottura

Mottura Xmode M 2.0 installation instructions

Ideal Security Decibel SL1000 instructions

Ideal Security

Ideal Security Decibel SL1000 instructions

Motormate Yamaha 10-301 installation instructions

Motormate

Motormate Yamaha 10-301 installation instructions

Gerda TYTAN ZK Fitting instructions

Gerda

Gerda TYTAN ZK Fitting instructions

Clavis SECU S1000 Mounting instructions

Clavis

Clavis SECU S1000 Mounting instructions

DOM RONIS CoverK Assembly

DOM

DOM RONIS CoverK Assembly

GTO R1200 Installation overview

GTO

GTO R1200 Installation overview

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.