PROMIX SHERIFF-9.1 User manual

30.08.2017
SHERIFF-9.1
ELECTROMAGNETIC LOCK
OPERATING MANUAL
TU 3428 – 003 – 80210527 – 14
1. APPLICATION
Electromagnetic lock "Sheriff-9.1" is applied universally. Due to its miniature sizes, the
lock may be used to restrict access to:
- cell lockers, built-in cupboards, file cabinets, etc.;
- refrigerated cabinets, chests, cigarette cabinets and other retail furniture;
- cabinets for storing medicines and chemicals;
- ATM, self-service terminals, vending machines;
- electrical cabinets and control cabinets, process equipment;
- elevators, gateways, etc.
The lock may be open when then the power supply is on, by the controllers of access control
systems, audio and video door phones, code access panels, regular push button or switch.
2. OPERATING CONDITIONS
Climatic operating conditions:
- ambient air temperature: see Para. 4;
- relative air humidity not more than 95% at +35°Сand with lower temperatures without
condensation and frost formation;
- installing indoors and outdoors in the place protected from the direct moisture ingress, dust
and dirt into the lock;
- resistance to the environmental exposure complies with GOST 15150-69:UHL2.
3. DELIVERY SET
1 –Electromagnetic lock 1 pc.
2 – Deadbolt 1 pc.
3 – Screw 3,5х16 4 pcs.
4 – Operating manual 1 pc.
Check completeness of the delivery set while purchasing.
Subsequently, the company-manufacturer does not accept
any claims over completeness of the delivery set.
Production date:
Design: basic
-01 -02 -03 -04
2
4. TECHNICAL SPECIFICATIONS
Design Operating position DC voltage supply, V Current consumption, А
basic
(serial) ↔(horizontally)
↕(vertically) 10÷14 0.65
(12V)
-01* ↔(horizontally)
↕(vertically, armature plate up) 11÷14 0.28
(12V)
-02* ↔(horizontally)
↕(vertically, armature plate down) 11÷14 0.28
(12V)
-03* ↔(horizontally)
↕(vertically, armature plate up) 22÷26 0.24
(24V)
-04* ↔(horizontally)
↕(vertically, armature plate down) 22÷26 0.24
(24V)
Design
Ambient air temperature
T
amb.
, °СVoltage supply pulse
duration T
pd
, sec A pause between voltage
supply pulses, sec
basic
(serial) from -40 to +35 0.5÷60 6xT
pd
(at least)
from +35 to +50 10xT
pd
(at least)
-01* from -40 to +35 not regulated
from +35 to +50 0.5÷120
0.5хT
pd
(at least)
-02* from -40 to +35 not regulated
from +35 to +50 0.5÷120 0.5хT
pd
(at least)
-03* from -40 to +30 not regulated
from +30 to +50 0.5÷120
0.5хT
pd
(at least)
-04* from -40 to +30 not regulated
from +30 to +50 0.5÷120
0.5хT
pd
(at least)
*on request
5. DESIGN AND OPERATING PRINCIPLE
3
When the door is closing, the deadbolt presses the armature plate and is locked by the
armature plate in the cavity. When the voltage supply pulse is applied, the armature plate moves
to the opposite side and comes out from the deadbolt cavity, releasing the deadbolt.
Electromagnetic lock "Sheriff-9.1" has an emergency opening device, it is the nylon line
assembled with the lock. For emergency opening it is necessary to pull the line - the armature
plate is drawn into the lock case.
6. INSTALLATION AND WIRING
ATENTION!!! The possibility to use this lock and the place of mounting the lock is
determined by the installer company based on the characteristics of the design and the
method of installation, the level of premise accountability, assignment of access restriction
and other factors (security, CCTV, etc.).
The lock operates when applying and interrupting the voltage supply, and for it is usually
used a controller (control board) or a switch (button). Controller installation is done according
to the technical data sheet.
Attention: operating voltage supply range of the lock, see Para.4.
The polarity of the voltage does not influence the operability of the lock.
Avoid the heightened voltage supply, because the lock can be damaged due to
overheating!
Provide reliable electrical contact. Isolate the connection points to avoid short-circuiting.
7. MAINTENANCE
Maintenance of the lock is performed at least once per two months and includes:
- examination of the lock to check fixation reliability. If it is necessary, tighten up fixing
elements of the lock and the deadbolt.
4
8. MANUFACTURER'S WARRANTY
Engineering & Technical Center PROMIX, LLC guarantees the conformity of the
electromagnetic lock "Sheriff-9.1" to the requirements of applicable TU standards under the
regulations of operation and installation established in this operating manual. The warranty
period is 18 months commencing from the date of acceptance by Quality Control Department.
Within the warranty period, Engineering & Technical Center PROMIX, LLC undertakes
to repair the defective product free of charge. The shipping cost to the place of repair and back
shall be borne by the Buyer.
The warranty shall not cover defects or damages, resulting from:
- improper maintenance by the Buyer;
- using the lock in conditions that do not conform to the operating requirements;
- mechanical damages or disassembly of the lock by the Buyer;
- violation of transportation and storage regulations.
PACKING AND ACCEPTANCE CERTIFICATE
Electromagnetic lock "Sheriff-9.1" with the specified date of manufacture is made and
accepted in accordance with TU 3428–003–80210527–14, obligatory requirements of state
standards and applicable technical documents, found fit for service and packed by Engineering
& Technical Center PROMIX, LLC.
QCD seal
Engineering & Technical Center PROMIX, LLC
Russia, 214030, Smolensk city, Krasninskoye Hwy, 35
Tel. (4812) 619-330
www.itc-promix.ru
Please send us all your comments and suggestions concerning our products via e-mail:
mail@itc-promix.ru.
Thank you in advance!

Other PROMIX Lock manuals

PROMIX SM305 User manual

PROMIX

PROMIX SM305 User manual

PROMIX SM 323 User manual

PROMIX

PROMIX SM 323 User manual

PROMIX Promix-SM306 User manual

PROMIX

PROMIX Promix-SM306 User manual

PROMIX Promix-SM213 User manual

PROMIX

PROMIX Promix-SM213 User manual

PROMIX Promix-SM112 Series User manual

PROMIX

PROMIX Promix-SM112 Series User manual

PROMIX Promix-SM308.10.1 User manual

PROMIX

PROMIX Promix-SM308.10.1 User manual

PROMIX SHERIFF-5 User manual

PROMIX

PROMIX SHERIFF-5 User manual

PROMIX SM101 User manual

PROMIX

PROMIX SM101 User manual

PROMIX SM490 User manual

PROMIX

PROMIX SM490 User manual

PROMIX Promix-SM420 User manual

PROMIX

PROMIX Promix-SM420 User manual

PROMIX Promix-SM102 Series User manual

PROMIX

PROMIX Promix-SM102 Series User manual

PROMIX Promix-SM132 Series User manual

PROMIX

PROMIX Promix-SM132 Series User manual

PROMIX Promix-SM104 Series User manual

PROMIX

PROMIX Promix-SM104 Series User manual

Popular Lock manuals by other brands

Assa Abloy OneSystem N7 Series Quick manual

Assa Abloy

Assa Abloy OneSystem N7 Series Quick manual

Numeris aspire Product guide

Numeris

Numeris aspire Product guide

KFV Genius A installation instructions

KFV

KFV Genius A installation instructions

Secu SELO-B operating instructions

Secu

Secu SELO-B operating instructions

Yakima ACK23476 manual

Yakima

Yakima ACK23476 manual

Kaba Mas AUDITCON 2 Series installation instructions

Kaba Mas

Kaba Mas AUDITCON 2 Series installation instructions

Assa Abloy YALE 4600CK Series installation instructions

Assa Abloy

Assa Abloy YALE 4600CK Series installation instructions

Securikey REVO A quick start guide

Securikey

Securikey REVO A quick start guide

COMPX Stock Locks C425519RL Dimensional drawing

COMPX

COMPX Stock Locks C425519RL Dimensional drawing

Primera 3S-76 -729A TWIN-TECH manual

Primera

Primera 3S-76 -729A TWIN-TECH manual

eGeeTouch GT1000 quick start guide

eGeeTouch

eGeeTouch GT1000 quick start guide

Schlage F-Series installation instructions

Schlage

Schlage F-Series installation instructions

CODELOCKS Pushbutton 500 Series Installation insrtuctions

CODELOCKS

CODELOCKS Pushbutton 500 Series Installation insrtuctions

Gianni Industries 10006S specification

Gianni Industries

Gianni Industries 10006S specification

iglooworks Padlock 2E user guide

iglooworks

iglooworks Padlock 2E user guide

Miles Nelson MN9000 installation instructions

Miles Nelson

Miles Nelson MN9000 installation instructions

Yale 626F Installation instructions and operators manual

Yale

Yale 626F Installation instructions and operators manual

Command access FLP-UL-M-KIT Insert Instructions

Command access

Command access FLP-UL-M-KIT Insert Instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.