PROMIX Promix-SM420 User manual

1
OPERATING MANUAL
Technical Description. Installation Manual. Certificate.
March 12, 2020
1.
PURPOSE
Promix-SM420 series electromechanical rim locks with a pin locking mechanism (hereinafter
referred to as locks) are intended for locking retail space and office furniture which can be
opened remotely by supplying DC power voltage by means of switches (buttons) or controllers of
access monitoring and control systems, audio and video intercoms, code panels or other
devices.
2.
LABELING
The label attached to the lock body contains the
following information:
1. Lock model
2. Nominal supply voltage
3. Nominal consumed current
4. Date of manufacture and QCD mark
5. Identification number
6. Manufacturer’s website
For the list of lock modifications that can be ordered, see cl. 5.2.
1
4
An example of information
layout on the label
ELECTROMECHANICAL LOCK
Manufacturing Engineering Center
12 V
0.1 А
Made in Russia
No.100 001 008
Availability of built-in sensors:
1 –door position sensor
Supply voltage:
0–12 V
Design:
1 –normally closed
5, 6
2, 3

Promix-SM420
2
Check scope of delivery of the product when buying! After buying, the
manufacturer will not accept claims related to incomplete scope of delivery.
3.
SCOPE OF DELIVERY
4.
DESIGN AND PRINCIPLE OF OPERATION
Locks are manufactured with a normally-closed design (hereinafter referred to as NC). NC
lock is in the closed state when no voltage is supplied, and in the open state when power is
supplied to the lock.
When closing the door, the latch enters the lock groove and is fixed once it has overcome the
pin force. When voltage is supplied, the pin will be drawn into the lock housing and the latch will
be unblocked.
The possibility of emergency opening of the lock is provided with the help of the unlocking lever
(see cl. 7.1).
1 –Promix-SM420 lock
1 pc.
2 –Promix-AD.DB.19 latch
1 pc.
3 –Bracket
1 pc.
4 –Lock power supply wire
1 pc.
5 –Self-tapping screw 4.2х30 (countersunk)
4 pcs.
6 –Self-tapping screw 3.5х14 (cup head)
2 pcs.
7 –Operating manual
1 pc.
Fig. 1. Promix-SM.420 Delivery Package
Fig. 2. Promix-AD.DB.19 latch overall and mounting dimensions
2
grooves

Promix-SM420
3
Fig. 4. Promix-SM.420.10 lock overall and mounting dimensions
Fig. 3. Version of latch installation on the bracket from the delivery package.
Overall and mounting dimensions
Fig. 5. Promix-SM.420.10.1 lock overall dimensions (see mounting dimensions on Fig.4)
2
groove
s
Fastening holes 4 pcs.

Promix-SM420
4
5. TECHNICAL DATA
5.1 OPERATING CONDITIONS
The lock operation environment must be explosion-safe, free of current-conducting dust or
gases that cause metal corrosion and destroying insulation of current conductors and electric
elements, free of current-carrying dust or water vapor, and preventing ingress of water, steam,
fuel and lubricants.
Climatic operating conditions: У3.1 as per GOST 15150-69 with extended temperature range:
ambient temperature: -30 to +50 °С;
Relative air humidity: not higher than 98 % at 25 °С or lower temperatures without moisture
condensation and hoar-frost formation;
installation indoors or outdoors excluding ingress of moisture, dust, dirt, etc. inside the lock.
5.2 TECHNICAL DATA
Modification
Promix-SM420.10
Promix-SM420.10.1
Design
normally closed
DC supply voltage U, V
12±2
Current consumed, А
0.15 (at 12V)
Availability of sensors
-
door position sensor
Supply pulse width (max), s
not rated
Minimum pause between
pulses, s
not rated
Lock weight (
max
),
kg
0.08
Latch holding force (
min
),
kg
150
6. INSTALLATION AND CONNECTION
6.1 LOCK AND LATCH MOUNTING
1. Install the latch in the area designedfor installation.
2. Insert the latch into the lock and fix the lock so that the latch entersit until click.
3. Connect the lock (see cl. 6.2) and function test by applying supply voltage. The lock must
unlock the latch. Open the door so that the latch disengages with the lock.
4. If the latch is not unlocked when power is supplied, push the door in the area of lock fixation
and apply voltage. Then adjust the latch length providing for the necessary free play and
alignment.
6.2 CONNECTING PROCEDURE
The lock operation is controlled by supplying and blocking power. For this purpose a controller
(control board) or a switch (button) is generally used. The controller is mounted in accordance
with its certificate.
Connect the lock power wires adhering to the following polarity:

Promix-SM420
5
See operating voltage range in cl. 5.2. Avoid supply of increased voltage.
Ensure a reliable electric contact. To prevent short-circuit, insulate places of
connection.
White –positive pole of the power supply;
Black –negative pole of the power supply;
Reverse voltage supply does not ensure lock operability, but it does not cause its failure.
Example of the lock connection to the remote control system Promix-RDS.
7.
FEATURES OF INSTALLATION AND
OPERATION
1)
The possibility of using the locks for access restriction to retail and office furniture and the
place of installation are determined by
the installation organization
on the basis of the
design features and the mounting method, furniture criticality level, the purpose of the access
restriction regime and other factors (the presence of security providers, video surveillance,
etc.).
2) To prevent door deformation, it isrecommended to install the lockin the area of the handle.
3) When mounting the lock and the latch, it is necessary to ensure their coaxial alignment within
the latch free movement allowance.
4) When the door is closed, the latch must be inserted all the way into the lock. The lock may fail
to open when the door is in “tension” condition, i.e., an external force for opening is applied.
7.1 EMERGENCY OPENING
There is an emergency opening lever
next to the power supply wire output. For
mechanical unlocking of the lock, pull the
lever and then open the door.
Lock
Controller Promix-CR.RX
Promix-CR.TX
RCU
~220 V
Emergency opening lever
Pull

Promix-SM420
6
The lock does not need lubrication!
8.
POTENTIAL MALFUNCTIONS
Malfunctions and problems
Remedies
The lock does not open when supply
voltage is applied.
Check polarity and conformity of the lock supply voltage
to the required value.
Close the door tightly and press on it at the latch
fastening place, and apply voltage to the lock.
After opening of the lock, adjust the latch length.
The lock does not block the latch.
Check the distance between the latch and the lock; if
necessary, increase the latch length.
9.
MAINTENANCE
Maintenance of the lock is performed at least once every two monthsand includes:
Visual inspection of the lock to check the reliability of the fastening. If necessary, tighten
the fasteners of the lock and the latch.
Check the latch length. If the latch bar abuts against the lock and this leads to non-tight
door closing, or if the latch is not fixed by the lock when the door is closed, adjust the latch
length.
10.
STORAGE AND TRANSPORTATION
Prior to putting into operation, the locks must be stored in the manufacturer’s packing, in
rooms with an ambient temperature of -30 to +50 °С and a relative humidity not higher than 98%
at 25 ºС С in compliance with storage conditions as per GOST 15150-69.
Locks transportation conditions must comply with group C as per GOST 23216-78 in terms of
exposure to mechanical factors, and Ж2 as per GOST 15150-69 in terms of exposure to climatic
factors.
11.
SAFETY REQUIREMENTS
The design of the locksensures safety of personnel involved in mounting and maintenance.
Due to low DC supply voltage, the products correspond to class III as per GOST 12.2.007.0-
75 and are electrically safe.
Fire safety of the locks is ensured by use of non-combustible or hardly combustible materials,
and low supply voltage.
12.
DISPOSAL
The product is not hazardous for human life and health or for the environment; disposal after
its service life is performed without taking any special measures for environment protection.
13.
WARRANTY LIABILITIES
The manufacturer, ETC PROMIX LLC, warrants conformity of Promix-SM420 locks to
requirements of current Technical Specifications provided that transportation, storage, installation
and operation rules established in this Manual are followed.

Promix-SM420
7
The operation warranty period is 12 months from the date of sale but not
longer than 18 months from the day of acceptance by the manufacturer’s QCD.
Faulty products are accepted for repair only together with the latch, on the
obligatory condition that factory labels are retained on the product body.
To improve product quality the manufacturing plant reserves the right to make
modifications to the product design without prior notice.
Within the warranty period ETC PROMIX LLC undertakes to repair defective products free of
charge. Expenses for transporting the product to the place of repair and back will be borne by the
Buyer.
Warranty liabilities do not cover any defects and damages caused by:
Improper maintenance by the Buyer;
Use of the product under conditions that do not comply with the operation requirements;
Mechanical damages or disassembly of the products bythe Buyer;
Non-observance of the transportation and storage rules.
On expiration of the warranty service period, the manufacturer provides after-warranty service
on a contractualbasis.
14.
ACCEPTANCE AND PACKING
CERTIFICATE
Promix-SM420 Electromechanical lock
in quantity of ____ pieces (1 pc. by default)
bearing the
manufacturing date and QCD mark on the body, was manufactured and accepted in compliance
with Specifications, obligatory requirements of state standards and current technical
documentation, recognized as fit foroperation and packed by ETC PROMIX LLC.
Engineering and Production Center PROMIX LLC
Russia, 214030, Smolensk, Krasninskoesh., 35, lit. A
Phone: (4812) 619-330
www.promix-center.com
facebook.com/promixcenter
mail@promix-center.com
This manual suits for next models
2
Table of contents
Other PROMIX Lock manuals

PROMIX
PROMIX Promix-SM306 User manual

PROMIX
PROMIX SM305 User manual

PROMIX
PROMIX Promix-SM102 Series User manual

PROMIX
PROMIX Promix-SM112 Series User manual

PROMIX
PROMIX SM490 User manual

PROMIX
PROMIX Promix-SM308.10.1 User manual

PROMIX
PROMIX SHERIFF-9.1 User manual

PROMIX
PROMIX SHERIFF-5 User manual

PROMIX
PROMIX SM101 User manual

PROMIX
PROMIX SM 323 User manual
Popular Lock manuals by other brands

Omlet
Omlet Omlet zippi lock instruction manual

SECO-LARM
SECO-LARM E-941DA-600Q installation manual

Masterlock
Masterlock 4400EURENT user manual

Borglocks
Borglocks BL7000 Easicode instructions

Borglocks
Borglocks BL 2605 MG Pro Parts List, Installation and General Information

Iron logic
Iron logic Z-396 EHT user manual