Contents MVI56-PNPM ♦ControlLogix Platform
Phantom Network Protocol Master Communication Module
ProSoft Technology, Inc. Page 5 of 91
January 2, 2008
Contents
PLEASE READ THIS NOTICE.............................................................................................................................. 2
Warnings ........................................................................................................................................................... 2
Your Feedback Please ...................................................................................................................................... 3
GUIDE TO THE MVI56-PNPM USER MANUAL ................................................................................................... 7
1START HERE ............................................................................................................................................... 9
1.1 System Requirements.............................................................................................................................. 9
1.2 Package Contents ..................................................................................................................................10
1.3 Setting Jumpers......................................................................................................................................11
1.4 Install the Module in the Rack.................................................................................................................12
1.5 Connect your PC to the Processor .........................................................................................................13
1.6 Download the Sample Program to the Processor ...................................................................................14
1.6.1 Configuring RSLinx .......................................................................................................................15
1.7 Connect your PC to the Module..............................................................................................................17
2INSTALLING AND CONFIGURING THE MODULE....................................................................................19
2.1 Modifying the Module Configuration .......................................................................................................23
2.1.1 Power Up ......................................................................................................................................24
2.1.2 Changing Parameters During Operation .......................................................................................24
2.1.3 Module Data Object (PNPModuleDef)...........................................................................................25
2.1.4 User Data Objects.........................................................................................................................28
2.1.5 Slave Polling Control and Status...................................................................................................29
3LADDER LOGIC..........................................................................................................................................30
4DIAGNOSTICS AND TROUBLESHOOTING ..............................................................................................31
4.1 Reading Status Data From the Module...................................................................................................31
4.1.1 The Configuration/Debug Menu ....................................................................................................31
4.1.2 Required Hardware .......................................................................................................................32
4.1.3 Required Software.........................................................................................................................32
4.1.4 Using the Configuration/Debug Port..............................................................................................33
4.1.5 Main Menu ....................................................................................................................................34
4.1.6 Data Analyzer................................................................................................................................37
4.1.7 Data Analyzer Tips........................................................................................................................39
4.1.8 Database View Menu ....................................................................................................................42
4.1.9 Master Command Error List Menu ................................................................................................44
4.1.10 Master Command List Menu .........................................................................................................45
4.2 LED Status Indicators .............................................................................................................................46
4.2.1 Clearing a Fault Condition.............................................................................................................47
4.2.2 Troubleshooting.............................................................................................................................48
5REFERENCE...............................................................................................................................................49
5.1 Product Specifications ............................................................................................................................49
5.1.1 Features and Benefits ...................................................................................................................49
5.1.2 General Specifications ..................................................................................................................49
5.1.3 Functional Specifications...............................................................................................................50
5.1.4 Hardware Specifications................................................................................................................50
5.2 Functional Overview ...............................................................................................................................51
5.2.1 General Concepts .........................................................................................................................51
5.2.2 Main Logic Loop............................................................................................................................51
5.2.3 Backplane Data Transfer...............................................................................................................52
5.2.4 Normal Data Transfer....................................................................................................................53
5.2.5 Configuration Data Transfer ..........................................................................................................55
5.2.6 Master Command Data List...........................................................................................................56
5.2.7 Slave Status Blocks.......................................................................................................................57