YRM2.DIODE
Y-Series 24-60V, 20A, DUAL REDUNDANCY MODULE
Nov 2006 / Rev. 1.0 DS-YRM2.DIODE-EN
All parameters are specified at 24V, 20A output current, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
2/17
INDEX PAGE
INDEX PAGE
1. General Description ............................................1
2. Short-form Data ..................................................1
3. Order Numbers....................................................1
4. Markings..............................................................1
5. Input and Output Characteristics .......................3
6. Power Losses........................................................4
7. Alarm Contacts ....................................................4
8. Functional Diagram.............................................5
9. Front Side and User Elements.............................5
10. Terminals and Wiring..........................................6
11. Reliability.............................................................6
12. EMC......................................................................7
13. Environment........................................................8
14. Protection Features .............................................9
15. Safety ...................................................................9
16. Dielectric Strength ..............................................9
17. Approvals.......................................................... 10
18. Fulfilled Standards............................................ 10
19. Used Substances ............................................... 10
20. Physical Dimensions and Weight ..................... 11
21. Installation and Operation Instructions .......... 11
22. Accessory........................................................... 12
23. Application Notes............................................. 13
23.1. Recommendations for Redundancy ...... 13
23.2. 1+1 Redundancy up to 10A ................... 13
23.3. 1+1 Redundancy up to 20A ................... 14
23.4. N+1 Redundancy, Example with 20A .... 14
23.5. Battery Back-up ...................................... 15
23.6. Redundancy for Sensitive Loads ............ 15
23.7. Decoupling of Buffered Branches ......... 16
23.8. Use in a Tightly Sealed Enclosure .......... 16
23.9. Mounting Orientations.......................... 17
INTENDED USE
The redundancy module shall only be installed and put into operation by qualified personnel.
This redundancy module is designed for installation in an enclosure and is intended for the general use, such as in
industrial control, office, communication, and instrumentation equipment. Do not use this device in aircraft, trains
and nuclear equipment, where malfunctioning of the power supply may cause severe personal injury or threaten
human life.
TERMINOLOGY AND ABREVIATIONS
PE and symbol PE is the abbreviation for Protective Earth and has the same meaning as the symbol .
Earth, Ground This document uses the term “earth” which is the same as the U.S. term “ground”.
T.b.d. To be defined, value or description will follow later.
DC 24V A figure displayed with the AC or DC before the value represents a nominal voltage with
standard tolerances (usually ±20%) included.
E.g.: DC 12V describes a 12V battery disregarding whether it is full (13.7V) or flat (10V)
24Vac A figure with the unit (Vac) at the end is a momentary figure without any additional
tolerances included.
DISCLAIMER
The information presented in this document is believed to be accurate and reliable and may change without notice.