6. Turn the water o and purge the lines.
7. Plumb inlet and outlet pipe work to the Hybrid unit. Both the inlet and outlet are a
25 mm female brass connection.
Warning: Use PTFE thread seal tape on all connections. Use of pipe sealants
will void warranty.
8. Open the swing doors to the unit.
9. Remove the safety cap from the aluminium nut, if the nut is
inadvertently loosened during this process, retighten the nut.
Insert the spring into the ballast by dropping it into the chamber.
Slowly insert UV lamp into chamber through the hole of the
aluminium nut end. Connect the lamp connector to the pins on
the lamp. Do not let go of the lamp until the lamp is connected
to the socket (seeFig.8&9).
Nevertouchthequartz(glass)andlampsurfaceasmarks
orngerprintsmayinterferewithUVtransmission.Iflampis
soiled,pleasecleanlampwithanalcoholbasedcleaner.
10. Put safety cap on the aluminium nut. Connect the ground wire to the chamber. Plug
in power connector.
11. Check the main power cord for the unit is plugged in and the power is on.
12. Check each housing bowl and ensure they have not become loose in transport. Use
the provided spanner to tighten lter bowl until rm. DO NOT OVER TIGHTEN.
13. (Pump Models Only) Check the power cord for the pump is plugged in (power is
o).
14. (Pump Models Only) Ensure that water is reaching the pump, this may require
siphoning the line to begin water ow.
15. (Pump Models Only) Turn on the power to the pump.
16. Turn the water on, let the water ow through – opening a tap downstream to ush
the unit for 1-2 minutes. Then check the system thoroughly for leaks.
Note:Forinitialuse,wait3-5minutestoallowwatertopassthroughthewhole
unit.Turnonadownstreamtaptoletwaterowthroughtheunitfor2-3minutesto
releaseairandimpuritiesfromthesystem.
17. Turn the power to the UV system on and ensure that the lamp is operating. Make
sure that the GREEN LED is illuminated (refer Lamp Replacement Procedure on
pg.14).
18. Close and lock the swing doors. Note: Your cabinet comes with 2 keys for your
convenience. Please store them safely.
Note:Lostormisplacedkeysarenotcoveredbywarranty.
Installation Procedure
12
valve
IN OUT
10
mins
45
78
Replacing UV Lamp
valve
IN
3
Fig. 8
Lamp
Connector