6
GB
THE GAS FIREPLACE IN GENERAL
This RAIS product is a highly efcient gas replace
with a sealed combustion chamber for a balanced ue
system. The replace has variable heating power and is
tted with a burner developed using the latest burner
technology.
BEFORE INSTALLATION
All local regulations and provisions must be studied
before installation. Always check the national building
and gas regulations.
In addition, it should be conrmed that the description
on the information label relating to gas type and gas
pressure is in accordance with the local regulations. The
gas supply should be examined to ensure that it can
supply the required amount of gas and the required
pressure.
It is recommended that gloves are worn when installing
the gas replace to avoid ngerprints on glass, etc.
GAS CONNECTION
This gas replace may only be installed, adjusted, and
serviced by an authorised installer. The installation
must comply with local and national building and gas
regulations, and the instructions in the installation
manual must be followed.
KEEP THE MANUALS
The installation manual and user manual are stored by
the customer for clarication during use and for, e.g.
service.
WARNING!
If you smell gas, immediately switch off the gas supply. Turn off the replace at the stopcock and main switch.
Ventilate the room by opening windows and doors. Do not use electrical appliances or switches in the vicinity of the
replace. The gas supply may not be reconnected until an authorised installer has examined the replace and approved
it.
NOTE!
For LPG, the installed regulator must allow the inlet pressure given on the information label. A licensed gas technician
must size the pipe to ensure the correct gas pressure and ow rate.
INTRODUCTION
Product ID: 2575DM29341
Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
18 2575
Visio Gas 100 RD Visio Gas 100 T (VISIO 9)
0359 C11
C31
C91
Gas category and supply pressure
Input
(Hi, kW)
Output
(Hi, kW)
Burner
pressure high
(Hot) Country of destination
L
P
G
I3+ (28-30/37) G30@28-30
mbar 11,7 9,4
27,2
Interval
24,5 - 29,6
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, PT, SI, SK, TR
I3+ (28-30/37) G31@37 mbar 11,2 8,9 36
32,4 - 39,6
BE, CH, CY, CZ, ES, FR, GB,
GR, IE, IT, PT, SI, SK, TR
I3P (30) G31@30 mbar 9,9 7,9 27,5
24,8 - 30,3 FI, NL, RO
I3P (37) G31@37 mbar 11,2 8.9 36
32,4 - 39,6
BE, CH, CZ, ES, FR, GB, GR,
HR, IE, IT, LT, NL, PL, PT, SL,
SK, TR
I3P (50) G31@50 mbar 11,2 8,9 36
32,4 - 39,6 AT, CH, CZ, DE, NL, SK
I3B/P (30) G30@30 mbar 11,7 9,4 27,2
24,5 - 29,6
BE, BG, CY, DK, EE, FI, FR,
GB, GR, HR, HU, IT, LT, MT,
NL, NO, RO, SE, SI, SK, TR
I3B/P (30) G31@30 mbar 9,9 7, 9 27,5
24,8 - 30,3
BE, BG, CY, DK, EE, FI, FR,
GB, GR, HR, HU, IT, LT, MT,
NL, NO, RO, SE, SI, SK, TR
I3B/P (50) G30/G31@50 11,2 8,9 36
32,4 - 39,6 AT, CH, CZ, DE, FR, SK
N
A
T
U
R
A
L
G
A
S
I2H/
I2E G20 @ 20 mbar 8,1 6,5
12,5
Interval
11,3 - 13,6
AT, CH, CZ, DE, DK, EE, ES,
FI, GB, GR, HR, IE, IT, LT, LU,
LV, NO, PL, PT, RO, SE, SI,
SK, TR
I2ELL G25 @ 20 mbar 6,5 5,3 12,5
11,3 - 13,6 DE
I2E+ G20@20 mbar 8,1 6,5 12,5
11,3 - 13,6 BE, FR
I2E+ G25@25 mbar 7, 3 5,9 16
14,4 - 17,4 BE, FR
I2L / I2EK / I2
(43.46-45.3 MJ/m3 0c) G25.3 @ 25 mbar 7,4 6,0 16,1
14,5 - 17,5 NL
TOWN GAS
G150.1 @ 8 mbar 6,4 4.8
5
Interval
4,5 - 5,5
DK, SE
G150.1 @ 10 mbar 7,4 5.7 6
5,4 - 6,5 DK, SE
This appliance must be installed in accordance with the rules in force, and only used in a sufficiently ventilated space. Consult
instructions before installation and use of this appliance. Tested and Certified for use on Biopropane. Efficiency class 1.
Serial number Burner ID.
CE Label for: Visio Gas 22-06-2023
INFORMATION LABEL
All RAIS gas replaces have an information label which
states the replace’s gas type, gas pressure, power,
etc.
The information label is laid on top of the gas replace
on delivery. Position the information label with the
GV60 Combination Valve and receiver for easy
access so that the authorised installer can check the
information.
The information label must be used during installation
for setting and checking gas pressure.
There is a larger version of the information label on
page 54.