REED R5015 User manual

reedinstruments
www com
Model
Instruction
Manual
INSTRUMENTS
INSTRUMENTS
True RMSmA Clamp Meter
R5015
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
2
INSTRUMENTS
INSTRUMENTS
Table of Contents
Safety ..........................................................................................................2
Features.......................................................................................................3
Specications.......................................................................................... 3-5
Electrical Symbols.......................................................................................6
Product Description ....................................................................................6
LCD Description ..........................................................................................7
Operating Instructions .......................................................................... 8-11
Battery Replacement.................................................................................11
Safety
The unit complies with CE/ETL certication (EN61010-1, EN61010-2-30,
and EN61010-2-32), CAT II 600V & CAT III 300V overload protection.
Please read the manual carefully before use.
• Wearprotectiveequipmenttoavoiddamagecausedbyarcdischarge
when the live conductor is exposed.
• Beforeeachusechecktheproductcarefullytoensurenodamage.
• Holdtheinstrumentbythehandlewheninuse.
• Beforechangingthebatteryensureunitisnotconnectedtolivewires.
• Donotuseclampmeterinenvironmentsabove600Vor400Hz.
• Paycloseattentionto60VDC,30VACor42VAC(peakvalue)orabove
voltageastheymaycauseelectricshock.
• Cleantheinstrumentwithadampclothandavoidingabrasive
compounds or solvents.
• Incaseofanyabnormality,stopusingthisinstrumentimmediately.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
3
INSTRUMENTS
INSTRUMENTS
Features
• MeasuresAC/DCcurrent/voltage,resistanceandcapacitance
• Highresolution0.1mA(AC)and1mA(DC)
• TrueRMSforACcurrent/voltage
• 6000-countbacklitLCDdisplay
• Built-innon-contactvoltagedetectorwithLEDindicator
• V.F.C(variablefrequencycontrol)modeforair-conditionermaintenance
and diagnostics
• Lowbatteryandoverrangeindicators
• Diodetestandcontinuitycheckfunctions
• Durabledoublemoldedplastichousing
• Cat.II600V&CATIII300Vsafetyrating
• Autoshut-off
• Includestestleads,batteriesandcarryingcase
Specifications
AC/DC Current
Range AC: 600mA, 6000mA, 60A / V.F.C
600mA-60A
DC: 6000mA, 60A
Accuracy AC(@50/60Hz):600mA
±(1.5% rdg. +10 dgt.)
6000mA±(2.5% rdg. +5 dgt.)
60A±(2% rdg. +5 dgt.)
V.F.C±(4%rdg.+10dgt.)
DC: 6000mA±(2% rdg. +5 dgt.)
60A±(2% rdg. +3 dgt.)
Resolution AC: 0.1mA, 1mA, 0.01A / 0.1mA, 0.01A
DC: 1mA, 0.01A
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
4
INSTRUMENTS
INSTRUMENTS
AC/DC Voltage
Range AC: 6, 60, 600V / V.F.C 200-600V
DC: 600mV, 6, 60, 600V
Accuracy AC: ±(0.8% rdg. +3 dgt.) /
±(4.0%rdg.+3dgt.)
DC: 600mV ±(0.7% rdg. +5 dgt.)
±(0.7% rdg. +3 dgt.)
Resolution AC: 1mV, 10mV, 0.1V, 1V / 0.1V
DC: 10µV, 1mV, 10mV, 0.1V
Resistance
Range 600Ω,6kΩ,60kΩ,600kΩ,6MΩ,60MΩ
Accuracy 600Ω: ±(1% rdg. +2 dgt.)
6/60/600kΩ:±(0.8%rdg.+2dgt.)
6MΩ:±(1.2%rdg.+3dgt.)
60MΩ:±(1.5%rdg.+5dgt.)
Resolution 1pF, 10pF, 100pF, 1nF, 10nF, 100nF,
1μF, 10μF
Capacitance
Range 6.2nF, 62nF, 620nF, 6.2μF, 62μF,
620μF,6.2mF,62mF
Accuracy 6.200nF±(4%+10)
62.00nF~620.0μF±(4%+5)
6.200mF~ 62.00mF ±10%
Resolution 1pF, 10pF, 0.1µF, 1µF, 10µF
General Specications
Range Selection Autoranging
TrueRMS Yes
Display 6,000 count LCD display
DisplayHold Yes
Zero Push
ButtonAdjustment Yes
DiodeTest Yes
BacklitDisplay Yes
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
5
INSTRUMENTS
INSTRUMENTS
OverrangeIndicator Yes
ContinuityCheck Audiblesignalifresistance<10Ω
Non-Contact
VoltageDetector Yes
Autoshutoff Yes(after15mins)
Power Supply 2 AAA Batteries
LowBatteryIndicator Yes
Jaw Opening 0.67” (17mm)
Overvoltage Category CAT. II 600V, CAT. III 300V
ProductCertications CE,ETL,RoHS
OperatingTemperature 32to104°F(0to40°C)
StorageTemperature 14to122°F(-10to50°C)
Dimensions 6.9x2.4x1.3”(175x60x33.5mm)
Weight 6oz(170g)
Overload protection: 100A
•Accuracyguaranteescale:5~100%ofmeasuringrange,<20digit
residual reading is allowed for 600mA open circuit.
•ACcrestfactormayreach3.0at4,000counts;fornon-sinusoidal
waveform, the error of crest factor increases with the following formula:
a. Add 3% when the crest factor is 1~2
b. Add 5% when the crest factor is 2~2.5
c. Add 7% when the crest factor is 2.5~3
Overload protection: 600V-PTC
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
6
INSTRUMENTS
INSTRUMENTS
Electrical Symbols
Product Description
1. Clamp Jaws
2. Clamp Trigger (Press the
trigger to open the clamp)
3. Non Contact Voltage Indicator
4. FunctionButton(Changefrom
ACV/DCV/Hz,Resistance
Ω/Diode/Capacity, Current
ACA/DCA, NCV, Off)
5. HOLD/BacklightButton(To
keepthecurrentmeasurement
onthescreen/Holdbuttonfor
2secondsforbacklightto
turn on)
6. ZERO Button (Return DCA to
zero,measuretherelative
value of capacity & voltage)
7. SELECT Button
8. LCD Display
9. InputJack/COMInputJack
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
7
INSTRUMENTS
INSTRUMENTS
LCD Description
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
8
INSTRUMENTS
INSTRUMENTS
Operating Instructions
Measuring AC/DC voltage/HZ
1. SelectACvoltageandHzorDCvoltage.
2. Inserttheredprobeintheredjack(positiveterminal)andblack
probeintheblackjack(COMterminal).
3. Touchtheredandblackprobetoitemundertest.
4. ThevaluewillappearontheLCD.
Note: Do not exceed 600V (AC/DC)
as there is a risk of electric shock
and potential damage to the
instrument that may occur.
Measure Resistance/Diode/Circuit On/Off/Capacity
•Inserttheredprobeintheredjack(positiveterminal)andblackprobein
theblackjack(COMterminal).
•Connecttheprobeinparallelwiththetestedcomponenttomeasure.
•ThevaluewillappearontheLCD.
Note: When measuring the
voltage/capacity/diode range, do
not exceed DC 60 V or AC 30V to
avoid personal injury.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
9
INSTRUMENTS
INSTRUMENTS
Measuring AC/DC Current
AC current
•SelectyourdesiredrangeforACcurrent(600mA~,6,000mA~,60A~).
Opentheclampheadandattachthewireonthehook.Ensurethatthe
hooksarermlyclosed.ValuewilldisplayontheLCD.
DC current
•PresstheSELECTbuttonandenterintheDCcurrentrange(6,000mA,
60A).PresstheZERObuttontobringthereadingbacktozero.Press
itmultipletimesifpressingitoncedoesn’twork.Opentheclamp
headandattachthewireonthehook.Ensurethatthehooksarermly
closed. Value will display on the LCD.
NOTE: Pull out the testing probe
to avoid electric shock.
The clamp should be in the same
direction as the measured object
in process of zeroing obtain
accurate reading because of
the product’s high sensitivity.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
10
INSTRUMENTS
INSTRUMENTS
Measuring Non-Contact Field Measurement
To measure the detected AV voltage or magnetic eld close the clamp
aroundtheobjecttodetectthemotion.Theanalogquantityis“EF”when
itis≤criticalvoltageandwilldisplayas“———“,differentvariationsof
buzzingwilldistinguishtheintensityofdetectedeld.
Note: When the unit is in NVC
measurement mode, pull out
the testing probe to avoid
electric shock.
Backlight
PresstheHOLDbuttonfor2secondstoturnontheLCDbacklight.
Automatically Turns Off
If the unit is left unused for 15 minutes it will automatically turn off to
save power. Press the SELECT button in shutdown mode to power it
on.Thebuzzerwillmake5soundspromptingthecancellationofthe
auto off function. Turn it off and then restart, the auto off function will be
recovered.Thebuzzerwillsend5continuousalarmingsounds,andthen1
longalarmingsoundbeforetheproductautomaticallyshutsdown.When
the auto off function is canceled, it will send 5 alarming sounds every 15
minutes.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
11
INSTRUMENTS
INSTRUMENTS
Functions
Whenpressinganyfunctionbuttonorturninganyswitchthebuzzer
willmakea“beep”noise.Whenthemeasuringvoltageorcurrentthe
buzzerwillalsosendacontinuous“beep”intermittentsoundtowarm
the outrange. The functions are: AC/DC voltage >about 600V, mA AC/DC
current >620mA (or 6200mA), A AC/DC large current >62A.
Battery Replacement
1. Ensure the power switch is set
to“OFF”andpulltheprobe
outofinputjack.
2. Remove the battery cover with
a screwdriver.
3. Install two new AAA batteries.
4. Replacethecoverandscrew
in the battery cover.
For service on this or any other REED product or information on other
REED products, contact REED Instruments at info@reedinstruments.com.
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com

reedinstruments
www com
12
INSTRUMENTS
INSTRUMENTS
Notes _________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
________________________________________________
www.GlobalTestSupply.com
Find Quality Products Online at: sales@GlobalTestSupply.com
Table of contents
Other REED Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Spectrum
Spectrum FieldScout pH 600 Meter quick start guide

Koehler
Koehler K2269X Operation and instruction manual

ESD SYSTEMS
ESD SYSTEMS 41116 Operation installation and maintenance

Fiery
Fiery EFI ES-3000 Setup guide

Bacharach
Bacharach HGM-MZ Maintenance and troubleshooting guide

Ripley
Ripley ODM DLS 360 quick start guide