Note
It must be possible to disconnect the device from the mains at any time.
ÎInstall the mains plug such that it is accessible at any time.
ÎIf this is not possible, install a switch that can be accessed.
Do not use the device if it is visibly damaged!
The power supply of the device must be 100… 240V~ (50 … 60 Hz).Attach flexible
cables to the housing with the enclosed strain relief and the corresponding screws.
The controller is equipped with 2 semiconductor relays to which loads such as
pumps, valves, etc. can be connected:
Relay 1
18 = Conductor R1
17 = Neutral conductor N
13 = Protective earth conductor ⏚
Relay 2
16 = Conductor R2
15 = Neutral conductor N
14 = Protective earth conductor ⏚
The mains connection is at the following terminals:
19 = Neutral conductor N
20 = Conductor L
12 = Protective earth conductor ⏚
Connect the temperature sensors (S1 to S4) to the corresponding terminals
with either polarity:
1 / 2 = Sensor 1 (e. g. collector sensor 1)
3 / 4 = Sensor 2 (e. g. store sensor 1)
5 / 6 = Sensor 3 (e. g. store sensor top)
7 / 8 = Sensor 4 (e. g. return sensor)
fuse
VBus®mains
terminals
load terminals
sensor terminals protective earth
conductor terminal
1 (1) A 240 V~
1 (1) A 240 V~
R1
R2
LN
R1
N
2019
18
171615
14131212
NR2
IP 20
T2A
100 ... 240 V~
50-60 Hz
Temp. Sensor Pt1000
S2S1 S3 S4 VBus
PWM 2
PWM 1
VFD
Made in Germany
DeltaSol®CS Plus bidirektional
345678910
2.3 VFD Grundfos Direct Sensor™
The controller is equipped with 1 input for a digital VFD Grundfos Direct Sensor™
for measuring the flow rate and the temperature. Connection is made at the VFD
terminal (bottom left).
2.4 PWM interfaces
Speed control of a HE pump is possible via a PWM signal.The pump has to be con-
nected to the relay as well as to one of the PWM outputs of the controller. Power
is supplied to the HE pump by switching the corresponding relay on or off.
The terminals marked PWM 1 and 2 are interfaces for bidirectional HE pumps.
2 4
1 3
1 (1) A 240 V~
1 (1) A 240 V~
R1
R2
LN
R1
N
2019
18
17161514131212
NR2
IP 20
T2A
100 ... 240 V~
50-60 Hz
Temp. Sensor Pt1000
S2S1 S3 S4 VBus
PWM 2
PWM 1
VFD
Made in Germany
DeltaSol®CS Plus bidirektional
345678910
PWM1:
1 = PWM output 1, control signal
2 = PWM output 1, GND
3 = PWM input 1, feedback signal
4 = not assigned
PWM2:
1 = PWM output 2, control signal
2 = PWM output 2, GND
3 = PWM input 2, feedback signal
4 = not assigned
2.5 Data communication / Bus
The controller is equipped with the RESOL VBus®for data transfer and energy
supply to external modules. The connection is to be carried out at the terminals
marked VBus (either polarity).
One or more RESOLVBus®modules can be connected via this data bus, such as:
• DL2 / DL3 Datalogger
• KM1 Communication module
Furthermore, the controller can be connected to a PC or integrated into a network
via the RESOL VBus®/USB or VBus®/LAN interface adapter (not included). Differ-
ent solutions for visualisation and remote parameterisation are available on the
RESOL website www.resol.com.
Note
More accessories on page 69.