Overview
• variable controller for circulation systems
• demand-oriented pump control
• easy-to-install housing
• user-friendly operation
• intuitive menu operation via push buttons
The purpose of a circulation system is to provide the user with hot water as quick
as possible when opening the tap.The pipe line system for supplying with domestic
hot water is simultaneously used as a circulation system so that by means of the
circulating pump, water is passed through the water pipes even without having to
open the tap.
There are different solution possibilities:
• 24 h operation of the circulating pump
• time-controlled operation of the circulating pump
• time and thermally controlled operation of the circulating pump
The solution possibilities mentioned are not optimally adjustable and will cause
unnecessary energy consumption.
Our solution:
Via a ow switch in the hot water pipe, the controller unit controls the water
draw-off.After opening the tap for a brief moment, the circulating pump is switched
on and will be switched off again after the adjusted runtime.The tap functions like
a ”remote control“.This circulating pump control function is an eco-friendly and
energy-saving solution in line with demand.
Technical data
Housing: plastic, PC-ABS and PMMA
Dimensions: 172 x 110 x 46 mm
Protection type: IP 20 / EN 60529
Protection class: II
Ambient temp.: 0 … 40 °C
Display: LCD, multi-functional display, combined display
Controller adjustment: menu-operated
Inputs: 1 sensor input for ow switch
1 General function description
2
34
5
1
EC1
Strömungsschalter
Made in Germany
S1 NR1N L
PRG
12 12 13 14 17
T4A
115 V~
2 (1) A 115 V~
IP 20
50-60 Hz
18 19 20
The ow switch (2) built into the store inlet reacts to the water ow when the tap
is being opened (4). Before actually drawing off water, open the tap for a brief mo-
ment.After that, the control unit (1) puts the circulating pump into operation (3)
in order to let the hot water ow from the store (5) through the circulation line.
When you open the tap again,hot water will arrive there within a few seconds.The
control unit will now switch off the circulating pump again after the adjusted runt-
ime in order to prevent hot water from being pumped through the circulation line
when it is not used. In order to prevent the circulating pump from being switched
on again after a brief pause, the re-start is avoided by the adjustable waiting time.
In the case that the tap has not been opened for 12 hours (e.g. when the user is on
holiday), the pump will be put into operation for the adjusted runtime Rc.This will
protect the store against Legionella that can easily appear when the water is not
owing (Legionella protection). The time value is preadjusted to 12 h.
Note
In order to prevent water from being mixed with water from the cirula-
tion line, a circulating pump with a non-return valve should be used.