Introduction
1
About This Manual
The IQ 700IS indicator represents the latest in
state-of-the-art microprocessor technology
specifically applied to the weighing marketplace. This
manual provides information on installation,
calibration, configuration and operation of the IQ
700IS. The installer should be familiar with the
National Electrical Code and RP 12.6 (
Recommended
Practice
) requirements for installation of equipment
in hazardous areas (NEC Article 504,
Intrinsically
Safe Systems
) published through the Instrument
Society of America.
The IQ 700IS is a Factory
Mutual-approved system. This
approval is valid only if the
installation conforms to the
guidelines described in this manual. If
modifications are made to the installation procedure, the
enclosure is opened, or the instrumentation is changed in
any way, Factory Mutual approval is void and the
customer becomes fully responsible for such
modifications.
This instrument and accompanying equipment must be
installed and serviced by an authorized technician in
accordance with the instructions provided in this manual.
Improper specification, installation, or service of this
equipment could result in personal injury or property
damage.
Authorized distributors and their
employees can view or download this
manual from the Rice Lake Weighing
Systems distributor site at
www.rlws.com
.
1.0 Introduction
The IQ 700IS is a single-channel digital weight
indicator designed and approved to operate as an
intrinsically safe system in a wide variety of scale and
weighing applications. The indicator is housed in a
NEMA 4X stainless steel sealed case. The standard
unit is equipped with a tilt stand base for tabletop or
wall mounting applications. The indicator front panel
consists of a 21-button keypad, six seven-segment
display digits and 11 LED annunciators (see
Figure 1-1 on page 2).
Features of the IQ 700IS include:
•Full front panel digital configuration and
calibration
•Zero and span temperature compensation to
ensure compliance with NTEP temperature
range requirements (–10 to 40°C)
•Nonvolatile memory stores data for
calibration, temperature compensation,
configuration parameters, auto or fixed tare
values, PAZ and AZM values
•Ten-thousand displayed graduations; 80,000
graduation expansion available
NOTE:
Use of more than 20,000 graduations may
cause undesirable display instability in some
applications.
•Analog sensitivity to 0.3
µ
V/grad at 20,000
graduations
•Ten updates per second, with selectable
digital averaging and auto averaging; 5 Hz
active analog filter for smooth response
• Excitation for four 350
Ω
load cells at 5 VDC
•Operable from DC power supply or optional
battery
•Time and date print selection
1.1 Factory Mutual Approval
The IQ 700IS is Factory Mutual (FM) approved for:
• Classes I, II, and III,
•Divisions 1 and 2, and
•Groups A, B, C, D, E, F and G
The Factory Mutual (FM) approval is a system
approval for all devices connected directly to the IQ
700IS digital weight indicator. Other devices that have
FM Entity Approval cannot be used with this system
unless specifically listed in this manual as part of the
Rice Lake Weighing Systems Factory Mutual systems
approval. Failure to comply with this voids the FM
approval. The control drawing is the guide to the
installation of this system.
1.2 System Limitations and
Restrictions
The following items represent limitations and
restrictions on the use of the IQ 700IS:
•All instrumentation must have identification
nameplates in compliance with the control
drawing.
•All wiring, connections, conduit and grounds
Warning