manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Rinnai
  6. •
  7. Indoor Fireplace
  8. •
  9. Rinnai Symmetry RDV3611 User manual

Rinnai Symmetry RDV3611 User manual

Other manuals for Symmetry RDV3611

4

Other Rinnai Indoor Fireplace manuals

Rinnai Arriva 752 User manual

Rinnai

Rinnai Arriva 752 User manual

Rinnai RDV600N User manual

Rinnai

Rinnai RDV600N User manual

Rinnai Neo RIB2312L User manual

Rinnai

Rinnai Neo RIB2312L User manual

Rinnai INBUILT ROYALE - ETR User manual

Rinnai

Rinnai INBUILT ROYALE - ETR User manual

Rinnai Neo User manual

Rinnai

Rinnai Neo User manual

Rinnai 650 User manual

Rinnai

Rinnai 650 User manual

Rinnai Ember Series User manual

Rinnai

Rinnai Ember Series User manual

Rinnai SLIMFIRE 252 User manual

Rinnai

Rinnai SLIMFIRE 252 User manual

Rinnai Ember Series User manual

Rinnai

Rinnai Ember Series User manual

Rinnai RIB2312 L User manual

Rinnai

Rinnai RIB2312 L User manual

Rinnai Neo RIB2311N User manual

Rinnai

Rinnai Neo RIB2311N User manual

Rinnai LS1000 User manual

Rinnai

Rinnai LS1000 User manual

Rinnai Linear Series User manual

Rinnai

Rinnai Linear Series User manual

Rinnai Sapphire RIB2310 User manual

Rinnai

Rinnai Sapphire RIB2310 User manual

Rinnai Royale FS35 ETR User manual

Rinnai

Rinnai Royale FS35 ETR User manual

Rinnai FLAME FIRES User manual

Rinnai

Rinnai FLAME FIRES User manual

Rinnai Evolve 950 User manual

Rinnai

Rinnai Evolve 950 User manual

Rinnai SS850ICLN User manual

Rinnai

Rinnai SS850ICLN User manual

Rinnai Compact 2 RIBF2L User manual

Rinnai

Rinnai Compact 2 RIBF2L User manual

Rinnai RHFE-551FA User manual

Rinnai

Rinnai RHFE-551FA User manual

Rinnai Evolve RHFE950ETRN User manual

Rinnai

Rinnai Evolve RHFE950ETRN User manual

Rinnai Arriva 752 User manual

Rinnai

Rinnai Arriva 752 User manual

Rinnai Symmetry RDV3611 User manual

Rinnai

Rinnai Symmetry RDV3611 User manual

Rinnai Symmetry RDV3611ETRN User manual

Rinnai

Rinnai Symmetry RDV3611ETRN User manual

Popular Indoor Fireplace manuals by other brands

Napoleon NEFL42CHD-1 manual

Napoleon

Napoleon NEFL42CHD-1 manual

Masport WOOD FIRE installation guide

Masport

Masport WOOD FIRE installation guide

JAYLINE SS280 Installation & operation instructions

JAYLINE

JAYLINE SS280 Installation & operation instructions

Heat-N-Glo SL-32S Installation

Heat-N-Glo

Heat-N-Glo SL-32S Installation

kozy heat Bellingham 52 quick start guide

kozy heat

kozy heat Bellingham 52 quick start guide

Paragon Fires ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE owner's manual

Paragon Fires

Paragon Fires ROOM SEALED INSET LIVE FUEL EFFECT GAS FIRE owner's manual

Monessen Hearth LCUF32CR-B Installation & owner's manual

Monessen Hearth

Monessen Hearth LCUF32CR-B Installation & owner's manual

PuraFlame Galena owner's manual

PuraFlame

PuraFlame Galena owner's manual

Dimplex Toluca Deluxe instruction manual

Dimplex

Dimplex Toluca Deluxe instruction manual

SEI TENNYSON FA8544AO Assembly instructions

SEI

SEI TENNYSON FA8544AO Assembly instructions

Dru G25 installation manual

Dru

Dru G25 installation manual

Capital fireplaces Designline DL700 Installation and user instructions

Capital fireplaces

Capital fireplaces Designline DL700 Installation and user instructions

IronStrike VINTAGE VINT-DVS-U Installation and operation

IronStrike

IronStrike VINTAGE VINT-DVS-U Installation and operation

ACR Heat HERITAGE N25 Installation and operating instruction manual

ACR Heat

ACR Heat HERITAGE N25 Installation and operating instruction manual

European Home HVF-42 Installation, operation and owner's manual

European Home

European Home HVF-42 Installation, operation and owner's manual

Quadra-Fire MTVERNINSAE-MBK Owner's manual operation & care

Quadra-Fire

Quadra-Fire MTVERNINSAE-MBK Owner's manual operation & care

Harman Home Heating Accentra Insert Installation & operating manual

Harman Home Heating

Harman Home Heating Accentra Insert Installation & operating manual

Trimline Fires Zircon 1024 installation instructions

Trimline Fires

Trimline Fires Zircon 1024 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Rinnai NZ Ltd Page 1 of 2 11154 Issue B
RDV3611 : SYMMETRY
Vertical Flue Up Rating Instructions (ULPG ONLY)
Must be installed by a certified gas fitter in accordance with all applicable local rules and regulations
The Rinnai Symmetry RDV3611 LPG appliance is factory supplied, with rated input of 30MJ/hr for
installation for Horizontal Vent Terminations only. To ensure that optimum Flame Effect and
Maximum Energy Efficiency is obtained when the unit is being installed with a Vertical Vent
Termination the appliance must be up rated to 33MJ/hr by installing this Kit.
Kit Contents
Quantity
Rinnai Part Number
Comments
Main Injector
1
11534
1.70mm
Data Plate
1
11152
For Vertical Flues ONLY
Instruction Sheet
1
11154
Energy Rating Label (Vertical Flue)
1
Gas Up Rating Procedure
1. Remove Glass assembly 4 x screws; lift and remove.
2. Remove service panel front 2x screws.
3. Remove service panel rear 2x screws; Lift panel out carefully and put to one side (leaving the
CAT5 cable connected to control panel receiver).
4. Remove log set if installed.
5. Remove burner cover.
6. Lift the burner assembly out carefully as it is very fragile. NOTE: Extra care should be taken to
avoid scratching the ceramic panels/ combustion chamber walls.
7. Remove and replace the Main Injector with the one supplied.
8. Gently lift the burner assembly back into place. NOTE: Extra care should be taken to avoid
scratching the ceramic panels/ combustion chamber walls.
9. Refit the burner cover.
10. Install the log set.
11. Fit the Field Converted Data Plate next to the existing dataplate to show that it has been field
up rated
12. Commission & set gas pressures for correct gas type as per gas setting procedure.
13. Reassemble the remaining components in reverse order.
Burner Cover
Burner assembly
Main injector
Pilot head
Rinnai NZ Ltd Page 2 of 2 11154 Issue B
RDV3611 : SYMMETRY
Vertical Flue Up Rating Instructions (ULPG ONLY)
INSTALLERS INFORMATION - TESTING & COMMISSIONING
TESTING PROCEDURE
Turn gas supply on and plug the unit into the
power supply. (Caution 240V.)
TO CHECK BURNER PRESSURE
• Refer to Data Plate; the Technical Specification
section in the service manual.
• Loosen the Outlet Test Point screw and attach
manometer to the test point. The Outlet Test
Point is on the right hand side of Gas Control
(Shown Below)
• Light appliance, adjust to High flame setting
and check pressure.
• If adjustments are necessary, remove the Cap
C. Pressure adjustment screw and nut are on the
front side of Gas Control (Shown Below) and
should be set to the pressures on the data-plate.
High Pressure Setting: Set the POV to the
maximum condition. Use 10mm spanner to screw
in Nut A to increase the outlet pressure and
screw it out to decrease the pressure.
Low Pressure Setting:
Turn off the power to the POV by disconnecting the
POV Test Connection (yellow wires) in main harness.
Keep Nut A stationary, use a screwdriver 6X1 blade
to screw in the Screw B to increase the pressure and
screw it out to decrease it.
Carefully replace the modulator plastic cap.
WARNING: To ensure the correct operation of the
POV it is necessary that the plastic cap C is returned
to its original location.
• After checking the pressure, turn the unit off,
remove manometer and tighten the test point screw.
(reconnect the POV connection in the main harness)
• Turn the appliance on and off a few times to check
ignition.
• When you are satisfied that the appliance is
working correctly, refit the service panels. Refit the
glass assembly and frame(s).
• If you are unable to get the unit to operate
correctly, refer to Troubleshooting in the service
manual before contacting your local service agent.
• It may take approximately 2 hours of operation for
the media to achieve their full flame pattern and
glow.
• During the initial burning in period, some smoke
and smell may be experienced; the appliance should
be run on the high position in a well ventilated room
until these dissipate.
INLET TEST POINT
OUTLET
TEST POINT
C: CAP
A: HIGH PRESSURE
ADJUSTING NUT
B: LOW PRESSURE
ADJUSTING SCREW