manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Rixson
  6. •
  7. Door Opening System
  8. •
  9. Rixson DE 4 PULL User manual

Rixson DE 4 PULL User manual

Hinge (pull) side of door mounting
Double Egress Arm
and Slide Track
AN INCORRECTLY INSTALLED OR IMPROPERLY
ADJUSTED DOOR CLOSER CAN CAUSE
PROPERTY DAMAGE OR PERSONAL INJURY.
THESE INSTALLATION INSTRUCTIONS SHOULD
BE FOLLOWED TO AVOID THE POSSIBILITY OF
MISAPPLICATION OR MISADJUSTMENT.
CAUTION
CAUTION
Combination Door Closer-Holder and Releasing Device
Signaled by External Detection Equipment
All dimensions are in inches and (millimeters) unless otherwise noted.
NOTE: For special applications a separate door and frame preparation template is packed with these
instructions. Use this instruction sheet for installation sequence and closer adjustments only.
Requirements:





Units are handed. Hand of unit and hand of door must be the
same.
Door must be hung on butt hinges or ¾” (19) offset pivots.
Door thickness must be 1¾” (44) minimum 2¼” (64) maximum.
Door must swing freely through the entire opening and closing
cycle before beginning the installation procedure.
Frame face must be a minimum of 2” (51).
Use of an auxiliary door stop, by
others, is required.
Backplate
Mtg Screw (5)
Arm Screw
Track Mtg
Screw (3)
Cover
Backplate
Hook-up Board
Main Arm
Slide Track
Concealed Wired Unit Shown
Cover Mtg
Screw (3)
RH - Right Hand Door
LHR - Left Hand Reverse
Left Hand Door - LH
Right Hand Reverse - RHR
Installation Instructions
80-9372-0094-015 (02-09)
Selective Hold Open
Cam & Switch
Assembly
Closer/Holder
Test Switch
Access Tube
Slide Assembly
9/32” (7 mm);
3/8” (9.5 mm) dia. x
3/8” (9.5 mm) deep on
door opposite to closer
Standard
Optional Through-bolts and
grommet-nuts
All
Preparation for Fasteners
Door or Frame
Fasteners Drill-Sizes
1/4” - 20 machine
screw Metal Drill: #7 (0.201” dia.)
Tap: 1/4” - 20
Sleeve nuts and bolts
Hollow
Metal
9/32” (7 mm) through;
3/8” (9.5 mm) door face
opposite to closer
Aluminum
or Wood 3/8” (9.5 mm) through

Ceiling clearance must be a minimum of 4” (102).
Power input to unit must be of the same voltage as that stated
on the unit.
Unit to be mounted on interior of building in dry environment,
maximum humidity of 95%.
See NFPA70 for wiring requirements and NFPA72 for alarm
system requirements.



Ceiling Line
2
(51)
4
(102)
Min
Min
Support Unit
Models
DE 4 PULL
Selective Multipoint
Hold Open
Note:
Only for
hinge side
frame reveals
of 1/8” to 3”
(3mm to
76mm)
3A
For Concealed Wire Only
11
(279)
4
(102)
22
(559)
1-13/16
(46)
CHinge or Pivot
3-1/4
(83)
4
(102)
4-1/8
(105)
11-3/8
(289)
4-15/16
(125)
15-7/16
(392) For Concealed
Wiring Only
7/8
(22)
DIA THRU
1-3/8
(35)
1-1/16
(27)
1
2
Determine Hand
RH - Right Hand Door
LHR - Left Hand Reverse
Left Hand Door - LH
Right Hand Reverse - RHR
5
4
6
7
3B
For Surface Wired Only
For Surface Wired Only
Fully close
Latch and
Sweep
Valves with
1/8” wrench
provided.
Page 2


Right hand door shown,
left hand opposite.
All dimensions shown in
inches (mm).
80-9372-0094-015 (02-09)
R OTAT E
TO HERE,
THEN REMOVE
R OTAT E
TO HERE,
THEN REMOVE
8B
PINION
FLAT
LEFT
HAND
RIGHT
HAND
8C
9
Open Latch
and Sweep
Valves
with 1/8”
wrench
provided.
10
+
12
Product shipped
with closing force
set at the middle of
the power range.
!
11
Caution:
Don't completely
close backcheck valve
++
Closing Force Backcheck
Sweep
13 14 Latch
MAKE ELECTRICAL CONNECTIONS:


Power input to unit must be of the same voltage as
that listed on the label.
All wiring connections use standard wiring practice
15
Slide
Assembly
Arm Stud
75°
5° 5°
95°
75°
Page 3
2
1
80-9372-0094-015 (02-09)
1/8” wrench
provided
8A
Main Arm
Arm Washer
Arm Screw
1/8” wrench
provided
1/8” wrench
provided
11/16”
Drive
START
HERE
START
HERE
RE-INSTALL
HERE


Maximum wire size is 18AWG.
Make input power connections to the hook-up board
terminal strip using illustration on Page 4 and wiring
instructions 80-9342-0902-021.
Support Unit Wiring Diagram
(24VAC/DC Input)
Support Unit Wiring Diagram
(120VAC Input)
SHO SOL
1
2
3
1
2
3
4
24VAC/DC Circuit Board 4-Pin
Jumper
SHO SOL
1
2
3
1
2
3
4
120VAC Circuit Board 4-Pin
Jumper
24V AC/DC INPUT CIRCUIT BOARD
(shown with 4-pin jumper for non-detectored units)
120V AC INPUT CIRCUIT BOARD
(shown with 4-pin jumper for non-detectored units)
Selective Hold-
Open
Connection
Selective Hold-Open
Connection
Solenoid
Connection
Solenoid
Connection
120V AC
Power Input
Test Switch
Test Switch
Fuse
PTO125V
(125V / 1/2A)
Fuse
PTO125V
(125V / 1/2A)
24V AC/DC
Power Input
Selective Hold Open Range
These units feature hold open (as shipped) starting at 85°. These units will hold open at virtually any degree of door opening from
85° to 180°. The hold open starting point may be changed (increased or decreased) by loosening the selective hold open cam
screw, rotating the cam to the desired new starting point and re-tightening the cam screw.
Setting
Door
Angle
G H J K L M
15° 30° 45° 60° 90° 135°
16
17
15
cont
Page 4
HOT (+)
COM (-)
HOT (+)
COM (-)
120VAC 24VAC 24VDC
Voltage
Current
120V 24V 24V
132V Max
102V Min
26.4V Max
20.4V Min
26.4V Max
20.4V Min
.036 Amps .059 Amps .074 Amps
4-Pin Jumper 4-Pin Jumper
5/32” wrench
provided
5/32” wrench
provided
An ASSA ABLOY Group Co.
3000 Highway 74 East • Monroe, NC 28112
Tel:
ww.rixson.com
(800)-457-5670
w
Rixson ® is a registered trademark of Yale Security Inc., an ASSA ABLOY
Group company. Copyright © 2009 Yale Security Inc., an ASSA ABLOY
Group company. All rights reserved. Reproduction in whole or in part
without the express written permission of Yale Security Inc. is prohibited.
80-9372-0094-015 (02-09)

Other Rixson Door Opening System manuals

Rixson ASSA ABLOY 328 User manual

Rixson

Rixson ASSA ABLOY 328 User manual

Rixson ASSA ABLOY 50 User manual

Rixson

Rixson ASSA ABLOY 50 User manual

Rixson DE 6 PULL User manual

Rixson

Rixson DE 6 PULL User manual

Popular Door Opening System manuals by other brands

Record KEANE MONROE 2000 Series installation instructions

Record

Record KEANE MONROE 2000 Series installation instructions

GEZE Powerturn Series Installation and service instructions

GEZE

GEZE Powerturn Series Installation and service instructions

Assa Abloy Corbin Russwin ED5400 (A) Series installation instructions

Assa Abloy

Assa Abloy Corbin Russwin ED5400 (A) Series installation instructions

Dorma TS93 T installation guide

Dorma

Dorma TS93 T installation guide

Fortstrong FH-8400 Series installation instructions

Fortstrong

Fortstrong FH-8400 Series installation instructions

Automatic Technology Axess Pro 1505 installation instructions

Automatic Technology

Automatic Technology Axess Pro 1505 installation instructions

DORIC DS5010 installation guide

DORIC

DORIC DS5010 installation guide

INOX EL-PTC-20 installation instructions

INOX

INOX EL-PTC-20 installation instructions

BFT BRCT Installation and user manual

BFT

BFT BRCT Installation and user manual

PDQ 7101 instruction sheet

PDQ

PDQ 7101 instruction sheet

CornellCookson SGHN4-300 E Series Installation instructions and operation manual

CornellCookson

CornellCookson SGHN4-300 E Series Installation instructions and operation manual

RIB SLIDER ACG9460 manual

RIB

RIB SLIDER ACG9460 manual

Perko Power R102 quick start guide

Perko Power

Perko Power R102 quick start guide

DITEC DAS200T Original instructions

DITEC

DITEC DAS200T Original instructions

GFS e-Bar 700 71 Series Assembly instruction

GFS

GFS e-Bar 700 71 Series Assembly instruction

SALICE Lapis Assembly instructions

SALICE

SALICE Lapis Assembly instructions

Scrigno OPEN1000 Assembly manual

Scrigno

Scrigno OPEN1000 Assembly manual

Synergy Hardware S800 Series Fixing instructions

Synergy Hardware

Synergy Hardware S800 Series Fixing instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.