4
CONGRATULATIONS AND THANK YOU FOR
PURCHASING THIS ROCA PRODUCT
This spahasbeendesigned,manufacturedandchecked by
our technical staff. It should be installed in accordance with
current regulations following all the applicable instructions.
BREACH OF THIS CONDITION RENDERS THE
PRODUCT WARRANTY NULL AND VOID.
This spa is designed for private use.
GENERAL SPECIFICATIONS
There are two versions of Broadway Maxi:
- With wooden panels, to be installed on the ground floor.
Product Reference: 8S3090..0
- Withouth wooden panels, to be installed imbedded in
the ground floor. Product Reference: 8S309S..0
WATER MASSAGE:
•2 hydromassage pumps with power of 2,7 Hp (2,0
kW) every
•Jets:
- regular mini jets - 41 pcs.
- fixed ozone mini jet - 1 pcs.
- 3” adjustable rotating stream - 2 pcs.
- 3” adjustable rotating dual stream - 4 pcs.
- 3” multi-shower multi-massage - 2 pcs.
- 3” pulsating shower galaxy massage - 2 pcs.
- 3” pulsating stream massage - 4 pcs.
- 3 3/8” adjustable rotating dual stream - 3 pcs.
- 3 3/8” pulsating stream massage - 4 pcs.
- 5” rotating alternating splash gyro - 4 pcs.
- 5” alternating splash resonator - 1 pcs.
- big jet geyser - 1 pcs.
DISINFECTION SYSTEM:
• 1 Ozone generator
FILTERING:
•1 pump two-speed for hydromassage & filtration
with power of 0,48 kW/2,1 kW
WATER HEATER ELEMENT:
• 3 kW electric heater
SPECIFICATIONS:
• Only for private use
• Number of people: 7
•Capacity - 1750 litres.
•Dimensions -2230/2230mm.
•Depth - 900 mm.
•Weight - ~500 kg (empty bath) with panel and cover
•Mains supply - 3 x 4 mm2 for power 240VAC; 6,5 kW
1. RECEIVING THE EQUIPMENT
The spa should reach its destination in its original
packaging.Packagingtotalmeasuresis1530x2500x2390.
Once the packaging has been removed, check the spa
fully before it is installed and report any anomaly.
Do not lift the spa using the filter equipment or the pipes.
Do not stand the pool on its edge. Always stand it on its
legs.
During the installation, check that the interior of the spa is
protected by the covering included with the equipment.
Electrical installation and pipe connections must be
carried out by authorised installers.
2. PREPARING PLACE FOR THE
INSTALLATION
Broadway Maxi Spa can function indoors and outdoors.
It must be installed on a firm base to prevent it from
sinking. When choosing the location for the spa, a series
of requirements must be taken into account:
1. Environment - room:
- If you have decided to install the spa indoors, bear in
mind the thoroughfares required for transporting it to its
final location.
- There must be adequate ventilation in closed interior
locations. Refer to 7. - Section in this manual.
- You must bear in mind the materials used on the wall
and ceilings, since the humidity generated by the spa
requires steam-resistant materials.
- Due to unavoidable splashing, the floor must be highly
resistant to water, such as tiles or plastic coverings. If
carpets are used, it must be treated to avoid bacteria from
damp. Use special sailing carpets or rugs. Parquet or
wooden floors are not advisable unless they have been
duly treated for this kind of use, such as wood for gardens
or outdoor buildings. In any case, make sure that the floor
hasagradientof2%gradientflooroutsidespa)withleveled
floor for the spa towards a drain installed in the room.
- This spa has got two versions:
-Withouthwoodenpanels:It will beinstalledimbedded
in the ground floor (proper ventilation with fresh air for
electrical equipment is needed).
Please, refer to fig. number 1-a to see exact measures
to prepare the ground whole.
- With wooden panels. It is a not an imbedded version,
spa will be installed on the ground. The floor must be
perfectly levelled.Refer to fig. 1-b
2. Hydraulical matters:
- Access to interior components for post-installation
maintenance. Refer to fig. 2.
- You must also bear in mind how you are going to fill and
empty the pool. The floor must be leveled.
3. Electrical matters:
- The electrical connection of the equipment must be
carriedoutwitha3conductorcablewithasectionof4mm2
and ready for 240 VAC (the nominal power consumed by
the standard equipment is equal to 6,5 kW).
- An earth connection compliant with current legislation
is essential. The electrical installation of the spa must
be protected by 10 mA* RCD circuit breaker and a 40
A magnetothermal switch with omnipolar disconnection
devicesandadistancebetweencontactsofatleast3mm.
Both switches must be situated outside the zones as
shown in fig. 3.
* Adjust this value to your geographical current legislation