Rohm BM3G015MUV-EVK-003 User manual

650 V GaN HEMT Power Stage
BM3G015MUV-EVK-003

Notice
www.rohm.com HVB01E
© 2018 ROHM Co., Ltd. All rights reserved.
<
High Voltage Safety Precautions
>
◇
Read all safety precautions before use
Please note that this document covers only the BM3G015MUV evaluation board
(BM3G015MUV-EVK-003) and its functions. For additional information, please refer to
the datasheet.
To ensure safe operation, please carefully read all precautions before
handling the evaluation board
Depending on the configuration of the board and voltages used,
Potentially lethal voltages may be generated.
Therefore, please make sure to read and observe all safety precautions described in
the red box below.
Before Use
[1] Verify that the parts/components are not damaged or missing (i.e. due to the drops).
[2] Check that there are no conductive foreign objects on the board.
[3] Be careful when performing soldering on the module and/or evaluation board to ensure that solder
splash does not occur.
[4] Check that there is no condensation or water droplets on the circuit board.
During Use
[5] Be careful to not allow conductive objects to come into contact with the board.
[6] Brief accidental contact or even bringing your hand close to the board may result in
discharge and lead to severe injury or death.
Therefore, DO NOT touch the board with your bare hands or bring them too close to the board.
In addition, as mentioned above please exercise extreme caution when using conductive tools such as
tweezers and screwdrivers.
[7] If used under conditions beyond its rated voltage, it may cause defects such as short-circuit or,
depending on the circumstances, explosion or other permanent damages.
[8] Be sure to wear insulated gloves when handling is required during operation.
After Use
[9] The ROHM Evaluation Board contains the circuits which store the high voltage. Since it stores the
charges even after the connected power circuits are cut, please discharge the electricity after using
it, and please deal with it after confirming such electric discharge.
[10] Protect against electric shocks by wearing insulated gloves when handling.
This evaluation board is intended for use only in research and development facilities and
should by handled only by qualified personnel familiar with all safety and operating
procedures.
We recommend carrying out operation in a safe environment that includes the use of high
voltage signage at all entrances, safety interlocks, and protective glasses.

1/6
© 2023 ROHM Co., Ltd.
No. 66UG019E Rev.001
JUN.2023
User’s Guide
Figure 1. BM3G015MUV-EVK-003
650 V GaN HEMT Power Stage
BM3G015MUV Evaluation Board
BM3G015MUV-EVK-003
General Description
The BM3G015MUV-EVK-003 evaluation board consists of the BM3G015MUV (GaN FET (650 V 150 mΩ), integrated driver and protection circuit)
and A board on which peripheral components are mounted
.
This IC is designed to adapt major exist controllers, so that it also can be used to replace the traditional discrete power switches, such as super
junction MOSFET.

2/6
User’s Guide
BM3G015MUV-EVK-003
© 2023 ROHM Co., Ltd. No. 66UG019E Rev.001
JUN.2023
Performance Specification
Not guarantee the characteristics is representative value.
Unless otherwise specified VDD = 15 V VBUS=200 V , Tj = 25 ℃
.
Measurement Circuits
Parameter Symbol
Min Typ Max Units Conditions
Power Supply Voltage Range VDD 6.25 15 35 V
Drain Voltage Range VDRAIN - - 650 V
VDD Quiescent Current ION2 - 0.18 0.24 mA VIN=0 V
Positive-going Input Threshold VIN_POS 1.60 1.80 2.00 V
Negative-going Input Threshold
VIN_NEG 1.05 1.30 1.55 V
Turn-on Slew Rate SRON1 28 V/ns
Operating Temperature -10 +25 +105 °C

3/6
User’s Guide
BM3G015MUV-EVK-003
© 2023 ROHM Co., Ltd.
No. 66UG019E Rev.001
JUN.2023
Figure 2. Diagram of How to Connect
Operation Procedure
1. Operation Equipment
(1) DC power supply (400 VDC, 100 W or more)
(2) DC power supply (30 VDC,10 W or more)
(3) Oscilloscope
(4) Oscillator
2. Connect method
(1) Preset the DC supply 1 to 200 V and turn off the DC supply output.
(2) Preset the DC supply 2 to 15 V and turn off the DC supply output.
(3) Turn off the oscillator output.
(4) As shown in the connection diagram, connect the evaluation board to each measuring instrument and DC supply.
(5) Turn on the output of DC supply 1 and DC supply 2, and turn on the output of the oscillator.
(6) Check the voltage on the D and G pins

4/6
User’s Guide
BM3G015MUV-EVK-003
© 2023 ROHM Co., Ltd.
No. 66UG019E Rev.001
JUN.2023
Figure 4. TOP Layout (Top view)
Figure 3. BM3G015MUV-EVK-003 Schematics
Figure 5. Bottom Layout (Top View)
Schematics
Parts List
Materials may be changed without notifying.
Layout
Size: 19 mm x 22 mm
Item Specification Parts Name Manufacurer
C1 0.1 μF,50 V GRM188R72A104KA35D MURATA
C2 0.1 μF,50 V GRM188R72A104KA35D MURATA
C3 30 pF,50 V GRM1882C1H330JA01# MURATA
IC1 Rdson 150 mΩ,650 V BM3G015MUV ROHM
L1 600Ω at 100MHz BLM18AG601SN1D MURATA
R1 47 Ω MCR03EZPJ470 ROHM
R2 0 Ω MCR03EZPJ000 ROHM
R3 Non-Mounted
R4 Non-Mounted
PCB PCB0275D SIGNAS

5/6
User’s Guide
BM3G015MUV-EVK-003
© 2023 ROHM Co., Ltd.
No. 66UG019E Rev.001
JUN.2023
Figure 6. Pin Configuration
BM3G015MUV General Description
Features
Nano Cap
TM
Integrated Output Selectable 5 V LDO
Long Time Support Product for Industrial Applications
Wide Operating Range for VDD Pin Voltage
Wide Operating Range for IN Pin Voltage
Low VDD Quiescent and Operating Current
Low Propagation Delay
High dv/dt Immunity
Adjustable Gate Drive Strength
Power Good Signal Output
VDD UVLO Protection
Thermal Shutdown Protection
Pin Configuration
Key Specifications
Power Supply Voltage Range
VDD pin: 6.25 V to 30 V
D pin: 650 V (Max)
IN pin: -0.6 V to +30 V
VDD Operating Current @ 130 kHz: 650 μA (Typ)
VDD Quiescent Current: 180 μA (Typ)
Allowable Input Switching Frequency: 2 MHz (Max)
Turn-on Delay Time: 12 ns (Typ)
Turn-off Delay Time: 15 ns (Typ)
Operating Temperature Range: -40 °C to +105 °C
GaN HEMT D-S ON State Resistance:150 mΩ (Typ)
Package W (Typ) x D (Typ) x H (Max)
VQFN046V8080 8.0 mm x 8.0 mm x 1.0 mm
pitch 0.5 mm
Pin Descriptions
Pin No. Pin Name
I/O Function
1,2,17-22,24-32 S O GaN HEMT SOURCE pin
3 LDOEN
I LDO function enable /disable pin
4,13 GND O GND pin
5,7,9,10,14,16,23,24 N.C. - Non-connection
6 VDD I Power supply input pin
8 LDO5V O 5V LDO output pin
11 PG O Power Good signal output pin
12 RSR I Gate drive strength adjustment pin
15 IN I Non-inverting gate drive input
33-46 D I GaN HEMT DRAIN pin
- EXP O GaN HEMT SOURCE pin
- C.S Corner pin
- C.N.C Corner pin, Non-connection

6/6
User’s Guide
BM3G015MUV-EVK-003
© 2023 ROHM Co., Ltd. No. 66UG019E Rev.001
JUN.2023
Revision History
Date Rev. Changes
1.June.2023 001 New Release

www.rohm.com
Notice
ROHM Customer Support System
R2043A
The information contained in this document is intended to introduce ROHM Group (hereafter
referred to asROHM) products. When using ROHM products, please verify the latest specifications
or datasheets before use.
ROHM products are designed and manufactured for use in general electronic equipment and
applications (such as Audio Visual equipment, Office Automation equipment, telecommunication
equipment, home appliances, amusement devices, etc.) or specified in the datasheets. Therefore,
please contact the ROHM sales representative before using ROHM products in equipment or
devices requiring extremely high reliability and whose failure or malfunction may cause danger or
injury to human life or body or other serious damage (such as medical equipment, transportation,
traffic, aircraft, spacecraft, nuclear power controllers, fuel control, automotive equipment including
car accessories, etc. hereafter referred to as Specific Applications). Unless otherwise agreed in
writing by ROHM in advance, ROHM shall not be in any way responsible or liable for any damages,
expenses, or losses incurred by you or third parties arising from the use of ROHM Products for
Specific Applications.
Electronic components, including semiconductors, can fail or malfunction at a certain rate. Please
be sure to implement, at your own responsibilities, adequate safety measures including but not
limited to fail-safe design against physical injury, and damage to any property, which a failure or
malfunction of products may cause.
The information contained in this document, including application circuit examples and their
constants, is intended to explain the standard operation and usage of ROHM products, and is not
intended to guarantee, either explicitly or implicitly, the operation of the product in the actual
equipment it will be used. As a result, you are solely responsible for it, and you must exercise your
own independent verification and judgment in the use of such information contained in this
document. ROHM shall not be in any way responsible or liable for any damages, expenses, or
losses incurred by you or third parties arising from the use of such information.
When exporting ROHM products or technologies described in this document to other countries, you
must abide by the procedures and provisions stipulated in all applicable export laws and regulations,
such as the Foreign Exchange and Foreign Trade Act and the US Export Administration
Regulations, and follow the necessary procedures in accordance with these provisions.
The technical information and data described in this document, including typical application circuits,
are examples only and are not intended to guarantee to be free from infringement of third parties
intellectual property or other rights. ROHM does not grant any license, express or implied, to
implement, use, or exploit any intellectual property or other rights owned or controlled by ROHM or
any third parties with respect to the information contained herein.
No part of this document may be reprinted or reproduced in any form by any means without the
prior written consent of ROHM.
All information contained in this document is current as of the date of publication and subject to
change without notice. Before purchasing or using ROHM products, please confirm the latest
information with the ROHM sales representative.
ROHM does not warrant that the information contained herein is error-free. ROHM shall not be in
any way responsible or liable for any damages, expenses, or losses incurred by you or third parties
resulting from errors contained in this document.
Thank you for your accessing to ROHM product informations.
More detail product informations and catalogs are available, please contact us.
Notice
© 2023 ROHM Co., Ltd. All rights reserved.
https://www.rohm.com/contactus
1)
2)
3)
4)
5)
6)
7)
8)
9)
This manual suits for next models
1
Table of contents
Other Rohm Industrial Equipment manuals

Rohm
Rohm SuperLock HSK Series User manual

Rohm
Rohm SZS User manual

Rohm
Rohm DURO-M Operational manual

Rohm
Rohm DURO-A Operational manual

Rohm
Rohm KZS-P Operational manual

Rohm
Rohm FORTO-H 70 Operational manual

Rohm
Rohm RB-K User manual

Rohm
Rohm BM2P0363F-EVK-001 User manual

Rohm
Rohm DURO-A RC Operational manual

Rohm
Rohm KZS-H Operational manual