Rosslare AY-Q54 User manual

ROSSLARE
INSTRUCTION MANUAL
AY-Q54
KEYPAD READER
WIEGAND AND CLOCK & DATA
08/01
9J-IDR-024-A / 0706-0820024-01
ROSSLA R E
www.rosslare.com.hk
ROSSLA R E
123
456
789
0#

Page 3 06/01
Introduction
Equipment provided
The following is provided as part of every AY-Q54 package:
The AY-Q54 is a vandal resistant programmable keypad reader. The
AY-Q54 supports multiple keypad formats providing a high level of
compatibility and connectivity with host controllers.
The keypad can be programmed to output eight different data
formats.
- AY-Q54 Access Control Unit.
- Installation Kit
- Installation and Operating Instructions
5 to 16V DC (From a Regulated Power Supply)
Other Rosslare accessories can be found at Rosslare's
Web Site:
http://www.rosslare.com.hk
Additional Equipment Required
1) Compatible Host Controller
2) Power Supply
AY-Q54
Page 2 06/01
Contents
Technical Specifications 4
Key Features 5
Mounting the AY-Q54 reader 6
Wiring the AY-Q54 reader 7
Transmit Mode 8
Entering Programming Mode 10
Exiting Programming Moe Operation 10
1 Setting Keypad Transmission Format 11
3 Changing the Programming Code 18
4 Changing the Facility Codes 19
0 Return to Factory Default Settings 19
Replacing a lost Programming Code 20
INTRODUCTION
INSTALLATION
FEATURES AND CONCEPTS
PROGRAMMING THE AY-Q54
TECHNICAL SUPPORT
3
6
9
21
AY-Q54

Page 5 08/01
Operating Humidity:
Dimensions:
Weight:
0 to 95% (Non-Condensing)
Suitable for outdoor use. (IP 44)
4.72" (120mm) L x 3" (76mm) W x 1" (27mm) D
0.9 lbs (410g)
Built-In Keypad for PIN code entry
Programmable Keypad Transmission Format
Built in Case and Back Tamper
Tamper Output & LED Control Input
Programmable Facility Code
Two Tri-Colored LED’s
Internal Buzzer provides audible interface feedback.
Comes with mounting template for easier installation.
Comes with Installation Kit that includes a security screw
and a security screw tool.
Mechanical Characteristics
!
!
!
!
!
!
!
!
!
Key Features
Here are some of the AY-Q54's key features:
AY-Q54
06/01
Technical Specification
Electrical Characteristics
Environmental Characteristics
Operating Voltage Range:
Maximum Input Current:
Built-In Keypad Reader
LED Control Input
Tamper Output
Operating Temperature:
5 to 16V DC From a Regulated Power Supply
(Linear type recommended)
Standby: 20mA Not including attached devices
Max: 60mA Not including attached devices
Transmission Formats:
1) Single Key, 6-Bit Wiegand (Rosslare Format)
2) Single Key, 6-Bit Wiegand with Nibble and Parity Bits
3) Single Key, 8-Bit Wiegand, Nibbles Complemented
4) 4 Keys Binary + Facility Code, 26-Bit Wiegand
5) 1 to 5 Keys + Facility Code, 26-Bit Wiegand
6) 6 Keys BCD and Parity Bits, 26-Bit Wiegand
7) Single Key, 3x4 Matrix Keypad
8) 1 to 8 Keys BCD, Clock & Data
Dry Contact, N.O.
Open Collector, active low, maximum sink current is 32mA
-25°F to 145°F (-31°C to 63°C)
Page 4
AY-Q54

Page 6 06/01
Installation
Mounting the AY-Q54 Controller
1)
2)
3)
4)
5)
6)
Before starting, select the location to mount the AY-Q54 reader.
This location should be at shoulder height.
Drill holes into the back of the metal according to how you want
to mount the AY-Q54. For US Gang Box installation there are two
hole indicators on the back of the metal cover specifically aligned
for the US Gang Box. (Shown marked as ”A” in diagram below).
For a four screw custom installation there are four indicators on
the back. (Shown marked as B on the diagram below)
Route the interface cable from the Reader to the Controller. A
linear type power supply is recommended.
Screw the AY-Q54 back cover to its mounting location.
Return the front cover of the AY-Q54 to the mounted back plate.
Secure the front cover by using the supplied security screw in the
controllers Installation Kit. An L-Shaped tool is provided for use
when tightening the security screw.
AY-Q54
A
A
BB
BB
CAUTION!
DO NOT DRILL
This is the Tamper Lens
Page 7 06/01
Wiring the AY-Q54
The reader is supplied with a 16-inch pigtail, having a 6-conductor
cable. To connect the Reader to the Controller, perform the
following steps.
Prepare the Reader cable by cutting the cable jacket back 1¼
inches and strip the wire ½ inch. Prepare the Controller cable by
cutting the cable jacket back 1¼ inches and strip the wire ½
inch.
Splice the Reader pigtail wires to the corresponding Controller
wires and cover each connection.
Table shows how you
should wire the Reader
to the controller.
If the tamper output is being utilized, connect the purple wire to
the correct input on the Controller.
4) Trim and cover all conductors that are not used.
1)
2)
3)
AY-Q54
Red
Black
White
Green
Brown
Purple
+V DC
Ground
Data 1 / Clock
Data 0 / Data
LED Control
Tamper
COLOR OUTPUT

Programming the AY-Q54
Programming the AY-Q54 is done solely via the unit's keypad driven
Programming Menu System. To reach the Programming Menu
System the AY-Q54 must first be placed into Programming Mode.
See "Entering Programming Mode" on the next page for more
information.
During the AY-Q54's manufacturing process certain codes and
settings are pre-programmed. These settings are the called the
"Default Factory Settings".
The table below shows the names of all the AY-Q54 Menus.
1) Single Key, 6-Bit Wiegand (Rosslare Format)
2) Single Key, 6-Bit Wiegand with Nibble + Parity Bits
3) Single Key, 8-Bit Wiegand, Nibbles Complemented
4) 4 Keys Binary + Facility Code, 26-Bit Wiegand
5) 1 to 5 Keys + Facility Code, 26-Bit Wiegand
6) 6 Keys BCD and Parity Bits, 26-Bit Wiegand
7) Single Key, 3x4 Matrix Keypad
8) 1 to 8 Keys BCD, Clock & Data Single Key,
Programming Menu
Selecting Keypad Transmission Format 1
Changing the Programming Code 3
Changing the Facility Code 4
Return to Factory Default Settings 0
Page 09 06/01
AY-Q54
Menu Description Menu
Number
Transmit Mode
When the AY-Q54 is in Transmit Mode, it is ready to receive data
from an entered PIN code.
When the reader is in Transmit
Mode, the Transmit LED is red
and the Program LED is off
When a Keyboard entry is being transmitted, the Transmit LED
will flash green.
Keyboard data can be sent via one of eight different Keypad
Transmission Formats. (Refer to page 13 for more information on
Selecting Keypad Transmission Formats”)
Page 08 06/01
AY-Q54
Transmit Program
RED

Selecting Keypad Transmission Format
The AY-Q54 has eight different keypad transmission formats to
select from. Follow the steps below to select the appropriate keypad
transmission format that you wish to use.
Enter Programming Mode
Press to enter
The Transmit LED will turn red
Enter the appropriate option number
for the keypad transmission format
that you wish to select.
If an incorrect option number is entered the reader will return to
Transmit Mode and the keypad transmission format will remain
unchanged
Look on the next page for more information on the keypad
transmission formats.
System returns to Transmit Mode
You will hear one beep
The Program LED will turn off
The Transmit LED will turn red
- Only one keypad transmission format can be active at
any one time.
- When using the keypad transmission format “1 to 8 keys
BCD, Clock & Data” (Option 8) an additional input is
required to specify the number of keys in the PIN code.
1)
2) "1" Menu 1
3)
4)
Note:
!
!
!
!
Page 11 06/01
AY-Q54
Transmit Program
GREEN
Page 10 06/01
Entering Programming Mode
Exiting Programming Mode
1) "#"
2)
Note:
1)
"#"
2)
3)
Press the key for 2 seconds.
Transmit LED will turn off
Program LED will turn red
Enter your 4-digit Programming
Code.
If the Programming Code
is valid the door LED will turn
green and the AY-Q54 will be in
Programming Mode.
- The factory default Programming Code is 1234
- If a Programming Code is not entered within 30
seconds, the AY-Q54 will return to Transmit Mode.
To exit the Programming Mode at any time:
Press the key.
You will hear a beep
The Program LED will be off
The Transmit LED will turn green
This indicates that the AY-Q54 has returned to Transmit Mode.
Wrong entries may reset the read
1to8
to Transmit Mode.
While in Programming Mode if no key is pressed for 30 seconds
the AY-Q54 will exit Programming Mode and return to Transmit
Mode.
!
!
!
!
!
AY-Q54
Transmit Program
Transmit Program
GREEN
RED
1234
Transmit Program
GREEN 1
?
Transmit Program
GREENRED
Transmit Program
RED

Keypad Transmission Format Option Number
Single Key, 6-Bit Wiegand (Rosslare Format)
See the table below to determine the Option Number for the Keypad
Transmission Format you wish to select.
Single Key, 6-Bit Wiegand (Rosslare Format) 1
Single Key, 6-Bit Wiegand with Nibble + Parity Bits 2
Single Key, 8-Bit Wiegand, Nibbles Complemented 3
4 Keys Binary + Facility Code, 26-Bit Wiegand 4
1 to 5 Keys + Facility Code, 26-Bit Wiegand 5
6 Keys BCD and Parity Bits, 26-Bit Wiegand 6
Single Key, 3x4 Matrix Keypad 7
1 to 8 Keys BCD, Clock & Data Single Key, 8
More information on each of the different keypad transmission
formats is available below and on the following pages.
Each key press immediately sends 4 bits with 2 parity bits added.
Even parity for the first 3 bits and odd parity for the last 3 bits.
0 = 1 1010 0 6 = 1 0110 0
1 = 0 0001 0 7 = 1 0111 1
2 = 0 0010 0 8 = 1 1000 1
3 = 0 0011 1 9 = 1 1001 0
4 = 1 0100 1 = 1 1011 1 = “B” in Hexadecimal
5 = 1 0101 0 # = 0 1101 1 = “C” in Hexadecimal
Each key press immediately sends 4 bits with 2 parity bits added.
Even parity for the first 3 bits and odd parity for the last 3 bits.
0 = 0 0000 1 6 = 1 0110 0
1 = 0 0001 0 7 = 1 0111 1
2 = 0 0010 0 8 = 1 1000 1
3 = 0 0011 1 9 = 1 1001 0
4 = 1 0100 1 = 1 1010 0 = “B” in Hexadecimal
5 = 1 0101 0 # = 1 1011 1 = “C” in Hexadecimal
Inverts the most significant bits in the message leaving the least 4
significant bits as Binary-Coded Decimal (BCD) representation of
the key. The host system receives an 8-bit message.
0 = 11110000 6 = 10010110
1 = 11100001 7 = 10000111
2 = 11010010 8 = 01111000
3 = 11000011 9 = 01101001
4 = 10110100 = 01011010 = “A” in Hexadecimal
5 = 10100101 # = 01001011 = “B” in Hexadecimal
Buffers 4 keys and outputs keypad data with a three digit facility
code like a standard 26-Bit card output.
The facility code is set in Programming Menu number four and can
be in the range 000 to 254. The factory default setting for the facility
code is 000. (See page 21 for more information on “Changing the
Facility Code”)
Single Key, 6-Bit Wiegand, Nibble & Parities
Single Key, 8-Bit Wiegand, Nibbles Complemented
4 Keys Binary + Facility Code, 26-Bit Wiegand
Page 13 06/01
AY-Q54
Page 12 06/01
AY-Q54
Keypad Transmission Format Option
Number
OPTION 1
OPTION 2
OPTION 3
OPTION 4

The keypad PIN code must be 4 digits long and can range between
0001 and 9999. On the fourth key press of the 4 digit PIN code, the
data is sent across the Wiegand Data lines as binary data in the
same format as a 26-Bit Card.
If the “ “ key or the “ “ key are pressed during PIN code entry, the
keypad will clear the PIN code entry buffer, generate a beep and is
ready to receive a new 4 digit keypad PIN code.
If the entry of the 4 digit keypad PIN code is disrupted and no
number key is pressed within 5 seconds, the keypad will clear the
PIN code entry buffer, generate a beep and is ready to receive a
new 4 digit keypad PIN code.
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP)
Where: EP = Even parity for first 12 bits.
OP = Odd parity for last 12 bits.
F = 8-Bit Facility Code.
A = 24-Bit code generated from keyboard.
Buffers up to 5 keys and outputs keypad data with a facility code
like a 26-Bit card output.
The facility code is set in Programming Menu number four and can
be in the range 000 to 254. The factory default setting for the facility
code is 000. (See page 21 for more information on “Setting the
Facility Code”)
The keypad PIN code can be one to five digits long and can range
between 1 and 65,535. When entering a keypad PIN code that is
less than 5 digits long, the “ ” key must be pressed to signify the
end of PIN code entry. For keypad PIN codes that are 5 digits long,
on the fifth key press of the 5 digit PIN code, the data is sent across
the Wiegand Data lines as binary data in the same format as a 26-
Bit Card.
#
#
1 to 5 Keys + Facility Code, 26-Bit Wiegand
If the “ “ key or the “ “ key are pressed during PIN code entry or a
PIN code greater than 65,535 is entered, the keypad will clear the
PIN code entry buffer, generate a beep and is ready to receive a
new 4 digit keypad PIN code.
If the entry of the 1 to 5 digit keypad PIN code is disrupted and no
number key or “ ” key is pressed within 5 seconds, the keypad will
clear the PIN code entry buffer, generate a medium length beep and
is ready to receive a new 1 to 5 digit keypad PIN code.
(EP) FFFF FFFF AAAA AAAA AAAA AAAA (OP)
Where: EP = Even parity for first 12 bits.
OP = Odd parity for last 12 bits.
F = 8-Bit Facility Code.
A = 24-Bit code generated from keyboard.
Sends buffer of 6 keys, adds parity and sends a 26-Bit Binary-
Coded Decimal (BCD) message. Each key is a four bit equivalent of
the decimal number.
The keypad PIN code must be 6 key presses long. On the sixth key
press of the 6 digit PIN code, the data is sent across the Wiegand
Data lines as a BCD message.
If the entry of the 6 digit keypad PIN code is disrupted and no
number key is pressed within 5 seconds, the keypad will clear the
PIN code entry buffer, generate a medium length beep and is ready
to receive a new 6 digit keypad PIN code.
(EP) AAAA BBBB CCCC DDDD EEEE FFFF (OP)
Where:
A = The first key entered. D = Fourth key entered.
B = Second key entered. E = Fifth key entered.
C = Third key entered. F = Sixth key entered.
#
#
6 Keys BCD and parity bits, 26-Bit Wiegand
Page 15 06/01
AY-Q54
Page 14 06/01
AY-Q54
OPTION 5
OPTION 6

This unique mode is intended to let the host controller scan the AY-
Q54’s keypad while still keeping the proximity card readers 26-Bit
Wiegand or Clock & Data formats active.
An optional interface board must be used between the AY-Q54 and
the host system. Each key press is immediately sent on DATA0 as
an ASCII character at a baud rate of 9600 bits per second.
When a key is pressed DATA1 is pulled “low” until the key is
released at which point DATA1 will be set to “high”. This allows the
controller to detect the duration of the key press.
The MD-P64 interface unit outputs the data received to 7 outputs
emulating a keyboard. The interface unit will not effect any data that
it receives from the proximity reader wether it is 26-Bit Wiegand or
Clock & Data.
Key pressed = ASCII Value
0 = ‘0’ ( 0x30 hex ) 6 = ‘6’ ( 0x36 hex )
1 = ‘1’ ( 0x31 hex ) 7 = ‘7’ ( 0x37 hex )
2 = ‘2’ ( 0x32 hex ) 8 = ‘8’ ( 0x38 hex )
3 = ‘3’ ( 0x33 hex ) 9 = ‘9’ ( 0x39 hex )
4 = ‘4’ ( 0x34 hex ) = ‘ ’ ( 0x2A hex )
5 = ‘5’ ( 0x35 hex ) # = ‘#’ ( 0x23 hex )
Buffers up to 8 keys and outputs keypad data without a facility code
like standard Clock and Data card output.
The keypad PIN code can be one to eight digits long. The PIN code
length is selected while programming the reader for Option 8. The
reader will transmit the data when it receives the last key press of
the PIN code. The data is sent across the two data output lines as
binary data in Clock & Data format.
Single Key, 3x4 Matrix Keypad (MD-P64)
1 to 8 Keys BCD, Clock & Data
If the “ “ key or the “ “ key are pressed during PIN code entry, the
keypad will clear the PIN code entry buffer, generate a beep and is
ready to receive a new keypad PIN code.
If the entry of the digit keypad PIN code is disrupted and no number
key or “ ” key is pressed within 5 seconds, the keypad will clear the
PIN code entry buffer, generate a medium length beep and is ready
to receive a new keypad PIN code.
#
#
Page 17 06/01
AY-Q54
Page 16 06/01
AY-Q54
OPTION 7
OPTION 8

Changing the Programming Code
1)
2) "3" Menu 3
3)
4)
Note:
Enter Programming Mode
Press to enter
The Transmit LED will
flash red.
Enter the new 4-digit code
you wish to set as the
Programming Code
System returns to
Transmit Mode
You will hear one beep
The Program LED will turn off
The Transmit LED will turn red
- Programming Code can not be erased, i.e. the code
0000 is not valid and will not erase the Programming
Code.
!
!
!
!
Changing the Facility Code
Return to Factory Default Settings
1)
2) "4" Menu 4
3)
4)
Note:
1)
Enter Programming Mode
Press to enter
The Transmit LED will
flash orange.
Enter the new 3-digit code
you wish to set as
Facility Code
System returns to
Transmit Mode
You will hear one beep
The Program LED will turn off
The Transmit LED will turn red
- Facility codes can be in the range of 000 to 254.
Enter Programming Mode
!
!
!
!
Warning:
You must be very careful before using this command!
Doing so will erase the entire memory which includes
all User and Special Codes, and return all codes to
their factory defaut settings.
Page 19 06/01
AY-Q54
Page 18 06/01
AY-Q54
Transmit Program
GREEN
3
Transmit Program
RED
????
Transmit Program
GREEN
4
Transmit Program
RED
???
Transmit Program
GREEN
RED
Transmit Program
GREEN
ORANGE
Transmit Program
GREEN

2) "0" Menu 0
3)
Press to enter
The Transmit LED will flash red
The Program LED will flash red
Enter your 4-digit Programming
Code.
If the Programming Code is valid, all memory will be erased,
you will hear three beeps and the controller will return to
Normal Mode
If the Programming Code is invalid you will hear a long beep
and the controller will return to Normal Mode without erasing
the memory of the controller.
In the event that the Programming Code is forgotten, the AY-Q54
may be reprogrammed in the field using the following instructions:
!
!
!
!
Replacing a lost Programming Code
1)
2)
3)
4)
Remove power from the reader.
Activate tamper by removing the reader from the wall or removing
the reader’s case.
Apply power to the reader.
You now have 10 seconds to enter Programming Mode using the
factory default Programming Code 1234.
Page 20 06/01
AY-Q54
????
Page 21 08/01
Technical Support
http:///www.rosslare.com.hk/support/
Rosslare Enterprises Ltd.
905-912 Wing Fat Industrial Bldg.,
12 Wang Tai Road, Kowloon Bay,
Hong Kong.
Tel: (852) 2795 5630
Fax: (852) 2795 1508
E-mail: [email protected]
Rosslare Security Products S.r.l
Via F.lli Gabba 5, 20121 Milano, Italy
Tel: (39) 0382 24800
Fax: (39) 0382 24800
E-mail: [email protected]
Rosslare NAPDC
Suite 238, 200 East Howard Street,
Des Plaines, IL 60018
USA
Tel: (847) 827 6330
Fax: (847) 827 5433
E-mail: [email protected]
International Web Site:
Asia, Australia, & South America
Europe, Russia, Middle East, Africa
United States and Canada
:
:
:
AY-Q54
Table of contents