RS PRO RS-136 User manual

Instruction Manual
RS-136
Temperature Calibrator (RTD + TC)

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1
EN 613 6-1 : 013
Please read the statement thoroughly to prevent injury or loss
o li e, and prevent damage to this product.
Earth (ground)
Con orms to relevant European Union
directives.
Do not dispose o this instrument as unsorted
municipal waste. Contact a quali ied
recycler or disposal.
Please remove all the test leads be ore
per orming maintenance, cleaning and
battery rep lacement, etc.

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1
Table o Contents
I.
FEATURES ................................................................................................................ 1
II. PANEL DESCRIPTION ................................................................................................ 2
III. OPERATION ................................................................................................................ 5
3.1
S
OURCE
RTD
SIGNALS
(4W,
3W,
W) .................................................................... 5
3.
S
OURCE
T
HERMOCOUPLE
S
IGNALS
......................................................................... 8
3.3
M
EASURE
RTD
T
EMPERATURE AND
R
ESISTANCE
................................................. 10
3.4
M
EASURE
T
HERMOCOUPLE
T
EMPERATURE
........................................................... 14
3.5
O
PTIMAL
OHM
MEASUREMENT
(4W,
3W,
AND
W) .............................................. 16
3.6
DC
C
URRENT CALIBRATION USING
OHM
MEASUREMENT SETUP
(4,
3,
AND
W) 18
3.7
R
AMP AND
S
TEP IN
SOURCE
MODE
..................................................................... 19
3.8
R
EMOVE
I
NACCURACY CAUSED BY THE RESISTANCE OF TEST LEADS IN
W........ 20
3.9
A
UTO
C
ALIBRATION
................................................................................................ 23
IV. SETUP ........................................................................................................................ 24
4.1
S
ELECT
RTD
TYPE OR RESISTANCE
....................................................................... 25
4.
S
ELECT
TC
TYPE
..................................................................................................... 25
4.3
S
ELECT
UNIT
(℃
OR
℉) ...................................................................................... 26
4.4
E
NTER THE VALUES OF
C
OLD
J
UNCTION
C
OMPENSATION
.................................... 26
4.5
E
NTER THE VALUES OF
RTD
0%
AND
100% ......................................................... 27
4.6
E
NTER THE VALUES OF
TC
0%
AND
100% ............................................................ 27
4.7
A
UTO
-P
OWER
-O
FF
................................................................................................. 28
4.8
R
ESTORE
F
ACTORY
S
ETTINGS
................................................................................ 28
V. ELECTRICAL SPECIFICATIONS ............................................................................ 29
VI. GENERAL SPECIFICATIONS ................................................................................ 37
VII. BATTERY REPLACEMENT ................................................................................. 38
Limited Warranty ....................................................................................................... 39

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
1 03/27/2020 Version No. 1
I. Features
1. High precision and combination o RTD and Thermocouple (TC)
calibration
. Source and measure 14 types o RTD and resistance
3. Source and measure 11 types o thermocouples (TC)
4. 4W, 3W, and 2W connections or RTD simulation and measurement
5. Current calibration o 4 ixed values (100μA, 250μA, 1mA, and 2mA)
6. ℃ and ℉ selectable
7. Accept wide range o excitation current (0.05mA to 5mA) or RTD
simulation
8. Individual Thermocouple cold junction compensation (CJC) or
simulation and measurement o thermocouples. CJC can be used to
ine tune temperature calibration.
9. Easy 0% and 100% setup and operation
10. Easy 25%▲ (up) and 25▼ (down) or temperature calibration.
11. Individual memory o 0% and 100% setup or di erent RTD types
and thermocouple types
1 . Auto step and auto ramp or easy linear calibration
13. Detection o too low or too high excitation current (LO or HI) rom the
measurement device
14. Warning o exceeding calibrator driving current (IEX)
15. Memory o last setup when power o
16. Easy numerical keypad or input
17. Dot Matrix LCD with backlight
18. Very low power consumption o 30mA with backlight o
19. 15 minutes smart auto-power-o . 15 minutes timer resets itsel when
any input changes
0. 2 minutes smart auto-backlight-o . 2 minutes timer resets itsel when
any input changes

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 2
II. PANEL DESCRIPTION
1. ON/OFF button.
2. Backlight
3. SETUP button.
4. M/S button to select Measure or Source
5. Shi t button to select sub- unctions de ined or source. Or enable thermocouple

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
3 03/27/2020 Version No. 1
detection (TCD) or the TC MEASURE mode. In the SETUP, press SHIFT
button to clear the ield or the new data entry.
6. Thermocouple (TC) input and output.
7. Sliding switch or selecting RTD connection 4W, 3W, 2W or thermocouple.
8. Auto step and auto ramp unction or source. Press Shi t irst to select.
9. O set unction to recalibrate calibrator’s o set value.
10. 25%▲(5):
In the SOURCE mode, press SHIFT then 25%▲, calibrator increases output
by 25% o prede ined span o 0% to 100%
In the SETUP, press ▲ to select previous item
25%▼(0):
In the SOURCE mode, press SHIFT then 25%▼, calibrator decreases output
by 25% o prede ined span o 0% to 100%.
In the SETUP, press ▼ to select next item
0 %◄ (7):
In the SOURCE mode, press SHIFT then 0%, calibrator outputs prede ined
0%.
In the SETUP, press ◄ to select the previous option o the item (e.g. RTD or
TC type).
100 %► (9):
In the SOURCE mode press SHIFT then 100%, calibrator outputs prede ined
100%.
In the SETUP, press ► to select the next option o the item (e.g. RTD or TC
type).

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 4
LCD Display
1. Temperature in ℃ or ℉
2. Corresponding Ohm
3. RTD, Resistance or TC type
4. Battery capacity in % (e.g. 57%)
5. RTD connection (4W, 3W, or 2W)
6. SOURCE or MEASURE
7. Lo : Excitation current rom the measuring instrument is too low
Hi: Excitation current rom the measuring instrument is too high
8. IEX: Exceeding calibrator’s driving current
9. TC OK: In MEASURE mode, press SHIFT to enable Thermocouple
Detection (TCD). “TC OK” means no broken wire o thermocouple or
the thermocouple is connected.
TC OPEN: In MEASURE mode, press SHIFT to enable Thermocouple
Detection (TCD). “TC OPEN” means broken wire o thermocouple or
thermocouple is not connected.
10. The calibrator is calibrating itsel . Wait until it is done.

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
5 03/27/2020 Version No. 1
III. OPERATION
3.1 Source RTD signals (4W, 3W, W)

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 6
Step 1: Press M/S button to select SOURCE
Step 2: Move sliding switch to select RTD connection (4W, 3W, or 2W)
Step 3: Press SETUP button to select RTD type. Then press SETUP
button again to exit SETUP
Step 4: Enter value o temperature
Step 5: Connect the calibrator to the instrument under test as shown in
the Figure ollowing

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
7 03/27/2020 Version No. 1
Note: For the SOURCE RTD 3W connection, the two sockets (LO and
sense LO) need to be shorted by the stackable black test leads with
banana plugs (provided). Then plug the test leads with prods into the
stackable test leads.

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 8
3. Source Thermocouple Signals

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
9 03/27/2020 Version No. 1
Step 1: Press M/S button to select SOURCE
Step 2: Move sliding switch to select TC (Thermocouple)
Step 3: Press SETUP button to select TC type. Then press SETUP
button again to exit SETUP
Step 4: Connect the calibrator to the thermometer under test as shown
in the Figure ollowing
Step 5: Enter value o temperature

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 10
3.3 Measure RTD Temperature and Resistance

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
11 03/27/2020 Version No. 1
Step 1: Press M/S button to select MEASURE
Step 2: Move sliding switch to select RTD connection (4W, 3W, or 2W)
Step 3: Press SETUP button to select RTD type. Then press SETUP
button again to exit SETUP
Step 4: Connect the calibrator to the RTD or resistance under test as
shown in the Figure ollowing
Step 5: Read value o temperature or resistance rom LCD

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 12

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
13 03/27/2020 Version No. 1
Note: The inaccuracy caused by the test leads resistance is not included in the
source or measure accuracy.

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 14
3.4 Measure Thermocouple Temperature

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
15 03/27/2020 Version No. 1
Step 1: Press M/S button to select MEASURE
Step 2: Move sliding switch to select TC (Thermocouple)
Step 3: Press SETUP button to select TC type. Then press SETUP
again to exit SETUP
Step 4: Connect the calibrator to the thermocouple under test as
shown in the Figure ollowing
Step 5: Read the value o temperature rom LCD

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
03/27/2020 Version No. 1 16
3.5 Optimal OHM measurement (4W, 3W, and W)
Step 1: Follow the steps stated in section 3.3 and select OHM in the setup.
The calibrator will automatically output optimal current or measurement o
resistance. Users can also press button 5 to enter manual mode and change
the output current (100μA, 250μA, 1mA, and 2mA).

Temperature Calibrator (RTD + TC) / EN
_________________________________________________________________________________
17 03/27/2020 Version No. 1
Step 2: I the other end is another calibrator connected to the calibrator. The
other calibrator might not be able to sense the current outputted rom the
calibrator. Users can press button 5 to enter manual mode and change the
output current. The symbol MAN will be displayed once button 5 is pressed.
Step 3: Press button 5 repeatedly to change the output current until the other
calibrator can sense it. The calibrator will circulate through 4 values o current
(100μA, 250μA, 1mA, and 2mA)
Note: The value o current is displayed at the upper right corner o LCD next
to the MAN symbol.
Table of contents
Other RS PRO Measuring Instrument manuals

RS PRO
RS PRO LCR-6000 Series User manual

RS PRO
RS PRO 232.50.100 User manual

RS PRO
RS PRO RS-96 User manual

RS PRO
RS PRO RS-95 User manual

RS PRO
RS PRO RS-90 User manual

RS PRO
RS PRO RS-8880 User manual

RS PRO
RS PRO ILM 1332A User manual

RS PRO
RS PRO ISM 410 User manual

RS PRO
RS PRO RS-320B User manual

RS PRO
RS PRO IPM 241 User manual

RS PRO
RS PRO 623-883 Manual

RS PRO
RS PRO 236-9298 User manual

RS PRO
RS PRO 123-8776 User manual

RS PRO
RS PRO 1389 User manual

RS PRO
RS PRO RS 1107-UT User manual

RS PRO
RS PRO ISA-730 User manual

RS PRO
RS PRO RSSA3000X User manual

RS PRO
RS PRO ISM 400 User manual

RS PRO
RS PRO RS-8890G User manual

RS PRO
RS PRO RS-1361C User manual