manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. RS PRO
  6. •
  7. Measuring Instrument
  8. •
  9. RS PRO 236-9298 User manual

RS PRO 236-9298 User manual

Other RS PRO Measuring Instrument manuals

RS PRO RS-171V User manual

RS PRO

RS PRO RS-171V User manual

RS PRO ICM A6N User manual

RS PRO

RS PRO ICM A6N User manual

RS PRO RS-9883M User manual

RS PRO

RS PRO RS-9883M User manual

RS PRO RS-95 User manual

RS PRO

RS PRO RS-95 User manual

RS PRO IM-502 User manual

RS PRO

RS PRO IM-502 User manual

RS PRO RSST-2000 Series User manual

RS PRO

RS PRO RSST-2000 Series User manual

RS PRO 123-8776 User manual

RS PRO

RS PRO 123-8776 User manual

RS PRO 2377271 User manual

RS PRO

RS PRO 2377271 User manual

RS PRO RS-3809 User manual

RS PRO

RS PRO RS-3809 User manual

RS PRO IM-740 User manual

RS PRO

RS PRO IM-740 User manual

RS PRO IPM 241 User manual

RS PRO

RS PRO IPM 241 User manual

RS PRO ISM 410 User manual

RS PRO

RS PRO ISM 410 User manual

RS PRO RS-137 User manual

RS PRO

RS PRO RS-137 User manual

RS PRO 877-1791 User manual

RS PRO

RS PRO 877-1791 User manual

RS PRO IM-195 User manual

RS PRO

RS PRO IM-195 User manual

RS PRO 1389 User manual

RS PRO

RS PRO 1389 User manual

RS PRO RS-1340 User manual

RS PRO

RS PRO RS-1340 User manual

RS PRO RSDPB5000 Series User manual

RS PRO

RS PRO RSDPB5000 Series User manual

RS PRO RS 1107-UT User manual

RS PRO

RS PRO RS 1107-UT User manual

RS PRO RS-5322 User manual

RS PRO

RS PRO RS-5322 User manual

RS PRO RS-128M User manual

RS PRO

RS PRO RS-128M User manual

RS PRO RS-1013 User manual

RS PRO

RS PRO RS-1013 User manual

RS PRO RS-1150 User manual

RS PRO

RS PRO RS-1150 User manual

RS PRO RS-1360A User manual

RS PRO

RS PRO RS-1360A User manual

Popular Measuring Instrument manuals by other brands

Powerfix Profi 278296 Operation and safety notes

Powerfix Profi

Powerfix Profi 278296 Operation and safety notes

Test Equipment Depot GVT-427B user manual

Test Equipment Depot

Test Equipment Depot GVT-427B user manual

Fieldpiece ACH Operator's manual

Fieldpiece

Fieldpiece ACH Operator's manual

FLYSURFER VIRON3 user manual

FLYSURFER

FLYSURFER VIRON3 user manual

GMW TG uni 1 operating manual

GMW

GMW TG uni 1 operating manual

Downeaster Wind & Weather Medallion Series instruction manual

Downeaster

Downeaster Wind & Weather Medallion Series instruction manual

Hanna Instruments HI96725C instruction manual

Hanna Instruments

Hanna Instruments HI96725C instruction manual

Nokeval KMR260 quick guide

Nokeval

Nokeval KMR260 quick guide

HOKUYO AUTOMATIC UBG-05LN instruction manual

HOKUYO AUTOMATIC

HOKUYO AUTOMATIC UBG-05LN instruction manual

Fluke 96000 Series Operator's manual

Fluke

Fluke 96000 Series Operator's manual

Test Products International SP565 user manual

Test Products International

Test Products International SP565 user manual

General Sleep Zmachine Insight+ DT-200 Service manual

General Sleep

General Sleep Zmachine Insight+ DT-200 Service manual

Sensa Core Lacto Spark user manual

Sensa Core

Sensa Core Lacto Spark user manual

VOLTCRAFT UTS-1980 operating instructions

VOLTCRAFT

VOLTCRAFT UTS-1980 operating instructions

EBCHQ 94915 Operation manual

EBCHQ

EBCHQ 94915 Operation manual

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Balluff

Balluff BIP LD2-T017-01-EP-S4 Series user guide

Pulsar IMP Lite Series instruction manual

Pulsar

Pulsar IMP Lite Series instruction manual

ETCR 6800 user manual

ETCR

ETCR 6800 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

2.2 Accuracy
Voltage 0.5% of range maximum
Current 0.5% of nominal
Frequency 0.2% of mid-frequency
Power factor 1% of Unity
Active power 1% of range maximum
Reactive power 1% of range maximum
Apparent power 1% of range maximum
Active energy Class 1 IEC62053-21
Class B EN50470-3 (M ID)
Reactive energy 1% of range maximum
2.3 Environment
Operating temperature -25° to +55°
Storage and transportation temperature -40° to +70°
Reference temperature 23° ±2°
Relative humidity 0 to 95%, non-condensing
Altitudeup to 2000m
Warm up time 3s
Mechanical environment M1
Electromagnetic environment E2
Degree of pollution 2
2.4 Mechanics
Din rail dimensions 18x119x62 (WxHxD) DI N 43880
Mounting DI N rail 35mm
Sealing IP51 (indoor)
Material self-extinguishingUL94V-0
3 Display
1
2
Initialization Display
When it is powered on, the meter will initialize and do self-checking.
After the self-checking program, the meter screen will display the total active
energy (kWh)
Scroll Display by button
There is a button on the front of the meter. After initialization and self-checking
program , the meter display the measured values . The default page is total
kWh. If the user wants to check other information, he needs to press the scroll
button on the front panel.
Click the button, the L CD display will scroll the
measurements.
Keep pressing the button for 3 seconds, the meter
will enter set-up mode.
1
1-1
Total active energy(kWh)
Display format:0000.009999.99
10000.099999.90000.00
Import active energy(kWh)
Display format:0000.009999.99
10000.099999.90000.00
Export active energy(kWh)
Display format:0000.009999.99
10000.099999.90000.00
1-2
2Voltage (V)
3Current (A)
4Active power (W)
5Frequency (F)
6
7
Power factor (PF)
8
9
Modbus Address or Primary address
Default: 001
Baudrate Default : 2400bps
Parity
None/Even/Odd are optional
Default: none
10
The display of each model:
3
Software version In kind prevail
Display LCD with white backlit
Max. Reading 99999.9kWh
236-9298 : Total kWh Voltage
Current Power factor
Address
Baudrate
Import kWh Export kWh
Active power Frequency
Parity Software version
Full screen
It will last for 3 seconds.
Software version
It will last for 3 seconds.
Total active energy(kWh)
236-9298
The direct connect type can work with direct load 45A.
236-9298
236-9298
Caution
Qualified personnel
Proper handling
6.2 Installation
ى5mm
5 IN Rail
6.3 Wiring diagram
G B A
7.Declaration of Conformity (for the MID approved version meter only)
Single phase multifunction electrical energy meter “236-9298”,
corresponds to the production model described in the EC-type examination
certificate and to the requirements of the Directive 2004/22/EC EC type
examination certificate number 0120/SGS0585. Identification number
of the NB 0120.
6. Installation
6.1 Safety instruction
Information for your own safety
Warning
5. Dimensions
4. Communication
4.1 Pulse Output
The meter is equipped with 2 pulse outputs, which are fully isolated from
the inside circuit. That generates pulses in proportion to the measured
energy. The pulse outputs are polarity dependent , passive transistor
output requiring an external voltage source for correct operation. For
this external voltage source, the voltage shall be 5-27V DC, and the
maximum input current shall be 27mA DC.
236-9298
ATTENTION:Pulse output must be fed as shown in the
wiring diagram below. Respect polarities
and the connection mode. Opto-coupler with
potential-free SPST-NO Contact.
Contact range:5~27VDC Max.current
Input:27mA DC
+-
Uimp
R
OUTPUT
The meter provides a RS485 port for remote communication. Modbus RTU is the
protocol applied. For Modbus RTU, the following RS485 communication parameters
can be configured from the Set-up menu.
Baud rate: 1200, 2400, 4800, 9600
Parity: NONE/EVEN/ODD
Stop bits:1 or 2
Modbus Address: 1 to 247
4.4 RS485 output for Modbus RTU
4.2 Pulse Output 1
Pulse output 1 is configurable. The pulse output 1 can be set to generate pulses to
represent total / import/ export kWh or kVarh. The pulse constant can be set to
generate 1 pulse per: 0.001 ( default) / 0.01 /0.1 /1kWh /kVarh.
Pulse width: 200 / 100/ 60ms ( default)
4.3 Pulse Output2
Pulse output 2 is non-configurable. It is fixed up with Import kWh. The constant is
1000imp/kWh.
The Pulse width: 60ms
This manual does not contain all of the safety measures for operation of the
equipment(module,device),because special operating conditions,and local
code requirements or regul ation s may necessitate further measures.
However,it does contain informati on whi ch mus t be read for your personal
safety and to avoid material damages.This information is high lighte d by a
warn ing triangle a nd is represente d as foll ows, depending on the degree of
potential danger.
This means that failure to observe the instruction can result in death,
serious injury or considerable material damage.
This m eans ha zard of electric s hock an d failu re to take the
necessary safety precautions will result in death,serious injury or
considerable material damage.
Operation of the equipment (module, device) described in this manual may
only be performed by qualified personnel. Qualified personnel in this m anual
mean s person who are authorized to commission, start up, ground and label
devices,systems and circuits according to safety
and Regulatory standards.
The equipment (device, module) may only be used for the application
specified in the catalogue and the user manual.
Use only insulating tools.
Do not connect while circuit is live (hot).
Place the meter only in dry surroundings.
Do not mount the meter in an explosive area or expose the meter to dust,
mildew and insects.
Make sure the used wires are suitable for the maximum current of this meter.
Make sure the AC wires are connected correctly before activating the
current/voltage to the meter.
Do not connect the meter to a 3 phase - 400VA C - network.
Do not touch the meter connecting clamps directly with your bare
hands, with metal, blank wire or other material as you may get an electrical
shock.
Make sure the protection cover is placed after installation.
Installation, maintenance and reparation should only be done by qualified
personnel.
Never break the seals and open the front cover as this might influence the
functionality of the meter, and will avoid any warranty.
Do not drop, or allow physical impact to the meter as there are high precision
components inside that may break.
Meaning of Symbols
UK conformity markEU conformity mark
FOR MORE INFORMATION VISIT THIS SITE
http://www.rs-components.com/index.html
UK – Birchington Rd, Corby NN17 9RS
EU - Mainzer Landstraße 180. 60327 Frankfurt/Main
The Information contained in these installation instructions is for use only by installers trained
to make electrical power installations and is intended to describe the correct method of
installation for this product. However, Company has no control over the field conditions which
influence product installation.
It is the user's responsibility to determine the suitability of the installation method in the user's
field conditions. Company only obligations are those in Company standard Conditions of Sale
for this product and in no case will Company be liable for any other incidental, indirect or
consequential damages arising from the use or misuse of the products.
FOR MORE INFORMATION VISIT THIS SITE
http://www.rs-components.com/index.html
Measuring Instruments Directive (MID 2014/32/EU).
MID