EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. RS
  6. •
  7. Test Equipment
  8. •
  9. RS UTS-ELS Manual

RS UTS-ELS Manual

This manual suits for next models

1

Other RS Test Equipment manuals

RS 215-6391 Manual

RS

RS 215-6391 Manual

RS 43-114 User manual

RS

RS 43-114 User manual

RS UTS-ISDN User manual

RS

RS UTS-ISDN User manual

RS ISR-6051 User manual

RS

RS ISR-6051 User manual

RS UTS-E Manual

RS

RS UTS-E Manual

RS 487-081 Manual

RS

RS 487-081 Manual

RS ET-5300 User manual

RS

RS ET-5300 User manual

Popular Test Equipment manuals by other brands

SMART KANAAD SBT XTREME 3G Series user manual

SMART

SMART KANAAD SBT XTREME 3G Series user manual

Agilent Technologies BERT Serial Getting started

Agilent Technologies

Agilent Technologies BERT Serial Getting started

Agilent Technologies N3280A user guide

Agilent Technologies

Agilent Technologies N3280A user guide

Lifeloc R.A.D.A.R. quick start guide

Lifeloc

Lifeloc R.A.D.A.R. quick start guide

Fluke T5-600 Service information

Fluke

Fluke T5-600 Service information

Mercury TSL01 user manual

Mercury

Mercury TSL01 user manual

MAHA MBT Series Original operating instructions

MAHA

MAHA MBT Series Original operating instructions

Fuji Electric P-61 instruction manual

Fuji Electric

Fuji Electric P-61 instruction manual

ETC SealerAtor user manual

ETC

ETC SealerAtor user manual

Skyfine ETHYWAY V2 user manual

Skyfine

Skyfine ETHYWAY V2 user manual

Appion G5 Twin Operation manual

Appion

Appion G5 Twin Operation manual

PCB Piezotronics 8159-0112A Installation and operating manual

PCB Piezotronics

PCB Piezotronics 8159-0112A Installation and operating manual

BW Technologies MicroDock II user manual

BW Technologies

BW Technologies MicroDock II user manual

Sun Nuclear 1027 user guide

Sun Nuclear

Sun Nuclear 1027 user guide

Biomark HPR LITE READER user manual

Biomark

Biomark HPR LITE READER user manual

Hioki 3169-20 instruction manual

Hioki

Hioki 3169-20 instruction manual

Ashcroft ATE-100 operating manual

Ashcroft

Ashcroft ATE-100 operating manual

Rohde & Schwarz RTA4000 user manual

Rohde & Schwarz

Rohde & Schwarz RTA4000 user manual

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

Issued 04/1999 V9988
801-544
It is important to take the following precautions when using your UTS-
ELS all weather telephone. This way it gives you a long and trouble free
life.
1. Do not dismantle your UTS, it’s sealed for life.
2. Although the UTS is waterproof it is not submersible and may leak
causing internal damage.
3. Do not stretch the line cord excessively as this may cause the cord
grip to snap.
4. Use the batteries specified, not the zinc carbon type (a suitable
replacement battery is RS stock no. 591-792).
Dialling
UTS automatically selects tone dialling when connected to a line.
RS Stock No.
AC
B
S
213
Batt low
PULSE
LNR
FLASH
MRC
STO
POL
SPKR VOL
9V Alkaline
A
AB
MONITOR
TALK
MUTE
2
ABC
5
JKL
8
TUV
0
OPER
1
4
GHI
7
PRS
3
DEF
6
MNO
9
WXY
#
Batt low
PULSE
LNR
FLASH
MRC STO POL
SPKR VOL
Figures
UTS-ELS All Weather Telephone Test Set
Instruction Leaflet
1
2
3
4
5
This LED near the centre of the keypad will light when the
battery needs replacing.
A suitable replacement battery is RS stock no. 591-792
A. Black wire = tip or +ve terminal
B. Red wire = ring or -ve terminal
C. Cord restraint (if fitted) connect to C
A. Screws (2)
B. Remove cover as shown
Pulse dialling selection
Press PULSE before you go off-hook (press TALK).
You can switch to Tone dialling part way through a call by pressing
*or #(not dialled out).
The dialling mode will not revert to Tone until the line is disconnected
for 1 second
Last number redial
Press LNR.
Flash
Press FLASH.
Program a memory
Go off-hook, press STO, enter the telephone number (or LNR to copy
its contents to a memory) then press STO again, press key (1-9 or 0)
to select the storage location.
Memory dialling
Press MRC then choose the storage location (1-9 or 0).
To use LNR as a Notepad
While off-hook, press STO, enter the digits, press LNR. Previous LNR
content is lost
Loudspeaker facility
When you are waiting for something to happen on the line that may
take some time, it is desirable to have both hands free to work. The
loudspeaker function gives you that freedom. The loudspeaker may be
switched on in the on-hook (monitor) or off-hook (talk) mode.
Loudspeaker-monitor mode
Connect to line, press SPKR to activate. In this mode volume is
needed, press VOL. To reduce volume press again.
Loudspeaker-talk mode
As before but press TALK to seize the line. Dialling is possible with the
loudspeaker on. To speak, press SPKR again and use the handset
normally.
Off-hook (talk)
Press this button to seize the line. Press again or disconnect the line-
cord to go on-hook.
High impedance monitor
Press this button momentarily to monitor the line. Monitor will stay on
while connected to the line and will time-out around 1 minute after
disconnection.
Mute (Tx cut-off)
Press this button to cut-off transmission for privacy or to eliminate
sidetone in noisy areas. Release to talk.
Polarity test/ground start operation
To test polarity connect to the line to be tested. Press the polarity, POL,
button and observe the LEDs (figure 1).
Red LED = Red line cord connection to tip (+ve)
Green LED = Red line cord connection to ring (-ve)
For ground start operation: Connect to line and identify the tip (+ve)
wire. Connect a ground to tip wire. Press TALK and then remove
ground connection.
Changing the battery or line-cord (UTS-ELS is
supplied with a battery)
(see figure 3)
Features and specifications
Tone/pulse (tone priority)
Talk and monitor modes
Last number redial
Ten number memory (24 digits)
Microphone mute
Ringer (sounder)
Monitor impedance >300kΩ
Data-safe monitor
Minimum line current <10mA
Wrap around rubber grip
Waterproof - IP64
Polarity test
Easy battery change
Battery life (alkaline) 2 years typically
Battery low LED
Protected against lightning surges
Time break recall (100ms)
Over-current protected - no repair required
RS Components shall not be liable for any liability or loss of any nature (howsoever
caused and whether or not due to RS Components’ negligence) which may result
from the use of any information provided in RS technical literature.
V9988