Ruijie RG-MUX-8LC Installation and operating manual

Transparent Distribution Device
Hardware Installation and Reference Guide
Document version: 1.1
Date: July 28, 2023
Copyright © 2023 Ruijie
Networks
Copyright
Copyright © 2023 Ruijie Networks
All rights are reserved in this document and this statement.
Any reproduction, excerption, backup, modification, transmission, translation or commercial
use of this document or any portion of this document, in any form or by any means, without the
prior written consent of Ruijie Networks is prohibited.
Trademark and are owned by Ruijie Networks.
All other trademarks or registered trademarks mentioned in this document are owned by
their respective owners.
Disclaimer
The products, services, or features you purchase are subject to commercial contracts and
terms. Some or all of the products, services or features described in this document may not
be within the scope of your purchase or use. Unless otherwise agreed in the contract, Ruijie
Networks does not make any express or implied statement or guarantee for the content of
this document.
Due to product version upgrades or other reasons, the content of this document will be
updated from time to time. Ruijie Networks reserves the right to modify the content of the
document without any notice or prompt.
This manual is for reference only. Ruijie Networks endeavors to ensure content accuracy and
will not shoulder any responsibility for losses and damages caused due to content omissions,
inaccuracies or errors.
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
1
Preface
Intended Audience
This document is intended for:
Network engineers
Technical support and servicing engineers
Network administrators
Technical Support
Ruijie Networks website: https://www.ruijienetworks.com/
Technical support website: https://ruijienetworks.com/support
Case portal: https://caseportal.ruijienetworks.com
Community: https://community.ruijienetworks.com
Technical support email: service_rj@ruijienetworks.com
Live chat: https://www.ruijienetworks.com/rita
Conventions
1. Conventions
Convention
Description
Bold font
Commands, command options, and keywords are in bold
font.
Italic
font
Arguments for which you supply values are in
italic
font.
[ ]
Elements in square brackets are optional.
{ x | y | z }
Alternative keywords are grouped in braces and separated
by vertical bars.
[ x | y | z ]
Optional alternative keywords are grouped in brackets and
separated by vertical bars.
&<1-n>
The argument before the sign (&) can be input for
consecutive 1- n times.
//
Double slashes at the beginning of a line of code indicate a
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
2
comment line.
2. Signs
The signs used in this document are described as follows:
Warning
An alert that calls attention to important rules and information that if not understood or
followed can result in data loss or equipment damage.
Caution
An alert that calls attention to essential information that if not understood or followed can
result in function failure or performance degradation.
Note
An alert that contains additional or supplementary information that if not understood or
followed will not lead to serious consequences.
Specification
An alert that contains a description of product or version support.
3. Note
The manual offers configuration information (including model, port type and command line
interface) for indicative purpose only. In case of any discrepancy or inconsistency between
the manual and the actual version, the actual version prevails.
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
3
1 Introduction to the Transparent Distribution Device
The RG-MUX series transparent distribution devices are passive devices launched by Ruijie
Networks for simplified optical switching. They are applicable to all-optical network
scenarios.
Boasting CWDM technology and standard 16-wavelength ranging from 1271 nm to 1571 nm with
20 nm increments, this series can extend 10G and 1G optical cables to each room when used
with Ruijie Simplified Optical Ethernet (SOE) solution. The core switches integrate functions of
a combiner, reduce the number of occupied ports on the core side, and support virtual
switching unit (VSU) functions. They meet customer requirements for network construction by
replacing combiners, achieving passive distribution nodes, and reducing the configuration and
O&M workloads of active distribution nodes. When a device fault occurs, the impact of its
replacement on the network is minimized for quick network restoration.
Table 1-1 Description
Model
Name
Dimensions (W x D
x H)
RG-MUX-8LC/LC
8-port transparent distribution device on
the building side. A single port supports
1000M and 10G rates.
149 mm x 140.5 mm x
22 mm (5.87 in. x 5.53
in. x 0.87 in.)
RG-MUX-8LC/LC
-H
8-port transparent distribution device on
the building side. A single port supports
1000M and 10G rates. This low-insert-loss
transparent distribution device can be used
with an optical splitter to support dual
uplinks.
149 mm x 140.5 mm x
22 mm (5.87 in. x 5.53
in. x 0.87 in.)
RG-MUX-EXT
Expansion module of the transparent
distribution device on the building side,
which is also an optical splitter. It supports
2:N dual uplinks and is equipped with patch
cables.
149 mm x 140.5 mm x
22 mm (5.87 in. x 5.53
in. x 0.87 in.)
RG-MUX-BOX
Chassis for the transparent distribution
device on the building side with six slots. It
is fit for the 8-port transparent distribution
442 mm x 50 mm x 58
mm (17.4 in. x 1.97 in. x
2.28 in.)
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
4
device or optical splitter.
Caution
The transparent distribution devices must be used with Ruijie CWDM transceivers.
1.1 RG-MUX-8LC/LC
1.1.2 Specifications
Table 1-2 Specifications
Model
RG-MUX-8LC/LC
Description
8-port transparent distribution device on the building side. A single
port supports 1000M and 10G rates.
Center Wavelength
1271 nm to 1571 nm (CWDM)
Channel Spacing
20 nm
Channel Bandwidth
±6 nm
Insertion Loss
< 3.7 dB
Return Loss
> 45 dB
Polarization
Dependent Loss
< 0.3 dB
Adjacent Channel
Isolation
> 25 dB
Non-adjacent
Channel Isolation
> 35 dB
Connector
LC/UPC
Operating
Temperature
0°C to 55°C (32°F to 131°F) at the altitude of 0 m to 1800 m (0 ft. to
5905.51 ft.)
Storage
–40°C to +85°C (–40°F to +185°F)
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
5
Temperature
Operating Humidity
5% RH to 95% RH (non-condensing)
Storage Humidity
5% RH to 95% RH (non-condensing)
Standards
GR-1221-Core and GR-1209-Core
Net Weight
< 0.25 kg (0.55 lbs)
1.1.3 Appearance
Integrating one group of CWDM 16-wavelength passive demultiplexer, RG-MUX-8LC/LC
supports eight access ports and accommodates one input port.
Figure 1-2 RG-MUX-8LC/LC
Figure 1-3 Front Panel
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
6
Figure 1-4 Rear Panel
Figure 1-5 Product Label
1.2 RG-MUX-8LC/LC-H
1.2.1 Specifications
Table 1-3 Specifications
Model
RG-MUX-8LC/LC-H
Description
8-port transparent distribution switch on the building side. A single
port supports 1000M and 10G rates.
Center Wavelength
1271 nm to 1571 nm (CWDM)
Channel Spacing
20 nm
Channel Bandwidth
±6 nm
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
7
Insertion Loss
< 2.6 dB
Return Loss
> 45 dB
Polarization
Dependent Loss
< 0.3 dB
Adjacent Channel
Isolation
> 25 dB
Non-adjacent
Channel Isolation
> 35 dB
Connector
LC/UPC
Operating
Temperature
–0°C to 55°C (32°F to 131°F, altitude: 0 ft. to 5905.51 ft.)
Storage
Temperature
–40°C to +85°C (–40°F to +185°F)
Operating Humidity
5% RH to 95% RH (non-condensing)
Storage Humidity
5% RH to 95% RH (non-condensing)
Standard
GR-1221-Core and GR-1209-Core
Net Weight
< 0.25 kg (0.551 lbs)
1.2.2 Appearance
Integrating one group of CWDM 16-wavelength passive demultiplexer, RG-MUX-8LC/LC-H
supports eight access ports, and has one input port with low insertion loss.
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
8
Figure 1-6 RG-MUX-8LC/LC-H
Figure 1-7 Front Panel
Figure 1-8 Rear Panel
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
9
Figure 1-9 Product Label
1.3 RG-MUX-EXT
1.3.1 Specifications
Table 1-4 Specifications
Model
RG-MUX-EXT
Description
Expansion module of the transparent distribution device on the
building side, which is also an optical splitter. It supports 2:N dual
uplinks and is equipped with patch cables.
Wavelength Range
1271 nm to 1571 nm
Channel Spacing
20 nm
Channel Bandwidth
±6 nm
Insertion Loss
< 4.2 dB
Return Loss
> 45 dB
Polarization
Dependent Loss
< 0.3 dB
Connector
LC/UPC
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
10
Operating
Temperature
0°C to 55°C (32°F to 131°F, altitude: 0 ft. to 5905.51 ft.)
Storage
Temperature
–40°C to +85°C (–40°F to +185°F)
Operating Humidity
5% RH to 95% RH (non-condensing)
Storage Humidity
5% RH to 95% RH (non-condensing)
Standard
GR-1221-Core and GR-1209-Core
Net Weight
< 0.15 kg (0.33 lbs)
1.3.2 Appearance
The RG-MUX-EXT is applied to VSU scenarios, providing two uplink output ports.
Figure 1-10 RG-MUX-EXT
Installation location: standard 19-inch rack on the building side. Wall-mounting is also
supported.
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
11
Figure 1-11 Front Panel
Figure 1-12 Rear Panel
Figure 1-13 Product Label
1.4 RG-MUX-BOX
1.4.1 Specifications
Table 1-5 Specifications
Model
RG-MUX-BOX
Description
Chassis for transparent distribution device on the building side
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
12
with six slots, which is fit for 8-port transparent distribution device
or splitter.
Operating
Temperature
–40°C to +85°C (–40°F to +185°F)
Storage
Temperature
–40°C to +85°C (–40°F to +185°F)
Operating Humidity
5% RH to 95% RH
Storage Humidity
5% RH to 95% RH
Net Weight
0.9 kg (1.98 lbs)
1.4.2 Appearance
The chassis is suitable for the transparent distribution device and optical splitter. It requires a
19 RU rack for installation. The chassis is accompanied by a filler panel. Remove the filler
panel from the chassis, and then install the transparent distribution device or optical splitter.
Figure 1-14RG-MUX-BOX
Installation location: standard 19-inch rack on the building side. Wall-mounting is also
supported.
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
13
Figure 1-15 Front Panel
Figure 1-16 Rear Panel
Figure 1-17 Product Label
1.5 CWDM Transceivers
Note
CWDM transceivers on the core side are used with the corresponding switch, while
access CWDM transceivers are used with transparent distribution device and access
switch.
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
14
The number of access CWDM transceiver module must match the port number of the
transparent distribution device. For instance, the CWDM transceiver of Access 1 should
be connected to Output Port 1 of the corresponding transparent distribution device.
Note
The CWDM transceivers (SFG-LR-SM and SFX-LR-SM) on the core side, should be plugged
into the core switch in the core equipment room, and be connected to the transparent
distribution device installed in the weak power room of the building through the input port.
1.5.1 SFG-LR-SM
The SFG 1G CWDM transceiver is on the core side with simplex and single-mode optical cable.
The optical cable is 10 km (6.21 mi.) long and supports eight wavelengths for eight access
devices, using LC connector.
1.5.2 SFX-LR-SM
The SFX 10G CWDM transceiver is on the core side with simplex and single-mode optical cable.
The optical cable is 10 km (6.21 mi.) long and supports eight wavelengths for eight access
devices, using LC connector.
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
15
1.5.3 GE-SFP-LR(A1-8)-H
The GE-SFP-LR(A1-8)-H is a group of eight high-power 1G CWDM transceivers on the access
side with eight wavelengths and single-mode optical cables. The optical cables are 10 km (6.21
mi.les) long, using LC connector.
The eight CWDM transceivers are listed below:
Series
SFP Model
Label
Rate
GE-SFP-LR(A1-8)-H
GE-SFP-LR-SM1431-A1-H
Access 1
1 Gbps
GE-SFP-LR-SM1451-A2-H
Access 2
1 Gbps
GE-SFP-LR-SM1471-A3-H
Access 3
1 Gbps
GE-SFP-LR-SM1491-A4-H
Access 4
1 Gbps
GE-SFP-LR-SM1511-A5-H
Access 5
1 Gbps
GE-SFP-LR-SM1531-A6-H
Access 6
1 Gbps
GE-SFP-LR-SM1551-A7-H
Access 7
1 Gbps
GE-SFP-LR-SM1571-A8-H
Access 8
1 Gbps
1.5.4 GE-SFP-LR(A1-4)-H
The GE-SFP-LR(A1-4)-H is a group of four high-power 1G CWDM transceivers on the access
side with four wavelengths and single-mode optical cables. The optical cables are 10 km (6.21
miles) long, using the LC connector.
Four CWDM transceivers are listed below:
Series
SFP Model
Label
Rate
GE-SFP-LR(A1-4)-H
GE-SFP-LR-SM1431-A1-H
Access 1
1 Gbps
GE-SFP-LR-SM1451-A2-H
Access 2
1 Gbps
GE-SFP-LR-SM1471-A3-H
Access 3
1 Gbps
GE-SFP-LR-SM1491-A4-H
Access 4
1 Gbps
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
16
1.5.5 XG-SFP-LR(A1-8)-H
The XG-SFP-LR(A1-8)-H is a group of eight high-power 10G CWDM transceivers on the access
side, with eight wavelengths and single-mode optical cables. The optical cables are 10 km
(6.21 miles) long, using the LC connector.
Eight CWDM transceivers are listed below:
Series
SFP+ Model
Label
Rate
XG-SFP-LR(A1-8)-H
XG-SFP-LR-SM1431-A1-H
Access 1
10 Gbps
XG-SFP-LR-SM1451-A2-H
Access 2
10 Gbps
XG-SFP-LR-SM1471-A3-H
Access 3
10 Gbps
XG-SFP-LR-SM1491-A4-H
Access 4
10 Gbps
XG-SFP-LR-SM1511-A5-H
Access 5
10 Gbps
XG-SFP-LR-SM1531-A6-H
Access 6
10 Gbps
XG-SFP-LR-SM1551-A7-H
Access 7
10 Gbps
XG-SFP-LR-SM1571-A8-H
Access 8
10 Gbps
1.5.6 XG-SFP-LR(A1-4)-H
The XG-SFP-LR(A1-4)-H is a group of four high-power 10G CWDM transceivers on the access
side, with four wavelengths and single-mode optical cables. The optical cables are 10 km (6.21
mi.) long, using LC connector.
The four CWDM transceivers are listed below:
Series
SFP+ Model
Label
Rate
XG-SFP-LR(A1-4)
-H
XG-SFP-LR-SM1431-A1-H
Access 1
10 Gbps
XG-SFP-LR-SM1451-A2-H
Access 2
10 Gbps
XG-SFP-LR-SM1471-A3-H
Access 3
10 Gbps
XG-SFP-LR-SM1491-A4-H
Access 4
10 Gbps
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
17
XG-SFP-LR-SM1511-A5-H
Access 5
10 Gbps
XG-SFP-LR-SM1531-A6-H
Access switch 6
10 Gbps
XG-SFP-LR-SM1551-A7-H
Access 7
10 Gbps
XG-SFP-LR-SM1571-A8-H
Access 8
10 Gbps
1.5.7 XG-SFP-LR(A1-8)
The XG-SFP-LR(A1-8) is a group of eight low-power 10G CWDM transceivers on the access
side, with eight wavelengths and single-mode optical cables. The optical cables are 10 km
(6.21 miles) long, using LC connector.
Eight CWDM transceivers are listed below:
Series
SFP+ Model
Number
Rate
XG-SFP-LR(A1-8)
XG-SFP-LR-SM1431-A1
Access 1
10 Gbps
XG-SFP-LR-SM1451-A2
Access 2
10 Gbps
XG-SFP-LR-SM1471-A3
Access 3
10 Gbps
XG-SFP-LR-SM1491-A4
Access 4
10 Gbps
XG-SFP-LR-SM1511-A5
Access 5
10 Gbps
XG-SFP-LR-SM1531-A6
Access 6
10 Gbps
XG-SFP-LR-SM1551-A7
Access 7
10 Gbps
XG-SFP-LR-SM1571-A8
Access 8
10 Gbps
1.5.8 XG-SFP-LR(A1-4)
The XG-SFP-LR(A1-4) is a group of low-power 10G CWDM transceivers on the access side
with four wavelengths and single-mode optical cables. The optical cables are 10 km (6.21 mi.)
long, using the LC connector.
Four CWDM transceivers are listed below:
Hardware Installation and Reference Guide Introduction to the Transparent Distribution Device
18
Series
SFP+ Model
Number
Rate
XG-SFP-LR(A1-4)
XG-SFP-LR-SM1431-A1
Access 1
10 Gbps
XG-SFP-LR-SM1451-A2
Access 2
10 Gbps
XG-SFP-LR-SM1471-A3
Access 3
10 Gbps
XG-SFP-LR-SM1491-A4
Access 4
10 Gbps

This manual suits for next models

1

Other Ruijie Network Hardware manuals

Ruijie RG-S6980-64QC Installation and operating manual

Ruijie

Ruijie RG-S6980-64QC Installation and operating manual

Ruijie Reyee RG-EST100-E Installation and operating manual

Ruijie

Ruijie Reyee RG-EST100-E Installation and operating manual

Ruijie Reyee RG-EST Series User manual

Ruijie

Ruijie Reyee RG-EST Series User manual

Ruijie RG-WS6512-L Installation and operating manual

Ruijie

Ruijie RG-WS6512-L Installation and operating manual

Ruijie RG-EST310 Series Installation and operating manual

Ruijie

Ruijie RG-EST310 Series Installation and operating manual

Ruijie RG-WALL 1600-Z3200-S Installation and operating manual

Ruijie

Ruijie RG-WALL 1600-Z3200-S Installation and operating manual

Ruijie Reyee RG-EST Series How to use

Ruijie

Ruijie Reyee RG-EST Series How to use

Ruijie RG-EST350 Series Installation and operating manual

Ruijie

Ruijie RG-EST350 Series Installation and operating manual

Ruijie Reyee RG-EST Series Dimensions

Ruijie

Ruijie Reyee RG-EST Series Dimensions

Ruijie Reyee RG-EST100-E User manual

Ruijie

Ruijie Reyee RG-EST100-E User manual

Ruijie Reyee RG-NBR6215-E User manual

Ruijie

Ruijie Reyee RG-NBR6215-E User manual

Ruijie Reyee RG-EST Series User manual

Ruijie

Ruijie Reyee RG-EST Series User manual

Ruijie Reyee RG-EST310 Installation and operating manual

Ruijie

Ruijie Reyee RG-EST310 Installation and operating manual

Ruijie RG-WALL1600-S3200 Installation and operating manual

Ruijie

Ruijie RG-WALL1600-S3200 Installation and operating manual

Popular Network Hardware manuals by other brands

evertz TR-3200E user manual

evertz

evertz TR-3200E user manual

AIVO NETWORKS ANCP3005Q installation guide

AIVO NETWORKS

AIVO NETWORKS ANCP3005Q installation guide

TP-Link GPON OLT P1200-08 Configuration guide

TP-Link

TP-Link GPON OLT P1200-08 Configuration guide

Digiever DS-2000 Series user manual

Digiever

Digiever DS-2000 Series user manual

Cabletron Systems 9C300-1 Upgrade instructions

Cabletron Systems

Cabletron Systems 9C300-1 Upgrade instructions

Axis 25258R3 Benutzerhandbuch

Axis

Axis 25258R3 Benutzerhandbuch

FITRE RETEMATIC IP-RMH1 Installation & configuration manual

FITRE

FITRE RETEMATIC IP-RMH1 Installation & configuration manual

AVE Video Serial Synchronous ATM Interface... Operation manual

AVE

AVE Video Serial Synchronous ATM Interface... Operation manual

Z-Wave RAZBERRY 7 PRO quick start guide

Z-Wave

Z-Wave RAZBERRY 7 PRO quick start guide

Panasonic Transistors 2SC3930G Specifications

Panasonic

Panasonic Transistors 2SC3930G Specifications

Anritsu CMA5000a Product brochure

Anritsu

Anritsu CMA5000a Product brochure

Positron FS-GIGA Quick installation guide

Positron

Positron FS-GIGA Quick installation guide

Iomega px Series quick start guide

Iomega

Iomega px Series quick start guide

Cudy GS1005P user manual

Cudy

Cudy GS1005P user manual

Nace Security Tronix Fit ST-NVR4/8CH-F quick start guide

Nace

Nace Security Tronix Fit ST-NVR4/8CH-F quick start guide

Fortinet FortiDB-400B quick start guide

Fortinet

Fortinet FortiDB-400B quick start guide

NETGEAR UTM25-100NAS - Prosecure Utm Appliance 25U No Sub... Reference manual

NETGEAR

NETGEAR UTM25-100NAS - Prosecure Utm Appliance 25U No Sub... Reference manual

Covaris R230 Setup & instruction manual

Covaris

Covaris R230 Setup & instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.