manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Salus
  6. •
  7. Thermostat
  8. •
  9. Salus VS35W User manual

Salus VS35W User manual

Other manuals for VS35W

3

This manual suits for next models

1

Other Salus Thermostat manuals

Salus VS30W User manual

Salus

Salus VS30W User manual

Salus ERT20RF User manual

Salus

Salus ERT20RF User manual

Salus RT500BC User manual

Salus

Salus RT500BC User manual

Salus CT100 User manual

Salus

Salus CT100 User manual

Salus SQ605RF User manual

Salus

Salus SQ605RF User manual

Salus RT310RF User manual

Salus

Salus RT310RF User manual

Salus ST620RF User manual

Salus

Salus ST620RF User manual

Salus ERT50 User manual

Salus

Salus ERT50 User manual

Salus RT 10 User manual

Salus

Salus RT 10 User manual

Salus 091FLRF User manual

Salus

Salus 091FLRF User manual

Salus QUANTUM SQ610RF User manual

Salus

Salus QUANTUM SQ610RF User manual

Salus VS10WRF User manual

Salus

Salus VS10WRF User manual

Salus RT510 User manual

Salus

Salus RT510 User manual

Salus RT510 User manual

Salus

Salus RT510 User manual

Salus RT310iSPE User manual

Salus

Salus RT310iSPE User manual

Salus VS35W User manual

Salus

Salus VS35W User manual

Salus VS20WRF User manual

Salus

Salus VS20WRF User manual

Salus CT100 User manual

Salus

Salus CT100 User manual

Salus ST620 Owner's manual

Salus

Salus ST620 Owner's manual

Salus HTRP24 User manual

Salus

Salus HTRP24 User manual

Salus VS20WRF User manual

Salus

Salus VS20WRF User manual

Salus AS20WRF User manual

Salus

Salus AS20WRF User manual

Salus HTRS230V(30) User manual

Salus

Salus HTRS230V(30) User manual

Salus RT200 User manual

Salus

Salus RT200 User manual

Popular Thermostat manuals by other brands

Full Gauge TIC-17C product manual

Full Gauge

Full Gauge TIC-17C product manual

Imit Chronomix S manual

Imit

Imit Chronomix S manual

ChiliTec ST-35 ana instruction manual

ChiliTec

ChiliTec ST-35 ana instruction manual

Azel D-500 user guide

Azel

Azel D-500 user guide

Honeywell Chronotherm III owner's manual

Honeywell

Honeywell Chronotherm III owner's manual

Charmeg MP-R user manual

Charmeg

Charmeg MP-R user manual

dixell WING XW40LS Installing and operating instructions

dixell

dixell WING XW40LS Installing and operating instructions

Network Thermostat NetX X7C-WIFI Installation and programming manual

Network Thermostat

Network Thermostat NetX X7C-WIFI Installation and programming manual

Radio Thermostat CT80 Operation guide

Radio Thermostat

Radio Thermostat CT80 Operation guide

HAI Omnistat RC-120 installation manual

HAI

HAI Omnistat RC-120 installation manual

Lennox iComfort E30 Installation and setup guide

Lennox

Lennox iComfort E30 Installation and setup guide

Lux Products PSD011Ba Installation and operating instructions

Lux Products

Lux Products PSD011Ba Installation and operating instructions

Computherm Q20 operating instructions

Computherm

Computherm Q20 operating instructions

Heatmiser neoStat user manual

Heatmiser

Heatmiser neoStat user manual

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

Mars

Mars HEAT CONTROLLER IR Wireless Thermostat user manual

LUX LP0511D user manual

LUX

LUX LP0511D user manual

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Saswell

Saswell SAS920XWHB-7-S-RF User manual and warranty card

Aircalo TFP1-ET85P2 operating manual

Aircalo

Aircalo TFP1-ET85P2 operating manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

L
VS35
L NSLS1 S2 NSB
INPUT
N
M
T
AC 230V
Note: Use the rear plate of theVS35 thermostat only with this model.
Note: In the KL06 wiring centre, the SL terminal is marked with an arrow
icon .
Installation Manual
Wired thermostat with digital display for the control
of temperature in UFH & RAD systems
Model: VS35W (white), VS35B (black)
Introduction
The VS35 thermostat controls temperatures of individual heating zone
in underoor heating systems. Thermostat allows for signicant savings
thanks to the possibility of maximum reduction the set temperature.
The full version of the manual in PDF format is available on the website
www.salus-controls.eu
Introduction
This product complies with the following EU Directives: Electromagnetic
Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU and RoHS
2011/65/EU. Full information is available on the website www.saluslegal.com
Safety Information
Use in accordance with national and EU regulations. Use the device only as
intended, keeping it in a dry condition. The product is for indoor use only.
Installation must be carried out by a qualied person in accordance with
national and EU regulations.
Terminals description
Terminal Description
L,N Power Supply 230 V AC
NSB Night SetBack (input 230 V AC)
SL Switched output (230V AC)
S1, S2 External temperature sensor
Proper thermostat placement
LCD Icon description Wiring diagrams
Installation
MM
150 cm
min 20 cm
Button Function
Increasing / decreasing temperature or value
Selection of the operating mode, switching between values
Short press - selection conrmation
Long press - entry to or exit from the menu
Long press causes blocking or unlocking the thermostat
+
Button Functions
2 3 4 5 6
7
8
9
10
11
12
13
14
1
1. Current active mode
2. Comfort mode
3. Standard mode
4. Economic mode
5. Automatic mode
6. Frost protection mode
7. Temperature unit
8. Manual mode / temp. override
9. Current / set temperature
10. Key lock
11. Settings
12. Additional temperature sensor
13. Cooling
14. Heating
Importer:
SALUS Controls plc
Salus House
Dodworth Business Park
Whinby Road,
Barnsley S75 3SP,
United Kingdom
DISTRIBUTOR
OF SALUS CONTROLS:
QL CONTROLS Sp. z o.o., Sp. k.
Rolna 4,
43-262 Kobielice,
Poland
www.salus-controls.eu
SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development SALUS Controls plc reserve the right to
change specification, design and materials of products listed in this brochure without prior notice.
VS35 thermostat in connection with actuator or pump
OR
VS30 thermostat in connection with a boiler with a “NO”voltage free
terminal through the RM-16A relay
VS35 thermostat in connection with wiring centre
VS35
L
L
N
N
LN
SL
SL
S1 S2 NSB
INPUT
T
LNSL
KL08NSB
KL06
VS30
L NSLS1 S2 NSB
OUTPUT
T
L
N
AC 230V
In this diagram, the VS30 thermostat manages the NSB function,
more details about NSB function can be found on the next page.
NSB function and an additional temperature sensor is optional.
The VS35 thermostat has been designed for ush mounting in
a standard electrical box with a diameter of 60 mm.
L
AC 230V
VS35
RM-16A
L
NO
COM
INPUT 230 V AC
OUTPUT
POWER SUPPLY
230 V AC/ 50 Hz
NC
SL
N
L
NSLS1 S2 NSB
INPUT
N
T
1 2
3
An additional temperature sensor is optional.
T
T
VII 2017
Temperature setting
Manual mode - temperature settings
NSB function - automatic mode
Changing the HEATING / COOLING mode
Oset function (temperature calibration)
Installer settings
Error codes
dxx Function Value Description Default
value
d01 Control method
temperature
0 PWM algorithm
0
1 Span ±0.5°C
2 Span ±1.0°C
d02 Oset temperature from -3.0°C
to +3.0°C
If the thermostat indica-
tes wrong temperature,
you can correct
it by ± 3.0°C
0°C
d03
Using a oor
temperature sensor
(S1, S2)
0 No sensor
0
1 Sensor is connected
d04
External sensor
used for air
or oor temperature
measurement
(Function is active,
when d03=1)
0
Thermostat measures
the temperature only on
the external sensor 0
1
The sensor is used
as a protection against
overheating the oor
d05 Cooling mode control
method
1 Span ±0.5°C 2
2 Span ±1.0°C
d06 Type of thermoelectric
actuator
0 NO - normally open 1
1NC - normally closed
d07 Valve protection 0 OFF 1
1 ON
d08 Frost protection
temperature 5-17°C Frost protection / Holiday
mode temperature 5°C
d12 Heating temperature
limit 5-35°C
The maximum heating
temperature that can be set
by the user
35°C
d13 Cooling temperature
limit 5-40°C
The minimum cooling
temperature that can
be set by the user
5°C
d14
Maximum oor
temperature
(this function is active
in heating mode when
d04 = 1)
6-45°C
In order to protect the
oor from overheating,
heating will be turned
OFF, when the maximum
temperature of the oor
sensor will be reached
27°C
d15
Minimum oor
temperature
(this function is active
in heating mode when
d04 = 1)
6-45°C
In order to protect
the oor, heating will
be turned ON, when the
minimum temperature
of the oor sensor will
be reached
10°C
d16
Lower oor temperature
limit for cooling
(this function is active
when d04 = 1)
6-45°C
In order to protect the
oor, cooling will
be turned OFF, when
the minimum temperatu-
re will be reached
6°C
d18 Operating mode
HEATING / COOLING
0Heating system 0
1Cooling system
Error code Description
Err02 The maximum / minimum oor temperature has been exceeded
Err03 Temperature sensor is faulty
Err04 Temperature sensor is shorted
1
4
3 sec
3 sec
3 sec
1
5
2
43
3 sec
Choose mode
using or buttons.
1 2
43
3 sec
Set Oset temperature value
using or buttons.
Set the temperature with
or buttons.
Select the service parameter
using or buttons.
The parameter value
is set by or .
Press to conrm the changes.
Simultaneously hold the buttons
for 3 seconds.
Press to conrm the changes.
Press to conrm the changes.
Current temperature. Temperature set in the selected
operating mode.
Choose the temperature mode
using or buttons.
Select the automatic mode
using or buttons.
Press to conrm the changes.
Press any button to highlight the screen, then follow the steps below:
Press any button to highlight the screen, then follow the steps below:
Press any button to highlight the screen, then follow the steps below:
Press any button to highlight the screen, then follow the steps below:
Press any button to highlight the screen, then follow the steps below:
There are 4 temperature levels available. In manual mode only one
temperature level is active (icon in the frame indicates which mode is
currently choosen). For each temperature levels you can set a dierent
temperature.
The NSB (Night SetBack) function can automatically change temperatures
on VS35 daily thermostats via VS30 programmable thermostat connected to
a wiring centre (or another external clock). NSB function switches between
comfortable temperature and economic temperature .
TheVS35 thermostat allows you to adjust the displayed temperature ± 3.0°C.
You can do it according to the following steps:
To activate the automatic mode, select the icon. On display together with
the icon, the controller indicates active temperature mode: or .
- Comfort mode
- Standard mode
- Economic mode
- Frost protection mode. Usually used in a longer period of absence
or during the holidays (available only in heating mode).
Press any button to highlight the screen, then follow the steps below:
Note: You can also set the Oset temperature value using the service
parameter d02.
Note: For the NSB function to work, it is necessary to connect the wirings
properly. Connection diagrams can be found on the previous page.
2
3
Note: To restore the thermostat’s factory settings, in step 2 set the PSuu
to 47 code, and conrm the selection with the button.
Note: Heating / cooling mode can also be set using the service parameter
d18.
2
2
1
1
1
2
34