PAGE 01
KEEP THIS INSTRUCTION BOOKLET FOR FUTURE REFERENCE
PLEASE READ THE INSTRUCTIONS COMPLETELY
BEFORE BEGINNING THE INSTALLATION.
This is a general installation instruction
for the following collections:
* Monza
* Novo
Pressure Balanced Shower
7”
3.750"
1.913"
0.188"
DESCRIPTION
This product is precision engineered to provide satisfactory performance provided it is installed and operated in
accordance with our recommendations contained in this manual. In order to fully enjoy the comfort, safety and the
reliability of your pressure balancing valve, be certain to familiarize yourself with the contents of this manual.
SPECIFICATIONS AND DIMENSIONS
Minimum operating pressure 20 psi
Maximum operating pressure 145 psi
Maximum test pressure 500 psi
Hot and cold water inlets ½" IPS
Shower outlet ½" IPS
Flow capacity 5 USGPM @ 50 psi
Finished wall adjustment : see Illustration B
INSTALLATION
NOTE: Failure to follow these instructions may cause damage or improper operations and nullify the warranty.
ROUGH IN
- Make sure the water supplies are off.
- Remove all the trim items (plate, handle and flange) before installation.
- Secure the valve firmly against the stud. Make sure the ½" shower outlet is in the up position.
- Make sure to flush or raise grouting on the tiled wall surface.
- Adjust the All Thread depth against the Teflon Washer and Limit Stop.
Screw the All Thread against the Teflon washer until it is pressured gently against each other.
- Tighten firmly the Lock Nut against the Lock Plate.
- Position the valve using the dimension shown in the illustration B.
INSTALLATION INSTRUCTIONS
LOCK NUT
LEVER PLUG O-RING
HANDLE ASSEMBLY
Trim Plate
ILLUSTRATION B PAGE 02
WALL LINE
46"
78"
(1981 mm)
FLOOR
LINE
3. 25”
All Thread
Stem
Lock Nut
Lock Plate
center of inlet nished wall
Pressure Balanced Shower
PLASTIC WASHER SET SCREW
VENT PLUG
TRIM INSTALLATION
- Place the shower plate on the all thread
- Secure the plate by inserting plastic washer and lock nut onto
all thread and make sure that the plate is secured..
- Thread the handle set with the washer and adapter onto all thread
with the stem and mark the position.
- Take off the handle assembly and cut off the excess thread and stem.
- Keeping the handle set at 6 o’clock position, thread handle assembly
onto all thread by using escutcheon being caution not to over tighten.
- Tightening the set screw using the allen key and insert the o-ring
and vent plug to cover the hole.
INSTALLATION INSTRUCTIONS
All Thread
Lock Nut
Lock Plate
LOCK NUT HANDLE ASSEMBLY
Trim Plate
Stem
PAGE 03
C OLD
WARM
WARMER
HOT
ILLUSTRATION C
PM-280 - SERVICE VALVE (OPTIONAL)
VALVE CARTRIDGE - TE010
MECHANICAL STOP- TE013
LIMIT STOP- TE014
PM-007-1 - STEM
TEFLON WASHER
PM-009 - LOCK PLATE
PM-012 - LOCK NUT
PM-011 - ALL THREAD
FILTER SCREEN - Te012
Pressure Balanced Shower
PLASTIC WASHER
TROUBLE SHOOTING
MALFUNCTION CAUSE REMEDY
Shower control opening through hot.
Tub filler or Shower head drips after
shutting off the valve.
Shower insufficiently hot.
No flow of hot or cold water.
Valve body too deep into
the wall.
- Hot and cold water supplies have been connected
in reverse
- Water remains in the piping column to the shower
head (this is normal).
- Incorrect setting of the mechanical stop against the
stop post causing a partially opened cartridge.
- O-ring seal on the inlet of the cartridge is faulty.
- Adjustable handle position stop incorrectly set.
- Either the hot or cold side is not fully pressurized.
- Debris caught inside the inlet of the cartridge.
.
- The measured rough in or finished wall surface is
incorrect.
Rotate cartridge
- Allow approximately 3-5 minutes to drain column.
- Reset the mechanical stop as described in this page
- Check O-ring for cut or damage and replace if necessary.
- Check hot water source temperature setting.
- Be sure service stops (when applicable) are both wide open
and system is fully pressurized.
- Remove cartridge and flush out or remove any debris lodged
inside the hot or cold inlet.
install the extension kit.
PM460X(long sleeve).
PM461X (long plastic upper link)
NOTE: AT NO TIME TRY TO STOP DRIPPING BY APPLYING EXTREME FORCE WHEN CLOSING THE VALVE.
O-RING
FILTER
INLET
FILTER INSERT
VALVE
FILTER SCREEN REMOVAL AND CLEANING
The valve has filter screens that prevent debris from obstructing the pressure balancing cartridge.
If excessive in-line debris accumulates in the filter screen you will notice a decrease in flow from the valve.
PLEASE NOTE - SHUT OFF BOTH HOT AND COLD WATER SUPPLIES BEFORE SERVICING VALVE.
- The filter screen are attached to an insert that is fitted into the valve body inlets.
With the cartridge removed the 2 inserts and filter screens can be easily removed from the valve body.
- Remove the insert by pressing the top corner. This will rotate the insert allowing easy removal.
- There is a place on either side of the filter insert where you can get your finger nail underneath the filter screen.
By pulling the filter screen away from the insert it will "pop out".
- All debris can be now be easily removed from the filter screen.
Replace the filter screen into the insert and push together gently until it clicks into place.
- Place the insert back into the valve body, making sure the angled edge of the insert faces out.
The insert should sit flush against the wall of the valve body when properly installed.
Santec Inc.
3501 Challenger Street, Torrance, CA 90503
Tel: (310) 542-0063 Fax (310) 542-5681
www.santecfaucet.com 10/07
STOP POST
Illustration D1
Illustration D2
MECH ANICA L STOP
STOP POST
LIMIT STOP
LIMIT STOP
TEMPERATURE LIMIT STOP SET UP
-Santec Pressure Balanced Valve has a temperature limit stop ( please see Illustration C)
which once set properly can provide a safe and comfortable hot water.
Below is the limit stop installation procedure:
- Remove all Handle trim parts, including the trim plate.
- remove all internal parts up to the Limit Stop, do not remove the Mechanical Stop.
After Mechanical Stop is removed please follow the instruction bellow
- Turn the cartridge clockwise until it is stopped. Do not force to avoid damaging the cartridge.
- Insert the Mechanical Stop onto the cartridge
- Turn the cartridge counterclockwise to open the water line. Turn until it reaches the maximum
hot water desired by the user.
- Place Limit Stop as shown in the Illustration D2.
- Reinstall all the parts accordingly to the Illustration C.
MECH ANICA L STOP
INSTALLATION INSTRUCTIONS
PAGE 04
Pressure Balanced Shower

This manual suits for next models

18

Other Santec Bathroom Fixture manuals

Santec ALEXIS 2320HA User manual

Santec

Santec ALEXIS 2320HA User manual

Santec METRA E Series User manual

Santec

Santec METRA E Series User manual

Santec ESTATE Series User manual

Santec

Santec ESTATE Series User manual

Santec KLASSICA 9565KL User manual

Santec

Santec KLASSICA 9565KL User manual

Santec Novo 2835EM-TM User manual

Santec

Santec Novo 2835EM-TM User manual

Santec HANA 4166TR Series User manual

Santec

Santec HANA 4166TR Series User manual

Santec KRISS 2220CN User manual

Santec

Santec KRISS 2220CN User manual

Santec Klassica 70847410 User manual

Santec

Santec Klassica 70847410 User manual

Santec EDO 928460 User manual

Santec

Santec EDO 928460 User manual

Santec CIRC ESTATE 3965CI Series User manual

Santec

Santec CIRC ESTATE 3965CI Series User manual

Santec Lear 2520LA User manual

Santec

Santec Lear 2520LA User manual

Santec LIZA 5161LZ75 User manual

Santec

Santec LIZA 5161LZ75 User manual

Santec E-Series User manual

Santec

Santec E-Series User manual

Santec KATANA E Series User manual

Santec

Santec KATANA E Series User manual

Santec Klassica 9531KT-TM Series User manual

Santec

Santec Klassica 9531KT-TM Series User manual

Santec BRITANI ESTATE 4166IU Series User manual

Santec

Santec BRITANI ESTATE 4166IU Series User manual

Santec ESTATE LYRA 4165TH Series User manual

Santec

Santec ESTATE LYRA 4165TH Series User manual

Santec 3465HO User manual

Santec

Santec 3465HO User manual

Santec Klassica 9531KL-TM Series User manual

Santec

Santec Klassica 9531KL-TM Series User manual

Santec 9566KT40 User manual

Santec

Santec 9566KT40 User manual

Santec Circ 3965CI91 User manual

Santec

Santec Circ 3965CI91 User manual

Santec AVA 9920CU User manual

Santec

Santec AVA 9920CU User manual

Santec KLASSICA 9564KL User manual

Santec

Santec KLASSICA 9564KL User manual

Santec HANA 4165TR Series User manual

Santec

Santec HANA 4165TR Series User manual

Popular Bathroom Fixture manuals by other brands

Insignia Platinum Series installation manual

Insignia

Insignia Platinum Series installation manual

Fleurco Evolution 56307 manual

Fleurco

Fleurco Evolution 56307 manual

Sanela SLU 54GB Instructions for use

Sanela

Sanela SLU 54GB Instructions for use

Noro LOUNGE 0465 Installation

Noro

Noro LOUNGE 0465 Installation

PULSE+ 1055-SSB owner's manual

PULSE+

PULSE+ 1055-SSB owner's manual

Decor Star PL-035-SS manual

Decor Star

Decor Star PL-035-SS manual

Kohler K-1224-HB Roughing-In Guide

Kohler

Kohler K-1224-HB Roughing-In Guide

DURAVIT Happy D.2 Plus HP 4946 Mounting instructions

DURAVIT

DURAVIT Happy D.2 Plus HP 4946 Mounting instructions

Oras Eterna & Natura 6388 Installation and maintenance guide

Oras

Oras Eterna & Natura 6388 Installation and maintenance guide

Häfele 485.60.613 installation manual

Häfele

Häfele 485.60.613 installation manual

Foremost COVE instructions

Foremost

Foremost COVE instructions

Signature Hardware 948956 Install

Signature Hardware

Signature Hardware 948956 Install

Kohler C3-230 quick start guide

Kohler

Kohler C3-230 quick start guide

Whalen LWS60HBVW Assembly instructions

Whalen

Whalen LWS60HBVW Assembly instructions

SANPLAST KN4 installation guide

SANPLAST

SANPLAST KN4 installation guide

Bossini OLE SQUARE E86908 installation instructions

Bossini

Bossini OLE SQUARE E86908 installation instructions

RUBINETTERIE BELLOSTA VIA DELLA SPIGA B3-140/A Installation instruction

RUBINETTERIE

RUBINETTERIE BELLOSTA VIA DELLA SPIGA B3-140/A Installation instruction

KEUCO Edition 400 21533 171351 Instructions for use

KEUCO

KEUCO Edition 400 21533 171351 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.