INDIGO
DIGITAL GLASS-BREAK DETECTOR
indigo_en 03/18
The INDIGO detector enables detection of plate, tempered or laminated glass breaking. This
manual applies to the detector with electronics version 1.4 (or newer).
1. Features
Advanced two-path sound analysis.
Adjustable detection sensitivity.
Supply voltage supervision.
LED indicator.
Tamper protection against cover removal.
2. Specifications
Supply voltage ................................................................................................... 12 V DC ±15%
Standby current consumption .......................................................................................12.5 mA
Maximum current consumption........................................................................................15 mA
Relay contacts rating (resistive load) .............................................................. 40 mA / 16 V DC
Alarm signaling period ..........................................................................................................2s
Detection range .......................................................................................................... up to 6 m
Environmental class according to EN50130-5 ......................................................................... II
Operating temperature range...............................................................................-10°C...+55°C
Maximum humidity.......................................................................................................... 93±3%
Dimensions ......................................................................................................48 x 78 x 24 mm
Weight................................................................................................................................. 48 g
3. Description
Glass-break detection
The detector will report an alarm when it detects a low frequency sound (impact) followed by
a high frequency sound (glass break) in less than 4 seconds. The alarm is signaled by the
alarm output for 2 seconds.
Supply voltage supervision
The detector will report a trouble when the supply voltage drops below 9 V (±5%) for more
than 2 seconds. The trouble results in turning on the alarm output. The alarm output remains
on as long as the trouble exists.