AD-300/AD-301 Networked Hardwired Lock User Guide
TEST LOCK OPERATION
If you encounter problems while performing any of the following tests, review the installation guide
and correct any problems.
Mechanical Test
1. Rotate the inside lever. Operation should be smooth, and the latch should retract.
2. Insert the key into the keyway and rotate the key or the key and lever to open the door. Operation
should be smooth, and the latch should retract.
Electronic Test
Test the AD-300/AD-301 in Factory Default Mode
1. For locks with a keypad, press any number key. The lock should beep.
2. Press the Schlage button. The keypad should light blue for a few seconds.
3. For locks with a card reader, present a credential to the reader. The lock will beep and the left side
of the Schlage button will blink red one time. When the lock is in Factory Default mode and RS-485
is not connected, no credentials are accepted.
4. The AD-300/AD-301 has no default PIN or Programming code. The mechanical key must be
used until the AD-300/AD-301 is in Construction Access Mode, or until the AD-300/AD-301 is
communicating with an access control panel.
Test the AD-300/AD-301 in Construction Access Mode
1. When the Master Construction Credential is presented, the AD-300/AD-301 will beep and the
Schlage button will light green for 20 seconds awaiting the presentation of another credential to be
granted Construction user access.
2. When a valid Construction Access user credential is presented, the lock will unlock for the re-latch
delay period (default three seconds), and the left side of the Schlage button will blink green. When
the lock re-locks after the re-latch delay period, the left side of the Schlage button will blink red.
3. If an invalid Construction Access user credential is presented, the lock will beep and the left side
of the Schlage button will blink red one time. See Construction Access Mode on page 5 for more
information.
! NOTE: Construction Access mode is cancelled when the lock is reset to factory defaults.
When Construction Access mode is cancelled, the Master Construction Credential and all
other credentials added using the Master Construction Credential will no longer function.
Test with the AD-300/AD-301 linked to an Access Control Panel
1. Present a valid credential to the AD-300/AD-301. The Schlage button will blink green, a beep will
sound and the door will unlock for the preset lock delay period. The lock will re-lock after the lock
delay period and the Schlage button will then blink red.
2. If an invalid credential is presented, the Schlage button will blink red, a beep will sound and the
door will not unlock. Credential data for all credentials is reported to the ACP.