Product composition and components Name and function of each part
1. Front Ass`y
2. Back Ass`y
Name Product specication Remark
①
Front Ass`y 88mm(W) X 385mm(H) X 40mm(D) Including rubber pad
② Back Ass`y
88mm(W) X 375mm(H) X 44mm(D)
③
Back bracket 81mm(W) X 319mm(H) X 8.7mm(D)
④ Mortise lock 105.4mm(W) X 240mm(H) X 24mm(D)
⑤ Strike 24mm(W) X 240mm(H) X 4.5mm(D)
⑥ Card key ISO card, Tag key
⑦ Mechanical key 3 EA
⑧ Handle shaft 70.5mm(W) X 8mm(H) X 8mm(D) 40~50mm Door
⑨ Handle shaft(M) 101.7mm(W) X 8mm(H) X 8mm(D) 70~90mm Door
⑩ Key Shaft 1 EA
⑪ Handle shaft stop-ring 2 EA
⑫ Battery 6V (1.5V 'AA' Size LR6 Alkaline, 4ea)
⑬ Screws 1 set
⑭ User manual English Including warranty
form
⑮ Installation template
Using for making hole at the door
⑯ Communication pack
Communication pack
Optional
⑰
Remote key
Remote key Optional
※
Installation condition Door thickness 40~80mm
①
⑥
⑧
⑫
⑨
⑬
Screws
⑭
⑮
User
manual
Installation
template
Remote key Communication pack
⑪
Optional parts
⑯ ⑰
Do not disassemble or alter the lock. Disassembling the
door lock may damage the product. Damages to the
product caused by unauthorized persons may void the
warranty.
If the product generates harmful gases and smoke.
Please remove the batteries immediately from the
product, if you do not take this step immediately, the
product may suffer severe damage.
Please keep the product away from water or any liquids.
If the product is exposed to water or liquids, please wipe
the moisture off with a soft cloth. If moisture or foreign
materials penetrate the product, remove the batteries
immediately.
Please check the batteries every 6 months for leaks/
cleanliness. If leakage is discovered, please wipe out
with a dry cloth and replace with new batteries. In case
of exposure to leakage, wash affected skin area with
soap and water immediately.
Do not clean the product with flammable materials such
as alcohol, benzene or thinners. Such materials may
damage the surface of the lock or cause a fire.
Batteries should not be exposed directly to heat source
or submerged in water, because they may leak or
explode, resulting in severe damage. Do not use
damaged batteries.
Do not allow the battery electrodes to contact metals
such as keys, as the battery may overheat, causing
explosion or severe damage.
Please do not close the door with the deadbolt in the
locked position. It may damage the product or cause a
malfunction.
Do not force to pull the front cover. It may damage the
product or cause a malfunction.
Do not mix old and new batteries, or use different types
of batteries. The battery life is getting shorter and it may
cause leaks or explosion.
Please do not hang the heavy things or bag, etc on
the handle. It is may damage the handle or cause a
malfunction.
Safety precautions Product features
The product can be installed in a left or right handed configuration.
ㆍNormal mode: easy to use for normal user.
ㆍSafety mode: high security mode with manger function added,
provides individual register and delete function which is not
provided in normal mode.
If a high temperature is detected that may cause a fire, the alarm
will ping sound for safety reasons. ( Working temperature : -15~55℃,
Sensor working temperature(high) : 60℃±10℃)
When you enter your home with other people, you may not want to
show PIN code to them. In this case, you may press any numbers
randomly without limitation and then enter your PIN code at the
end.
After multiple incorrect attempted entries an alarm will sound and
all the functions of the lock will be suspended for three minutes. The
alarm activated after three incorrect PIN/card entries.
When the door is opened by force an alarm will sound.
If users do not open the door after unlocking the device it will lock
itself automatically.
When double lock function is activated, the door cannot be opened
from the outside, even with the registered card, PIN code or
fingerprint. Override key can still be used.
Door will not emit any sound when mute is activated.
Factory setting
Item Setting Status Ref.page
Auto/Manual lock mode [Auto lock] 8
Language (English/Chinese) English 5
Normal mode / Security Mode Normal mode 9-10
Voice guide volume (1~3 level) 3 level [Maximum] 7
Beep sound level (1~8 level) 8 level 7
Factory setting PIN code 123456 -
Mute function
Double lock function
Wireless interlock
Battery replacement indicator
Trespass alarm function
Indicate operation status and
checking battery capacity.
Remaining battery 20%
Remaining battery 50%
Remaining battery 80%
Status indicator
Window icon
Handle
You can open the door by pushing or
pulling it
Touch the registered fingerprint on
the sensor to unlock the door
Indicate lock / unlock status
Touch the registered card key to
unlock the door
Override key
Unlock the door with override key manually
When battery does not operate,
product may be operated and
unlocked by contacting a 9V battery
on terminal located outside
You can open the door by pushing
or pulling it
Push up to open the battery cover
Button
Button to lock the door manually
Button
Button to set double locking mode
[N], [S], [ ] Button
⑦
ISO
CARD
Tag
key
⑩
⑤
① ④③②
Notice
Please read this manual before installation and
operation.