AZ 17
Operating instructions
Safety switch
EN 1
1. About this document
1.1 Function
This operating instructions manual provides all the information you
need for the mounting, set-up and commissioning to ensure the safe
operation and disassembly of the safety switchgear. The operating inst-
ructions must be available in a legible condition and a complete version
in the vicinity of the device.
1.2 Target group: authorised qualified personnel
All operations described in this operating instructions manual must
be carried out by trained specialist personnel, authorised by the plant
operator only.
Please make sure that you have read and understood these operating
instructions and that you know all applicable legislations regarding
occupational safety and accident prevention prior to installation and
putting the component into operation.
The machine builder must carefully select the harmonised standards
to be complied with as well as other technical specifications for the
selection, mounting and integration of the components.
1.3 Explanation of the symbols used
Information, hint, note:
This symbol is used for identifying useful additional information.
Caution: Failure to comply with this warning notice could
lead to failures or malfunctions.
Warning: Failure to comply with this warning notice could
lead to physical injury and/or damage to the machine.
1.4 Appropriate use
The products described in these operating instructions are developed to
execute safety-related functions as part of an entire plant or machine. It
is the responsibility of the manufacturer of a machine or plant to ensure
the correct functionality of the entire machine or plant.
The safety switchgear must be exclusively used in accordance with
the versions listed below or for the applications authorised by the
manufacturer. Detailed information regarding the range of applications
can be found in the chapter "Product description".
1.5 General safety instructions
The user must observe the safety instructions in this operating
instructions manual, the country-specific installation standards as well
as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal
catalogues or in the online catalogue on the Internet:
www.schmersal.net.
The information contained in this operating instructions manual is
provided without liability and is subject to technical modifications.
There are no residual risks, provided that the safety instructions as well
as the instructions regarding mounting, commissioning, operation and
maintenance are observed.
1.6 Warning about misuse
In case of improper use or manipulation of the safety switch-
gear, personal hazards or damages to machinery or plant
components cannot be excluded when safety switchgear is
used. The relevant requirements of the standard ISO 14119
must be observed.
Content
1 About this document
1.1 Function ..............................................1
1.2 ..................1
1.3 Explanation of the symbols used ...........................1
1.4 Appropriate use ........................................1
1.5 General safety instructions ...............................1
1.6 Warning about misuse ...................................1
1.7 Exclusion of liability .....................................2
2 Product description
2.1 Ordering code .........................................2
2.2 Special versions........................................2
2.3 Destination and use .....................................2
2.4 Technical data .........................................2
2.5  .....................................2
3 Mounting
3.1 General mounting instructions .............................2
3.2 Dimensions ...........................................3
4 Electrical connection
4.1 General information for electrical connection..................3
4.2 Contact variants........................................3
5 Set-up and maintenance
5.1 Functional testing.......................................3
5.2 Maintenance ..........................................3
6 Disassembly and disposal
6.1 Disassembly...........................................3
6.2 Disposal ..............................................3
7 EU Declaration of conformity
x.000 / 04.2016 / v.A. - 101122006-EN / P / 2016-03-15 / AE-Nr. 5874
EN Operating instructions. . . . . . . . . . . . .pages 1 to 4
Original
2
Operating instructions
Safety switch AZ 17
EN
1.7 Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from
defective mounting or failure to comply with this operating instructions
manual. The manufacturer shall accept no liability for damages resul-
ting from the use of unauthorised spare parts or accessories.
For safety reasons, invasive work on the device as well as arbitrary re-
pairs, conversions and modifications to the device are strictly forbidden;
the manufacturer shall accept no liability for damages resulting from
such invasive work, arbitrary repairs, conversions and/or modifications
to the device.
2. Product description
2.1 Ordering code
This operating instructions manual applies to the following types:
AZ 17-
➀
Z
➁
K-
➂
-
➃
-
➄
No. Option Description
➀
11 1 NO / 1 NC
02 2 NC
➁
Latching force max. 5 N
R Latching force 30 N
➂
M16 cable gland
2243 Frontside cable output
2243-1 Rearside cable output
ST M12 x 1 connector
➃
1637 Gold-plated contacts
➄
5M Cable length 5 m
6M Cable length 6 m
Only if the information described in this operating instructions
manual are realised correctly, the safety function and therefore
the compliance with the Machinery Directive is maintained.
2.2 Special versions
For special versions, which are not listed in the order code below 2.1,
these specifications apply accordingly, provided that they correspond to
the standard version.
2.3 Destination and use
Safety switches with separate actuators AZ 17 are suitable for move-
able safety guards, which need to be closed to ensure the necessary
operational security.
The safety switches are used for applications, in which the hazardous
situation is terminated without delay when the safety guard is opened.
When the safety guard is opened, the NC contacts are positively
opened and the NO contacts are closed.
The safety switchgears are classified according to
ISO 14119 as type 2 switching devices.
The user must evaluate and design the safety chain in
accordance with the relevant standards and the required
safety level.
The entire concept of the control system, in which the safety
component is integrated, must be validated to the relevant
standards.
2.4 Technical data
Standards: IEC 60947-5-1; BG-GS-ET-15
Enclosure: glass-fibre reinforced thermo-
plastic, self-extinguishing
Actuator: stainless steel 1.4301
Coding level according to ISO 14119: low
Protection class: IP67 to IEC 60529
Contact material: Silver
Contact type: change-over with double break Zb,
or 2 NC contacts, galvanically
separated contact bridges
Switching system:
A
acc. IEC 60947-5-1 slow action,
NC contact with positive break
Connection: cut clamp terminals or connector M12, 4-pole
Cable section: 0.75...1.0 mm², flexible
Rated impulse withstand voltage Uimp:4 kV
Rated insulation voltage Ui:250 V
Thermal test current Ithe:10 A
Utilisation category: AC-15
Rated operating current/voltage Ie/Ue:4 A / 230 VAC
Required short-circuit current: 1000 A
Max. fuse rating: 6 A gG D-fuse
Positive break travel: 11 mm
Positive break force: each NC contact 17 N
Ambient temperature: 
Mechanical life: > 1 million operations
Actuating speed: max. 2 m/s
Actuating frequency: max. 2000 operations/h
Latching force: 30 N for ordering suffix R
2.5 Safety classification
Standards: ISO 13849-1
Envisaged structure:
- Basically: applicable up to Cat. 1 / PL c
- With 2-channel usage and
fault exclusion mechanism*: applicable up to Cat. 3 / PL d
with suitable logic unit
B10d NC contact: 2,000,000
B10d NO contact at 10% ohmic contact load: 1,000,000
Service life: 20 years
* If a fault exclusion to the 1-channel mechanics is authorised.
MT
TF
Bdxx
hs/h3600
d
10d op op
op
n
0,1 x nop tcycle
(Determined values can vary depending on the application-specific
parameters hop, dop and tcycle as well as the load.)
If multiple safety components are wired in series, the Performance
Level to ISO 13849-1 will be reduced due to the restricted error
detection under certain circumstances.
3. Mounting
3.1 General mounting instructions
The mounting position however must be chosen so that the ingress of
dirt and soiling in the used opening is avoided. Use the supplied base
plate for the fixing. The tightening torque of the fixing screws must not
exceed 150 Ncm. The enclosure must not be used as an end stop. Any
mounting position. The mounting position however must be chosen so
that the ingress of dirt and soiling in the used opening is avoided. The
unused opening must be sealed by means of slot sealing plugs.
Mounting of the actuators: See mounting instructions actuators.
Please observe the remarks of the standards ISO 12100,
EN 953 and ISO 14119.
3
AZ 17
Operating instructions
Safety switch
EN
The safety component and the actuator must be permanently
fitted to the safety guards and protected against displacement
by suitable measures (tamperproof screws, gluing, drilling,
pinning).
3.2 Dimensions
All measurements in mm.
AZ 17 safety switch
30
22
8
30
M16x1,5
60
5
20
8,2
22
23
31
22
ø 4-8
ø19
24
ø 4,2
4. Electrical connection
4.1 General information for electrical connection
The electrical connection may only be carried out by
authorised personnel in a de-energised condition.
Cut clamp terminals
The IDC method of termination (cut clamp technology) enables

conductor ferrules. To this effect, strip the wire for 17...20 mm and insert
it into the cable gland, close the cable gland, push the conductors in the
groove of the cover (refer to wiring example) and screw the cover back.
Alternatingly tighten the cover screws uniformly. Tightening force for the
Torx T10 cover screws 0.7 ... 1 Nm.
17-20mm
4.2 Contact variants
AZ 17-11ZK
AZ 17-11ZRK
AZ 17-02ZK
AZ 17-02ZRK
13
21
14
22
11
21
12
22
with cable, frontside
AZ-17-11ZK-2243
AZ-17-11ZRK-2243
AZ-17-02ZK-2243
AZ-17-02ZRK-2243
BN 13
BK 21
14 BU
22 GY
BN 11
BK 21
12 BU
22 GY
with cable, rearside
AZ 17-11ZK-2243-1
AZ 17-11ZRK-2243-1
AZ 17-02ZK-2243-1
AZ 17-02ZRK-2243-1
GY 13
BU 21
14 BK
22 BN
GY 11
BU 21
12 BK
22 BN
with connector, A-coding
AZ 17-11ZK-ST
AZ 17-11ZRK-ST
AZ 17-02ZK-ST
AZ 17-02ZRK-ST
12
34
21
13
22
14
12
34
21
11
22
12
5. Set-up and maintenance
5.1 Functional testing
The safety function of the safety components must be tested. The
following conditions must be previously checked and met:
1. Check for correct installation of the actuator and the switch
2. Check the integrity of the cable entry and connections
3. Check the switch enclosure for damage
5.2 Maintenance
In case of correct installation in accordance with the instructions
described above, the component requires little maintenance. For use in
extreme conditions, we recommend routine maintenance including the
following steps:
1. Check for correct installation of the actuator and the switch
2. Remove particles of dust and soiling
3. Check cable entry and connections
Adequate measures must be taken to ensure protection
against tampering either to prevent tampering of the safety
guard, for instance by means of replacement actuators.
Damaged or defective components must be replaced.
6. Disassembly and disposal
6.1 Disassembly
The safety switchgear must be disassembled in a de-energised
condition only.
6.2 Disposal
The safety switchgear must be disposed of in an appropriate manner
in accordance with the national prescriptions and legislations.
4EN
AZ 17-D-EN
Operating instructions
Safety switch AZ 17
7. EU Declaration of conformity
Name of the component: AZ 17
Type: See ordering code
Description of the component: Positive break position switch with
separate actuator for safety functions
Relevant Directives: Machinery Directive
RoHS-Directive
2006/42/EC
2011/65/EU
Applied standards: DIN EN 60947-5-1:2010,
DIN EN ISO 14119:2014
Person authorized for the compilation
of the technical documentation:
Oliver Wacker
Möddinghofe 30
42279 Wuppertal
K. A. Schmersal GmbH & Co. KG
Möddinghofe 30, D - 42279 Wuppertal
Postfach 24 02 63, D - 42232 Wuppertal
Phone: +49 - (0)2 02 - 64 74 - 0
Telefax: +49 - (0)2 02 - 64 74 - 1 00
E-Mail: [email protected]
Internet: http://www.schmersal.com
Place and date of issue: Wuppertal, March 14, 2016
Authorised signature
Philip Schmersal
Managing Director
EU Declaration of conformity
Original K.A. Schmersal GmbH & Co. KG
Möddinghofe 30
42279 Wuppertal
Germany
Internet: www.schmersal.com
We hereby certify that the hereafter described components both in their basic design and construction conform
to the applicable European Directives.
The currently valid declaration of conformity can be
downloaded from the internet at www.schmersal.net.

This manual suits for next models

15

Other schmersal Switch manuals

schmersal T3Z 068 Series User manual

schmersal

schmersal T3Z 068 Series User manual

schmersal AZ 200 T User manual

schmersal

schmersal AZ 200 T User manual

schmersal AZM300B-ST-1P2P-N User manual

schmersal

schmersal AZM300B-ST-1P2P-N User manual

schmersal TFH 232-11UEDR User manual

schmersal

schmersal TFH 232-11UEDR User manual

schmersal AZ 415 Series User manual

schmersal

schmersal AZ 415 Series User manual

schmersal SHGV User manual

schmersal

schmersal SHGV User manual

schmersal AZM300 User manual

schmersal

schmersal AZM300 User manual

schmersal TESK Series User manual

schmersal

schmersal TESK Series User manual

schmersal AZ 415-33ZPK User manual

schmersal

schmersal AZ 415-33ZPK User manual

schmersal AZM300B-I2-ST1P2P-DU Parts list manual

schmersal

schmersal AZM300B-I2-ST1P2P-DU Parts list manual

schmersal TQ 900 User manual

schmersal

schmersal TQ 900 User manual

schmersal AZ 415-33ZPDK User manual

schmersal

schmersal AZ 415-33ZPDK User manual

schmersal TZG User manual

schmersal

schmersal TZG User manual

schmersal EX-Z 355 Series User manual

schmersal

schmersal EX-Z 355 Series User manual

schmersal AZM300B-I2-ST-1P2P-A-DU User manual

schmersal

schmersal AZM300B-I2-ST-1P2P-A-DU User manual

schmersal TV.S 355 User manual

schmersal

schmersal TV.S 355 User manual

schmersal AZM400Z-ST-I2-1P2P-BOW User manual

schmersal

schmersal AZM400Z-ST-I2-1P2P-BOW User manual

schmersal TQ 700 S User manual

schmersal

schmersal TQ 700 S User manual

schmersal BNS-B20 User manual

schmersal

schmersal BNS-B20 User manual

schmersal AZM 200 D User manual

schmersal

schmersal AZM 200 D User manual

schmersal AZM300B-I1-ST-1P2P Operation and maintenance manual

schmersal

schmersal AZM300B-I1-ST-1P2P Operation and maintenance manual

schmersal EX-AZ 415 User manual

schmersal

schmersal EX-AZ 415 User manual

schmersal ZSD5 User manual

schmersal

schmersal ZSD5 User manual

schmersal AZM 161 Series User manual

schmersal

schmersal AZM 161 Series User manual

Popular Switch manuals by other brands

ATEN VE3912T user manual

ATEN

ATEN VE3912T user manual

Linksys FENSK05 - EtherFast Network Starter Specifications

Linksys

Linksys FENSK05 - EtherFast Network Starter Specifications

Enterasys Matrix-V V2H124-24FX Quick reference guide

Enterasys

Enterasys Matrix-V V2H124-24FX Quick reference guide

HP StorageWorks 2/16 - SAN Switch Installation

HP

HP StorageWorks 2/16 - SAN Switch Installation

Dynaudio Xeo owner's manual

Dynaudio

Dynaudio Xeo owner's manual

Calibre HQPro1000 user guide

Calibre

Calibre HQPro1000 user guide

ANTAIRA LMP-1002G-10G-SFP-24 Hardware manual

ANTAIRA

ANTAIRA LMP-1002G-10G-SFP-24 Hardware manual

Hawking PN500TPA Specifications

Hawking

Hawking PN500TPA Specifications

Somerdata E1UC-4 Installation and operation

Somerdata

Somerdata E1UC-4 Installation and operation

FAAC XK 21 L quick start guide

FAAC

FAAC XK 21 L quick start guide

LEGRAND Valena 7 418 07A manual

LEGRAND

LEGRAND Valena 7 418 07A manual

AVGear AVG-SC51T user manual

AVGear

AVGear AVG-SC51T user manual

Dell PowerConnect 3424 user guide

Dell

Dell PowerConnect 3424 user guide

Eaton STS 16 Installation and user manual

Eaton

Eaton STS 16 Installation and user manual

Pilz PSEN cs3.1a/p/M12 operating instructions

Pilz

Pilz PSEN cs3.1a/p/M12 operating instructions

SMC Networks EZ Net 16SW EZNET-16SW Specification sheet

SMC Networks

SMC Networks EZ Net 16SW EZNET-16SW Specification sheet

Pilz PSEN ma1.4p-57 operating instructions

Pilz

Pilz PSEN ma1.4p-57 operating instructions

Kramer VP-740 ProScale quick guide

Kramer

Kramer VP-740 ProScale quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.