manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sealey
  6. •
  7. Controllers
  8. •
  9. Sealey SA4FR/38 User manual

Sealey SA4FR/38 User manual

This manual suits for next models

1

Other Sealey Controllers manuals

Sealey REG/MM User manual

Sealey

Sealey REG/MM User manual

Sealey SA2001 User manual

Sealey

Sealey SA2001 User manual

Sealey SUPERSTART220.V3 User manual

Sealey

Sealey SUPERSTART220.V3 User manual

Sealey ECS350 User manual

Sealey

Sealey ECS350 User manual

Sealey ARD01.V2 User manual

Sealey

Sealey ARD01.V2 User manual

Sealey SA2FR.V3 User manual

Sealey

Sealey SA2FR.V3 User manual

Sealey SGA4 User manual

Sealey

Sealey SGA4 User manual

Sealey SA2FR.V3 User manual

Sealey

Sealey SA2FR.V3 User manual

Sealey SA206 User manual

Sealey

Sealey SA206 User manual

Sealey SGA40 User manual

Sealey

Sealey SGA40 User manual

Sealey SA106 User manual

Sealey

Sealey SA106 User manual

Sealey SGA3.V2 User manual

Sealey

Sealey SGA3.V2 User manual

Sealey SGA4.V2 User manual

Sealey

Sealey SGA4.V2 User manual

Sealey REG/MO.V2 User manual

Sealey

Sealey REG/MO.V2 User manual

Sealey SGA30 User manual

Sealey

Sealey SGA30 User manual

Sealey REG/MM.V2 User manual

Sealey

Sealey REG/MM.V2 User manual

Sealey SGA4.V2 User manual

Sealey

Sealey SGA4.V2 User manual

Sealey START800 User manual

Sealey

Sealey START800 User manual

Sealey SUPERBOOST 140.V4 User manual

Sealey

Sealey SUPERBOOST 140.V4 User manual

Sealey SUPERBOOST 180.V5 User manual

Sealey

Sealey SUPERBOOST 180.V5 User manual

Sealey SUPERSTART300.V5 User manual

Sealey

Sealey SUPERSTART300.V5 User manual

Sealey ELECTROSTART E/START3012 User manual

Sealey

Sealey ELECTROSTART E/START3012 User manual

Sealey ElectroStart 300.V2 User manual

Sealey

Sealey ElectroStart 300.V2 User manual

Sealey ARD01 User manual

Sealey

Sealey ARD01 User manual

Popular Controllers manuals by other brands

Sunricher SR-ZV9003T3-RGBW-US Installation

Sunricher

Sunricher SR-ZV9003T3-RGBW-US Installation

Ksenia intro Installation and configuration manual

Ksenia

Ksenia intro Installation and configuration manual

Inovance CAN200 Series manual

Inovance

Inovance CAN200 Series manual

Gauzy LC6 FLEX Controller Installation and operation guide

Gauzy

Gauzy LC6 FLEX Controller Installation and operation guide

Viking SLP-1 Technical practice

Viking

Viking SLP-1 Technical practice

CKD KBX-30E-U Series instruction manual

CKD

CKD KBX-30E-U Series instruction manual

Sharp Energy Sun Flux User manual & installation guide

Sharp Energy

Sharp Energy Sun Flux User manual & installation guide

Yamaha RCX40 user manual

Yamaha

Yamaha RCX40 user manual

AB Quality PowerFlex 400 Frames D-H Service bulletin

AB Quality

AB Quality PowerFlex 400 Frames D-H Service bulletin

Yamaha MJC8 owner's manual

Yamaha

Yamaha MJC8 owner's manual

AL-KO ATC operating instructions

AL-KO

AL-KO ATC operating instructions

Savant SmartControl 2 Deployment guide

Savant

Savant SmartControl 2 Deployment guide

GameSir T3S user manual

GameSir

GameSir T3S user manual

Kostal inveor operating manual

Kostal

Kostal inveor operating manual

Emerson Yarway 20-55 Operating and safety instructions

Emerson

Emerson Yarway 20-55 Operating and safety instructions

CoCo ACM-LV24 Quick installation guide

CoCo

CoCo ACM-LV24 Quick installation guide

Brooks SLA5810/20 Installation and operation manual

Brooks

Brooks SLA5810/20 Installation and operation manual

SIGMA TEK SR 011 Technical manual

SIGMA TEK

SIGMA TEK SR 011 Technical manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Instructions for:
FILTER/REGULATOR - SA4FR/38
REGULATOR - SA5/RG/14
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT:PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
pWARNING! Ensure that Health & Safety, local authority, and general workshop practice
regulations are adhered to when using this equipment.
pWARNING! Disconnect the equipment from the air supply before changing accessories,
servicing or performing any maintenance.
3Keep the equipment clean and maintain it in good condition (use an authorised service agent).
3Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
pWARNING! Ensure that the correct air pressure is maintained and not exceeded.
3Keep air hoses away from heat, oil and sharp edges. Check air hoses for wear before each
use and ensure that all connections are secure.
7DO NOT direct air from the air hose at yourself, others or animals.
3Drain the compressor air tank daily. Water in the air line will damage equipment.
3When work is complete ensure that the air supply is turned off.
Heavy-duty aluminium alloy valve assemblies with large gauges dual marked in psi and bar. Pressure control knob can be locked
in position to prevent accidental alteration. SA4FR/38 features integral filter. Air outlets are fitted with shut-off valves.
2. INTRODUCTION & SPECIFICATIONS
SA4FR/38 SA5/RG/14
Max. inlet/output pressure - psi/bar . . . . . . . . . . 174/12. . . . . . . . . . . . . . . 174/12
Working pressure range - psi/bar. . . . . . . . . 30-120/2-8 . . . . . . . . . . . 30-120/2-8
Max. flow rate - cfm . . . . . . . . . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . . . 76
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8BSP(M) . . . . . . . . . . . 1/4BSP(F)
Outlet. . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 1/4BSP(M) . . . . . . . . 1 x 1/4BSP(M)
3. CONTENT & INSTALLATION
3.1. Confirm that all items are present and undamaged. If any parts are missing or damaged please contact the supplier.
SA4FR/38 - Combined filter/regulator with gauge.
SA5/RG/14 - Regulator and gauge.
3.2. Fig.1 shows a typical air line installation. The filter is located
upstream of the regulator - unless combined - and the
lubricator downstream.
3.2.1. When installing the filter/regulator or regulator ensure that:
a) Gauge is visible
b) Regulator control is accessible
c) Flow direction arrow (SA5/RG/14) matches system air flow.
SA4FR/38 The inlet on is at the base of the filter body and the
outlets are either side of the gauge.
SA5/RG/14 The inlet and outlet are on the sides of the body
with the gauge between them.
Note: To ensure air-tight joints use PTFE tape.
fig. 1
SA4FR/38
SA5/RG/14
SA4FR/38 & SA5/RG/14 - 1 - 041102
Instructions for:
FILTER/REGULATOR - SA4FR/38
REGULATOR - SA5/RG/14
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according
to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT:PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS AND CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
pWARNING! Ensure that Health & Safety, local authority, and general workshop practice
regulations are adhered to when using this equipment.
pWARNING! Disconnect the equipment from the air supply before changing accessories,
servicing or performing any maintenance.
3Keep the equipment clean and maintain it in good condition (use an authorised service agent).
3Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
pWARNING! Ensure that the correct air pressure is maintained and not exceeded.
3Keep air hoses away from heat, oil and sharp edges. Check air hoses for wear before each
use and ensure that all connections are secure.
7DO NOT direct air from the air hose at yourself, others or animals.
3Drain the compressor air tank daily. Water in the air line will damage equipment.
3When work is complete ensure that the air supply is turned off.
Heavy-duty aluminium alloy valve assemblies with gauges dual marked in psi and bar. Pressure control knob can be locked in
position to prevent accidental alteration. SA4FR/38 features integral filter. Air outlets are fitted with shut-off valves.
2. INTRODUCTION & SPECIFICATIONS
SA4FR/38 SA5/RG/14
Max. inlet/output pressure - psi/bar . . . . . . . . . . 174/12. . . . . . . . . . . . . . . 174/12
Working pressure range - psi/bar. . . . . . . . . 30-120/2-8 . . . . . . . . . . . 30-120/2-8
Max. flow rate - cfm . . . . . . . . . . . . . . . . . . . . . . . . 76 . . . . . . . . . . . . . . . . . . 76
Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/8BSP(M) . . . . . . . . . . . 1/4BSP(F)
Outlet. . . . . . . . . . . . . . . . . . . . . . . . . . 2 x 1/4BSP(M) . . . . . . . . 1 x 1/4BSP(M)
3. CONTENT & INSTALLATION
3.1. Confirm that all items are present and undamaged. If any parts are missing or damaged please contact the supplier.
SA4FR/38 - Combined filter/regulator with gauge.
SA5/RG/14 - Regulator and gauge.
3.2. Fig.1 shows a typical air line installation. The filter is located
upstream of the regulator - unless combined - and the
lubricator downstream.
3.2.1. When installing the filter/regulator or regulator ensure that:
a) Gauge is visible
b) Regulator control is accessible
c) Flow direction arrow (SA5/RG/14) matches system air flow.
SA4FR/38 The inlet on is at the base of the filter body and the
outlets are either side of the gauge.
SA5/RG/14 The inlet and outlet are on the sides of the body
with the gauge between them.
Note: To ensure air-tight joints use PTFE tape.
fig. 1
SA4FR/38
SA5/RG/14
SA4FR/38 & SA5/RG/14 - 1 - 041102
SA4FR/38 & SA5/RG/14 - 1 - 041102
4. OPERATION
4.1. Regulator - The output pressure control knob must be lifted before turning. Turn clockwise to increase and anticlockwise
to reduce pressure. The output pressure will be shown on the gauge. When the required pressure is achieved push down
control knob to lock and prevent inadvertent alteration. When setting output pressure always adjust up from a lower pressure.
4.2. Filter (SA4FR/38) - The filter should be cleaned regularly. Unscrew the filter housing from the regulator body to access the filter.
5. ADDITIONAL FITTINGS
6. DECLARATION OF CONFORMITY
The following fittings are available from your supplier:
SA1/1212...................1/2BSP(M)-1/2BSP(M) nipple SA1/1238F ...............1/2BSPT(M)-3/8BSP(F) reducer
SA1/1214F ............1/2BSPT(M)-1/4BSP(F) reducer SA1/3814F ...............3/8BSPT(M)-1/4BSP(F) reducer
SA1/1414 ..............1/4BSPT(M)-1/4BSPT(M) nipple
01284 757500 sales@sealey.co.uk www.sealey.co.uk
01284 703534
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component
parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address,
including postcode.
Declaration of Conformity We, the sole importer into the UK, declare that the products listed here are in
conformity with the following standards and directives.
The construction files for these products are held by the manufacturer and
may be inspected, by a national authority, upon request to Jack Sealey Ltd.
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
Filter/Regulator, Model: SA4FR/38
Regulator, Model: SA5/RG/14
97/23/EC Pressure Equipment Directive
98/37/EC Machinery Directive
Signed by Mark Sweetman 5th November 2002
Sole UK Distributor, Sealey Group,
Bury St. Edmunds, Suffolk.
e-mail
Web
SA4FR/38 & SA5/RG/14 - 1 - 041102
4. OPERATION
4.1. Regulator - The output pressure control knob must be lifted before turning. Turn clockwise to increase and anticlockwise
to reduce pressure. The output pressure will be shown on the gauge. When the required pressure is achieved push down
control knob to lock and prevent inadvertent alteration. When setting output pressure always adjust up from a lower pressure.
4.2. Filter (SA4FR/38) - The filter should be cleaned regularly. Unscrew the filter housing from the regulator body to access the filter.
5. ADDITIONAL FITTINGS
6. DECLARATION OF CONFORMITY
The following fittings are available from your supplier:
SA1/1212...................1/2BSP(M)-1/2BSP(M) nipple SA1/1238F ...............1/2BSPT(M)-3/8BSP(F) reducer
SA1/1214F ............1/2BSPT(M)-1/4BSP(F) reducer SA1/3814F ...............3/8BSPT(M)-1/4BSP(F) reducer
SA1/1414 ..............1/4BSPT(M)-1/4BSPT(M) nipple
01284 757500 sales@sealey.co.uk www.sealey.co.uk
01284 703534
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component
parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address,
including postcode.
Declaration of Conformity We, the sole importer into the UK, declare that the products listed here are in
conformity with the following standards and directives.
The construction files for these products are held by the manufacturer and
may be inspected, by a national authority, upon request to Jack Sealey Ltd.
For Jack Sealey Ltd. Sole importer into the UK of Sealey Power Products.
Filter/Regulator, Model: SA4FR/38
Regulator, Model: SA5/RG/14
97/23/EC Pressure Equipment Directive
98/37/EC Machinery Directive
Signed by Mark Sweetman 5th November 2002
Sole UK Distributor, Sealey Group,
Bury St. Edmunds, Suffolk.
e-mail
Web